      Complications after percutaneous internal fixator for anterior pelvic ring injuries

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Related collections

          Most cited references27

          • Record: found
          • Abstract: not found
          • Article: not found

          Fracture and Dislocation Classification Compendium - 2007

            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Single-incision anterior approach for total hip arthroplasty on an orthopaedic table.

            Dislocation remains the leading early complication of total hip arthroplasty; surgical approach and implant positioning have been recognized as factors influencing total hip arthroplasty stability. We describe a total hip arthroplasty technique done through a single, tissue sparing anterior approach that allows implantation of the femoral and acetabular components without detaching or sectioning any of the muscles and tendons around the hip joint. A series of 437 consecutive, unselected patients who had 494 primary total hip arthroplasty surgeries done through an anterior approach on an orthopaedic table from September 1996 to September 2004 was reviewed. There were 54 hybrid and 442 uncemented hips in the 437 patients (57 bilateral). The average patient age was 64 years. Radiographic analysis showed an average abduction angle of 42 degrees , with 96% in the range of 35 degrees to 50 degrees abduction. The average cup anteversion was 19 degrees with 93% within the target range of 10 degrees to 25 degrees . Postoperative leg length discrepancy averaged 3 +/- 2 mm (range, 0-26 mm). Three patients sustained dislocations for an overall dislocation rate of 0.61%, and no patients required revision surgery for recurrent dislocation. There were 17 operative complications, including one deep infection, three wound infections, one transient femoral nerve palsy, three greater trochanter fracture, two femoral shaft fractures four calcar fractures, and three ankle fractures. Operative time averaged 75 minutes (range 40-150 minutes), and the average blood loss was 350 mL (range, 100-1300 mL). The mean hospital stay was 3 days (range, 1-17 days). The anterior approach on the orthopaedic table is a minimally invasive technique applicable to all primary hip patients. This technique allows accurate and reproducible component positioning and leg-length restoration and does not increase the rate of hip dislocation. Therapeutic study, Level IV-1 (case series). See the Guidelines for Authors for a complete description of levels of evidence.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Treatment of unstable pelvic ring injuries with an internal anterior fixator and posterior fixation: initial clinical series.

              To present a novel internal fixation device for stabilizing unstable pelvic fractures using supra-acetabular spinal pedicle screws and a subcutaneous connecting rod (INFIX). Level I trauma center. Case series. Twenty-four patients with rotational or vertically unstable pelvic fractures that reported to a level I trauma center. METHODS/INTERVENTION: Surgical treatment of unstable pelvic fractures included reduction, appropriate posterior fixation where indicated, and an anterior subcutaneous internal fixator. Healing time, quality and loss of reduction, ease of nursing, incidence of complications, including nonunion, infection, and patient mobility and comfort. In the present clinical series, all fractures healed without significant loss of reduction. There were no infections, delayed unions or nonunions. Nursing care was observed to be easier especially in the intensive care unit setting. Complications included unilateral anterior thigh paresthesias in 2 patients, and 1 patient each required repositioning of the pedicle screw and readjustment of screw rod junction. Patients tolerated the procedure well and were fairly mobile after the procedure. The reported technique allows for a definitive and stable anterior fixation of vertically and rotationally unstable pelvic fractures when combined with the appropriate posterior fixation if indicated. The potential complications are acceptable with this technique and good outcomes were achieved. A second operative procedure is required for removal of the device. It is our view that its best indication is in obese individuals, in whom other options have shortcomings.
                Bookmark

                Author and article information

                Journal
                International Orthopaedics
                International Orthopaedics (SICOT)
                Springer Science and Business Media LLC
                0341-2695
                1432-5195
                September 2017
                February 24 2017
                September 2017
                : 41
                : 9
                : 1785-1790
                Article
                10.1007/s00264-017-3415-4
                28236073
                39ea1aa2-e476-4146-97b6-291b208da810
                © 2017

                http://www.springer.com/tdm

                History

                Comments

                Comment on this article