1
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: not found
      • Article: not found

      Addition by Subtraction in Mechanical Cardiac Support

      1 , 2
      JAMA
      American Medical Association (AMA)

      Read this article at

      ScienceOpenPublisher
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Related collections

          Most cited references11

          • Record: found
          • Abstract: found
          • Article: not found

          Long-term use of a left ventricular assist device for end-stage heart failure.

          Implantable left ventricular assist devices have benefited patients with end-stage heart failure as a bridge to cardiac transplantation, but their long-term use for the purpose of enhancing survival and the quality of life has not been evaluated. We randomly assigned 129 patients with end-stage heart failure who were ineligible for cardiac transplantation to receive a left ventricular assist device (68 patients) or optimal medical management (61). All patients had symptoms of New York Heart Association class IV heart failure. Kaplan-Meier survival analysis showed a reduction of 48 percent in the risk of death from any cause in the group that received left ventricular assist devices as compared with the medical-therapy group (relative risk, 0.52; 95 percent confidence interval, 0.34 to 0.78; P=0.001). The rates of survival at one year were 52 percent in the device group and 25 percent in the medical-therapy group (P=0.002), and the rates at two years were 23 percent and 8 percent (P=0.09), respectively. The frequency of serious adverse events in the device group was 2.35 (95 percent confidence interval, 1.86 to 2.95) times that in the medical-therapy group, with a predominance of infection, bleeding, and malfunction of the device. The quality of life was significantly improved at one year in the device group. The use of a left ventricular assist device in patients with advanced heart failure resulted in a clinically meaningful survival benefit and an improved quality of life. A left ventricular assist device is an acceptable alternative therapy in selected patients who are not candidates for cardiac transplantation.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Two-Year Outcomes with a Magnetically Levitated Cardiac Pump in Heart Failure

            In an early analysis of this trial, use of a magnetically levitated centrifugal continuous-flow circulatory pump was found to improve clinical outcomes, as compared with a mechanical-bearing axial continuous-flow pump, at 6 months in patients with advanced heart failure.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              A Fully Magnetically Levitated Circulatory Pump for Advanced Heart Failure.

              Background Continuous-flow left ventricular assist systems increase the rate of survival among patients with advanced heart failure but are associated with the development of pump thrombosis. We investigated the effects of a new magnetically levitated centrifugal continuous-flow pump that was engineered to avert thrombosis. Methods We randomly assigned patients with advanced heart failure to receive either the new centrifugal continuous-flow pump or a commercially available axial continuous-flow pump. Patients could be enrolled irrespective of the intended goal of pump support (bridge to transplantation or destination therapy). The primary end point was a composite of survival free of disabling stroke (with disabling stroke indicated by a modified Rankin score >3; scores range from 0 to 6, with higher scores indicating more severe disability) or survival free of reoperation to replace or remove the device at 6 months after implantation. The trial was powered for noninferiority testing of the primary end point (noninferiority margin, -10 percentage points). Results Of 294 patients, 152 were assigned to the centrifugal-flow pump group and 142 to the axial-flow pump group. In the intention-to-treat population, the primary end point occurred in 131 patients (86.2%) in the centrifugal-flow pump group and in 109 (76.8%) in the axial-flow pump group (absolute difference, 9.4 percentage points; 95% lower confidence boundary, -2.1 [P<0.001 for noninferiority]; hazard ratio, 0.55; 95% confidence interval [CI], 0.32 to 0.95 [two-tailed P=0.04 for superiority]). There were no significant between-group differences in the rates of death or disabling stroke, but reoperation for pump malfunction was less frequent in the centrifugal-flow pump group than in the axial-flow pump group (1 [0.7%] vs. 11 [7.7%]; hazard ratio, 0.08; 95% CI, 0.01 to 0.60; P=0.002). Suspected or confirmed pump thrombosis occurred in no patients in the centrifugal-flow pump group and in 14 patients (10.1%) in the axial-flow pump group. Conclusions Among patients with advanced heart failure, implantation of a fully magnetically levitated centrifugal-flow pump was associated with better outcomes at 6 months than was implantation of an axial-flow pump, primarily because of the lower rate of reoperation for pump malfunction. (Funded by St. Jude Medical; MOMENTUM 3 ClinicalTrials.gov number, NCT02224755 .).
                Bookmark

                Author and article information

                Journal
                JAMA
                JAMA
                American Medical Association (AMA)
                0098-7484
                November 11 2023
                Affiliations
                [1 ]Duke Clinical Research Institute, Durham, North Carolina
                [2 ]The Texas Heart Institute, Houston
                Article
                10.1001/jama.2023.22490
                4c18ec18-c1a9-4256-91f6-7d5a3ea15a7f
                © 2023
                History

                Comments

                Comment on this article