      Comparison of surgical repositioning rates and outcomes for hydrophilic vs hydrophobic single-piece acrylic toric IOLs

      , , ,
      Journal of Cataract and Refractive Surgery
      Ovid Technologies (Wolters Kluwer Health)

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Related collections

          Most cited references19

          • Record: found
          • Abstract: found
          • Article: not found

          Toric intraocular lenses: historical overview, patient selection, IOL calculation, surgical techniques, clinical outcomes, and complications.

          We present an overview of currently available toric intraocular lenses (IOLs) and multifocal toric IOLs. Relevant patient selection criteria, IOL calculation issues, and surgical techniques for IOL implantation are discussed. Clinical outcomes including uncorrected visual acuity, residual refractive astigmatism, and spectacle independency, which have been reported for both toric IOLs and multifocal toric IOLs, are reviewed. The incidence of misalignment, the most important complication of toric IOLs, is determined. Finally, future developments in the field of toric IOLs are discussed.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            The AcrySof Toric intraocular lens in subjects with cataracts and corneal astigmatism: a randomized, subject-masked, parallel-group, 1-year study.

            To compare the AcrySof Toric intraocular lens (IOL) and an AcrySof spherical control IOL and to investigate rotational stability of the AcrySof Toric IOL (Alcon Laboratories, Inc., Fort Worth, TX) in subjects with cataracts and preexisting corneal astigmatism. Randomized, subject-masked, parallel-group, multicenter, 1-year study. We included 517 subjects (Toric IOL, n = 256; control IOL, n = 261). Unilateral implantation of an AcrySof Toric or AcrySof spherical control IOL (spherical powers, 12.00-25.00 diopters [D]; cylinder powers 1.50, 2.25, or 3.00 D for corneal astigmatism correction of 0.75 to < 1.50, ≥ 1.50 to <2.00, and ≥ 2.00 D with no upper limit, respectively). No limbal relaxing incisions were permitted. Visual acuity outcomes, IOL position, patient-reported spectacle use, and safety. One year postoperatively, best spectacle-corrected distance visual acuity of ≥ 20/20 was 77.7% (Toric IOL) versus 69.2% (control IOL). Uncorrected distance visual acuity of 20/20 or better was 40.7% (Toric IOL) versus 19.4% (control IOL; P<0.05). Mean absolute residual refractive cylinder was 0.59 D (Toric IOL) versus 1.22 D (control IOL; P<0.0001). Mean rotation was < 4° (range, 0°-20°) for the Toric IOL. Six-month spectacle freedom was 61.0% (Toric IOL) and 36.4% (control IOL; P < 0.0001). Complications in both groups were few and were as would be expected with cataract surgery. Favorable efficacy, rotational stability, distance vision spectacle freedom, and safety results support the use of the AcrySof Toric IOL for patients with cataracts and corneal astigmatism. Proprietary or commercial disclosure may be found after the references. Copyright © 2010 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found
              Is Open Access

              Toric Intraocular Lenses in the Correction of Astigmatism During Cataract Surgery: A Systematic Review and Meta-analysis.

              We performed a systematic review and meta-analysis to evaluate the benefit and harms associated with implantation of toric intraocular lenses (IOLs) during cataract surgery. Outcomes were postoperative uncorrected distance visual acuity (UCDVA) and distance spectacle independence. Harms were evaluated as surgical complications and residual astigmatism.
                Bookmark

                Author and article information

                Journal
                Journal of Cataract and Refractive Surgery
                J Cataract Refract Surg
                Ovid Technologies (Wolters Kluwer Health)
                0886-3350
                1873-4502
                2021
                February 2021
                : 47
                : 2
                : 178-183
                Article
                10.1097/j.jcrs.0000000000000415
                32925653
                3120b72b-2249-45c2-a5ab-37ef8e44f9b8
                © 2021
                History

                Comments

                Comment on this article