      Helical tomotherapy for locoregional irradiation including the internal mammary chain in left-sided breast cancer: dosimetric evaluation.

      Radiotherapy and Oncology
      Breast Neoplasms, pathology, radiotherapy, Dose Fractionation, Female, Humans, Lymph Nodes, radiation effects, Neoplasm Staging, Radiotherapy Dosage, Radiotherapy Planning, Computer-Assisted, methods, Radiotherapy, Computer-Assisted, Radiotherapy, Intensity-Modulated, Treatment Outcome

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          To compare a standard 3- or 4-field technique to intensity modulated radiotherapy with helical tomotherapy (IMRT-HT) in the planning of locoregional breast radiation including the internal mammary chain (IMC). For 10 women with stage III left-sided breast cancer with a planning target volume (PTV) defined by the breast/chest wall and regional nodes, radiotherapy to a dose of 50 Gy in 25 fractions was planned using a standard 3- or 4-field technique and using IMRT-HT. Various metrics were extracted from dose-volume histograms, and were compared using the paired Student's t-test. The PTV receiving at least 95% of the prescribed dose did not differ between the two plans, but the VD115% was significantly lower with IMRT-HT. The dose conformality was significantly better with IMRT-HT. The cardiac V30(Gy) was reduced with IMRT-HT. The mean lungs dose was lower with IMRT-HT, as well the V20(Gy). With IMRT-HT, a greater volume of contralateral breast was irradiated to 5 Gy, but a smaller volume of soft tissue received dose above 50 Gy. Compared to a standard technique, IMRT-HT provides similar target coverage, improves dose conformality and dose homogeneity within the PTV, decreases mean lung dose and spares heart, lung and soft tissue from high dose exposure.

          Related collections

          Author and article information

          Comments

          Comment on this article

          scite_

          Similar content302

          Cited by18