      Influence of Shod and Barefoot Running on the In Vivo Kinematics of the First Metatarsophalangeal Joint

      research-article

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          The biomechanics of the first metatarsophalangeal joint (MTPJ) is affected by different shoe conditions. In the biomechanical research field, traditional skin marker motion capture cannot easily acquire the in vivo joint kinematics of the first MTPJ in shoes. Thus, the present study aims to investigate the differences of the first MTPJ’s six-degree-of-freedom (6DOF) kinematics between shod and barefoot running by using a high-speed dual fluoroscopic imaging system (DFIS). In total, 15 healthy male runners were recruited. Computed tomography scans were taken from each participant’s right foot for the construction of 3D models and local coordinate systems. Radiographic images were acquired at 100 Hz while the participants ran at a speed of 3 m/s ± 5% in shod and barefoot conditions along an elevated runway, and 6DOF kinematics of the first MTPJ were calculated by 3D–2D registration. Paired sample t-tests were used to compare the kinematic characteristics of the first MTPJ 6DOF kinematics during the stance phase between shod and barefoot conditions. Compared with barefoot, wearing shoes showed significant changes ( p < 0.05): 1) the first MTPJ moved less inferior at 50% but moved less superior at 90 and 100% of the stance phase; 2) the peak medial, posterior, and superior translation of the first MTPJ significantly decreased in the shod condition; 3) the extension angle of the first MTPJ was larger at 30–60% but smaller at 90 and 100% of the stance phase; 4) the maximum extension angle and flexion/extension range of motion of the first MTPJ were reduced; and 5) the minimum extension and adduction angle of the first MTPJ was increased in the shod condition. On the basis of the high-speed DFIS, the aforementioned results indicated that wearing shoes limited the first MTPJ flexion and extension movement and increased the adduction angle, suggesting that shoes may affect the propulsion of the first MTPJ and increase the risk of hallux valgus.

          Related collections

          Most cited references35

          • Record: found
          • Abstract: found
          • Article: not found

          X-ray reconstruction of moving morphology (XROMM): precision, accuracy and applications in comparative biomechanics research.

          X-Ray Reconstruction of Moving Morphology (XROMM) comprises a set of 3D X-ray motion analysis techniques that merge motion data from in vivo X-ray videos with skeletal morphology data from bone scans into precise and accurate animations of 3D bones moving in 3D space. XROMM methods include: (1) manual alignment (registration) of bone models to video sequences, i.e., Scientific Rotoscoping; (2) computer vision-based autoregistration of bone models to biplanar X-ray videos; and (3) marker-based registration of bone models to biplanar X-ray videos. Here, we describe a novel set of X-ray hardware, software, and workflows for marker-based XROMM. Refurbished C-arm fluoroscopes retrofitted with high-speed video cameras offer a relatively inexpensive X-ray hardware solution for comparative biomechanics research. Precision for our biplanar C-arm hardware and analysis software, measured as the standard deviation of pairwise distances between 1 mm tantalum markers embedded in rigid objects, was found to be +/-0.046 mm under optimal conditions and +/-0.084 mm under actual in vivo recording conditions. Mean error in measurement of a known distance between two beads was within the 0.01 mm fabrication tolerance of the test object, and mean absolute error was 0.037 mm. Animating 3D bone models from sets of marker positions (XROMM animation) makes it possible to study skeletal kinematics in the context of detailed bone morphology. The biplanar fluoroscopy hardware and computational methods described here should make XROMM an accessible and useful addition to the available technologies for studying the form, function, and evolution of vertebrate animals.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Shoe midsole longitudinal bending stiffness and running economy, joint energy, and EMG.

            It has been shown that mechanical energy is dissipated at the metatarsophalangeal (MTP) joint during running and jumping. Furthermore, increasing the longitudinal bending stiffness of the midsole significantly reduced the energy dissipated at the MTP joint and increased jump performance. It was hypothesized that increasing midsole longitudinal bending stiffness would also lead to improvements in running economy. This study investigated the influence of midsole longitudinal bending stiffness on running economy (performance variable) and evaluated the local effects on joint energetics and muscular activity. Carbon fiber plates were inserted into running shoe midsoles and running economy, joint energy, and electromyographic (EMG) data were collected on 13 subjects. Approximately a 1% metabolic energy savings was observed when subjects ran in a stiff midsole relative to the control midsole. Subjects with a greater body mass had a greater decrease in oxygen consumption rates in the stiff midsole relative to the control midsole condition. The stiffer midsoles showed no significant differences in energy absorption at the MTP joint compared with the control shoe. Finally, no significant changes were observed in muscular activation. Increasing midsole longitudinal bending stiffness led to improvements in running economy, yet the underlying mechanisms that can be attributed to this improvement are still not fully understood.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Influence of midsole bending stiffness on joint energy and jump height performance.

              A substantial amount of rotational energy is lost at the metatarsophalangeal joint during running and jumping. We hypothesized that the lost energy could be decreased by increasing the bending stiffness of shoe midsoles. The purposes of this investigation were to determine the influence of stiff shoe midsoles on changes in lower extremity joint power during running and jumping and to determine the influence of stiff shoe midsoles on vertical jump performance. Carbon fiber plates were inserted into shoe midsoles and data were collected on five subjects during running and vertical jumping. The data showed that energy generation and absorption at each of the ankle, knee, and hip joints was not influenced by the stiffness of the shoe midsole. The stiff shoes with the carbon fiber plates did not increase the amount of energy stored and reused at the metatarsophalangeal joint; however, they reduced the amount of energy lost at this joint during both running and jumping. Vertical jump height was significantly higher (average, 1.7 cm for a group of 25 subjects) while wearing the stiff shoes. Increasing the bending stiffness of the metatarsophalangeal joint reduced the amount of energy lost at that joint and resulted in a corresponding improvement of performance.
                Bookmark

                Author and article information

                Contributors
                Journal
                Front Bioeng Biotechnol
                Front Bioeng Biotechnol
                Front. Bioeng. Biotechnol.
                Frontiers in Bioengineering and Biotechnology
                Frontiers Media S.A.
                2296-4185
                16 May 2022
                2022
                : 10
                : 892760
                Affiliations
                [1] 1 School of Kinesiology , Shanghai University of Sport , Shanghai, China
                [2] 2 School of Physical Education and Training , Shanghai University of Sport , Shanghai, China
                [3] 3 Key Laboratory of Exercise and Health Sciences of Ministry of Education , Shanghai University of Sport , Shanghai, China
                [4] 4 Shanghai Frontiers Science Research Base of Exercise and Metabolic Health, Shanghai University of Sport , Shanghai, China
                Author notes

                Edited by: Lizhen Wang, Beihang University, China

                Reviewed by: Tianyun Jiang, Beihang University, China

                Qichang Mei, Ningbo University, China

                *Correspondence: Weijie Fu, fuweijie@ 123456sus.edu.cn

                This article was submitted to Biomechanics, a section of the journal Frontiers in Bioengineering and Biotechnology

                Article
                892760
                10.3389/fbioe.2022.892760
                9148976
                35651545
                3a89084a-f012-4f62-a428-c76b90a08aba
                Copyright © 2022 Zhang, Ye, Zhang, Sun, Zhang, Wang and Fu.

                This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.

                History
                : 09 March 2022
                : 13 April 2022
                Funding
                Funded by: National Natural Science Foundation of China , doi 10.13039/501100001809;
                Award ID: 11772201
                Categories
                Bioengineering and Biotechnology
                Original Research

                dual fluoroscopic imaging system,barefoot,shod,first metatarsophalangeal joint, in vivo kinematics

                Comments

                Comment on this article