      THERMAL PERFORMANCE OF GREEN ROOF PANELS IN SUB-ZERO TEMPERATURES

      research-article

      Read this article at

      ScienceOpenPublisher
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          To date, much of the research on green roof technology has focused on the capacity for these systems to contribute to the cooling of buildings during summer months. The thermal performance of green roofs in cold climate conditions is critical to understanding the potential of these roofs to decrease energy use in buildings during winter. This paper compares the behavior of two green roof systems with that of a conventional built-up roof by making use of a novel hot box testing apparatus.

          The green roofs tested are classified as extensive systems. Each system included: a 3 mm thick styrene butadiene rubber waterproofing membrane, 0.2 mm thick polyethylene slip sheet, a 76 mm thick extruded polystyrene insulation layer, 2 mm thick filter fabric, a 51 mm drainage layer followed by a 2 mm thick filter cloth, either 100 mm or 150 mm growing medium, and a 25 mm thick wild flower vegetated mat. The conventional roof consisted of a 2 mm thick layer of Kraft vapour retarder bonded with insulation adhesive, 51 mm of isocyanurate insulation, 25 mm of fibreboard, a three ply (2 mm) cold-applied built-up roof membrane, and a gravel ballast finish 51 mm thick.

          Each roof was subjected to temperatures between 0°C and −25°C, while the temperature within the hot box was held at 21°C. The effect of vegetation on a green roof to reduce wind speeds or increase snow cover were not considered in this study. The power required, as well as the temperatures throughout each system at steady state conditions, were monitored for 5 hours. The data collected from thermal testing suggests that the R-value of green roofs with 100 mm or 150 mm thick layers of growing medium is 37% higher than a conventional roof when subjected to temperatures of 0°C to −25°C.

          Related collections

          Most cited references8

          • Record: found
          • Abstract: not found
          • Article: not found

          A green roof model for building energy simulation programs

            Bookmark
            • Record: found
            • Abstract: not found
            • Article: not found

            Analysis of the green roof thermal properties and investigation of its energy performance

              Bookmark
              • Record: found
              • Abstract: not found
              • Article: not found

              Quantifying the effect of slope on extensive green roof stormwater retention

                Bookmark

                Author and article information

                Journal
                jgrb
                Journal of Green Building
                College Publishing
                1552-6100
                1943-4618
                1943-4618
                Spring 2010
                : 5
                : 2
                : 91-104
                Author notes

                1Engineer, Turner Construction, Washington, D.C.

                2Reader, Arup/RAEng Senior Research Fellow in Structures in Fire Institute for Infrastructure & Environment, William Rankine Building, The School of Engineering and Electronics, The University of Edinburgh, The King's Buildings, Mayfield Road, Edinburgh, EH9 3JL, Tel: 0131 650 5710, Email: luke.bisby@ 123456ed.ac.uk .

                3Professor, Department of Civil Engineering, Queen's University, Kingston, Ontario, Canada, K7L 3N6, Tel: 613-533-2469.

                4Associate Professor and Corresponding Author, Department of Civil Engineering, Queen's University, Kingston, Ontario, Canada, K7L 3N6, Tel: 613-533-2469, Email: colin@ 123456civil.queensu.ca .

                Article
                jgb.5.2.91
                10.3992/jgb.5.2.91
                390f750d-6f07-4068-ac5f-deb773288a03
                ©2010 by College Publishing. All rights reserved.

                Volumes 1-7 of JOGB are open access and do not require permission for use, though proper citation should be given. To view the licenses, visit https://creativecommons.org/licenses/by-nc/4.0/

                History
                Page count
                Pages: 14
                Categories
                RESEARCH ARTICLES

                Urban design & Planning,Civil engineering,Environmental management, Policy & Planning,Architecture,Environmental engineering
                green roofs,R-value,thermal performance,low temperature,hot box tests

                Comments

                Comment on this article