      New In Vivo Measurements of Pressures in the Intervertebral Disc in Daily Life :

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          We conducted intradiscal pressure measurements with one volunteer performing various activities normally found in daily life, sports, and spinal therapy. The goal of this study was to measure intradiscal pressure to complement earlier data from Nachemson with dynamic and long-term measurements over a broad range of activities. Loading of the spine still is not well understood. The most important in vivo data are from pioneering intradiscal pressure measurements recorded by Nachemson during the 1960s. Since that time, there have been few data to corroborate or dispute those findings. Under sterile surgical conditions, a pressure transducer with a diameter of 1.5 mm was implanted in the nucleus pulposus of a nondegenerated L4-L5 disc of a male volunteer 45-years-old and weighing 70 kg. Pressure was recorded with a telemetry system during a period of approximately 24 hours for various lying positions; sitting positions in a chair, in an armchair, and on a pezziball (ergonomic sitting ball); during sneezing, laughing, walking, jogging, stair climbing, load lifting during hydration over 7 hours of sleeping, and others. The following values and more were measured: lying prone, 0.1 MPa; lying laterally, 0.12 MPa; relaxed standing, 0.5 MPa; standing flexed forward, 1.1 MPa; sitting unsupported, 0.46 MPa; sitting with maximum flexion, 0.83 MPa; nonchalant sitting, 0.3 MPa; and lifting a 20-kg weight with round flexed back, 2.3 MPa; with flexed knees, 1.7 MPa; and close to the body, 1.1 MPa. During the night, pressure increased from 0.1 to 0.24 MPa. Good correlation was found with Nachemson's data during many exercises, with the exception of the comparison of standing and sitting or of the various lying positions. Notwithstanding the limitations related to the single-subject design of this study, these differences may be explained by the different transducers used. It can be cautiously concluded that the intradiscal pressure during sitting may in fact be less than that in erect standing, that muscle activity increases pressure, that constantly changing position is important to promote flow of fluid (nutrition) to the disc, and that many of the physiotherapy methods studied are valid, but a number of them should be re-evaluated.

          Related collections

          Most cited references19

          • Record: found
          • Abstract: found
          • Article: not found

          Hip joint loading during walking and running, measured in two patients.

          The resultant hip joint force, its orientation and the moments were measured in two patients during walking and running using telemetering total hip prostheses. One patient underwent bilateral joint replacement and a second patient, additionally suffering from a neuropathic disease and atactic gait patterns, received one instrumented hip implant. The joint loading was observed over the first 30 and 18 months, respectively, following implantation. In the first patient the median peak forces increased with the walking speed from about 280% of the patient's body weight (BW) at 1 km h-1 to approximately 480% BW at 5 km h-1. Jogging and very fast walking both raised the forces to about 550% BW; stumbling on one occasion caused magnitudes of 720% BW. In the second patient median forces at 3 km h-1 were about 410% BW and a force of 870% BW was observed during stumbling. During all types of activities, the direction of the peak force in the frontal plane changed only slightly when the force magnitude was high. Perpendicular to the long femoral axis, the peak force acted predominantly from medial to lateral. The component from ventral to dorsal increased at higher force magnitudes. In one hip in the first patient and in the second patient the direction of large forces approximated the average anteversion of the natural femur. The torsional moments around the stem of the implant were 40.3 N m in the first patient and 24 N m in the second.
            Bookmark
            • Record: found
            • Abstract: not found
            • Article: not found

            Disc Pressure Measurements

              Bookmark
              • Record: found
              • Abstract: not found
              • Article: not found

              In Vivo Measurements of Intradiscal Pressure

                Bookmark

                Author and article information

                Journal
                Spine
                Spine
                Ovid Technologies (Wolters Kluwer Health)
                0362-2436
                1999
                April 1999
                : 24
                : 8
                : 755-762
                Article
                10.1097/00007632-199904150-00005
                10222525
                33ccb3b9-3570-4593-b36c-4766dc5dbe3d
                © 1999
                History

                Comments

                Comment on this article