5
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: found
      Is Open Access

      Different classes of videoscopes and direct laryngoscopes for double-lumen tube intubation in thoracic surgery: A systematic review and network meta-analysis

      research-article
      , , , , *
      PLoS ONE
      Public Library of Science

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Background

          Double-lumen tube is commonly used in thoracic surgeries that need one-lung ventilation, but its big size and stiff structure make it harder to perform intubation than a conventional tracheal intubation tube.

          Objectives

          To investigate the effectiveness and safety of videoscopes for double-lumen tube insertion. The primary outcome was the success rate of first attempt intubation. Secondary outcomes were intubation time, malposition, oral mucosal damage, sore throat, and external manipulation.

          Design

          Systematic review and network meta-analysis

          Data sources

          Databases (Pubmed, Embase, Cochrane, Kmbase, Web of science, Scopus) up to June 23, 2020 were searched.

          Eligibility

          Randomized controlled trials comparing different videoscopes for double-lumen tube intubation were included in this study.

          Methods

          We classified and lumped the videoscope devices into the following groups: standard (non-channeled) videolaryngoscope, channeled videolaryngoscope, videostylet, and direct laryngoscope. After assessing the quality of evidence, we statistically analyzed and chose the best device based on the surface under the cumulative ranking curve (SUCRA) by using STATA software (version 16).

          Results

          We included 23 studies (2012 patients). Based on the success rate of the first attempt, a rankogram suggested that the standard videolaryngoscope (76.4 of SUCRA) was the best choice, followed by videostylet (65.5), channeled videolaryngoscope (36.1), and direct laryngoscope (22.1), respectively. However, with regard to reducing the intubation time, the best choice was videostylet, followed by a direct laryngoscope, channeled videolaryngoscope, and standard videolaryngoscope, respectively. Direct laryngoscope showed the lowest incidence of malposition but required external manipulation the most. Channeled videolaryngoscope showed the highest incidence of oral mucosal damage, but showed the lower incidence of sore throat than standard videolaryngoscope or direct laryngoscope.

          Conclusion

          Most videoscopes improved the success rate of double-lumen tube intubation; however, they were time-consuming (except videostylet) and had a higher malposition rate than the direct laryngoscope.

          Related collections

          Most cited references35

          • Record: found
          • Abstract: found
          • Article: not found

          A randomised controlled trial comparing the GlideScope(®) and the Macintosh laryngoscope for double-lumen endobronchial intubation.

          Double-lumen endobronchial tubes are the most common method of achieving lung isolation and one-lung ventilation during thoracic anaesthesia and surgery. We compared the clinical performance of the Macintosh laryngoscope and the GlideScope(®) during endobronchial intubation with a double-lumen tube. Seventy patients with no predictors for difficult laryngoscopy were allocated randomly to the Macintosh laryngoscope or GlideScope. The time taken for endobronchial intubation with the Macintosh laryngoscope was significantly shorter compared with that taken for the GlideScope, median (IQR [range]) 33 (22-52 [11-438]) s vs 70 (39-129 [21-242]) s, respectively, p = 0.0013. There was no statistical difference in the rate of success at the first attempt (91% vs 83%, respectively). On a numerical rating scale (scored from 0 to 10), the 30 anaesthetists who took part in the study rated endobronchial intubation overall as easier using the Macintosh compared with the GlideScope, 2 (1-3 [0-8]) vs 3 (2-6 [0-10]), respectively, p = 0.003. Postoperative voice changes were also less common in the Macintosh group (8 (22%) vs 17 (58%), p = 0.045). Anaesthetists found the GlideScope more difficult to use than the Macintosh laryngoscope and endobronchial intubation took longer; therefore, we cannot recommend its routine use with double-lumen tubes in patients who are predicted to have a normal airway. © 2013 The Association of Anaesthetists of Great Britain and Ireland.
            Bookmark
            • Record: found
            • Abstract: not found
            • Article: not found

            The PRISMA extension for network meta-analysis: bringing clarity and guidance to the reporting of systematic reviews incorporating network meta-analyses.

              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Comparison of the GlideScope® videolaryngoscope and the Macintosh laryngoscope for double-lumen tube intubation.

              Intubation with a double-lumen tube is important for achieving one-lung ventilation and facilitating thoracic surgery. The GlideScope(®) videolaryngoscope (Verathon Inc., Bothell, WA, USA) is designed to assist tracheal intubation for patients with a difficult airway. We wished to compare the GlideScope and direct laryngoscopy for double-lumen tube intubation. Sixty adult patients requiring a double-lumen tube for thoracic surgery and predicted uncomplicated laryngoscopy were randomly assigned to a direct Macintosh laryngoscopy group (n = 30) or a GlideScope group (n = 30). The mean (SD) duration of intubation was longer in the Macintosh group (62.5 (29.7) s) than in the GlideScope group (45.6 (10.7) s; p = 0.007). There was no difference in the success of the first attempt at intubation (26/30 (87%) and 30/30 (100%) for Macintosh and GlideScope groups, respectively; p = 0.112). The incidence of sore throat and hoarseness was higher in the Macintosh group (18 (60%) and 14 (47%), respectively) than in the GlideScope group (6 (20%) and 4 (13%), respectively; p = 0.003 and 0.004). We conclude that double-lumen tube intubation in patients with predicted normal laryngoscopy is easier using the GlideScope videolaryngoscope than the Macintosh laryngoscope. Anaesthesia © 2012 The Association of Anaesthetists of Great Britain and Ireland.
                Bookmark

                Author and article information

                Contributors
                Role: ConceptualizationRole: Data curationRole: Formal analysisRole: InvestigationRole: ValidationRole: VisualizationRole: Writing – original draft
                Role: Data curationRole: Formal analysisRole: ValidationRole: Writing – review & editing
                Role: Data curationRole: Formal analysisRole: InvestigationRole: MethodologyRole: ValidationRole: VisualizationRole: Writing – review & editing
                Role: ConceptualizationRole: Formal analysisRole: SupervisionRole: ValidationRole: Writing – review & editing
                Role: Data curationRole: Formal analysisRole: InvestigationRole: MethodologyRole: SupervisionRole: ValidationRole: VisualizationRole: Writing – review & editing
                Role: Editor
                Journal
                PLoS One
                PLoS ONE
                plos
                plosone
                PLoS ONE
                Public Library of Science (San Francisco, CA USA )
                1932-6203
                28 August 2020
                2020
                : 15
                : 8
                : e0238060
                Affiliations
                [001]Department of Anesthesiology and Pain Medicine, Korea University Guro Hospital, Seoul, Republic of Korea
                Zagazig University, EGYPT
                Author notes

                Competing Interests: The authors have declared that no competing interests exist.

                Author information
                http://orcid.org/0000-0001-8551-979X
                http://orcid.org/0000-0003-4046-0020
                Article
                PONE-D-20-01992
                10.1371/journal.pone.0238060
                7455027
                32857788
                4cfc9b68-0451-49a0-a804-d38b76ac9dec
                © 2020 Kim et al

                This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.

                History
                : 23 January 2020
                : 8 August 2020
                Page count
                Figures: 6, Tables: 1, Pages: 18
                Funding
                Funded by: Korea University (Departmental funding)
                Award Recipient :
                This report was supported by a Korea University Grant awarded to Dr. Young Ju Won from Korea University (Seoul, South Korea).
                Categories
                Research Article
                Medicine and Health Sciences
                Surgical and Invasive Medical Procedures
                Intubation
                Biology and Life Sciences
                Anatomy
                Neck
                Throat
                Larynx
                Medicine and Health Sciences
                Anatomy
                Neck
                Throat
                Larynx
                Biology and Life Sciences
                Anatomy
                Neck
                Throat
                Medicine and Health Sciences
                Anatomy
                Neck
                Throat
                Research and Analysis Methods
                Database and Informatics Methods
                Database Searching
                Medicine and Health Sciences
                Clinical Medicine
                Clinical Trials
                Randomized Controlled Trials
                Medicine and Health Sciences
                Pharmacology
                Drug Research and Development
                Clinical Trials
                Randomized Controlled Trials
                Research and Analysis Methods
                Clinical Trials
                Randomized Controlled Trials
                Research and Analysis Methods
                Mathematical and Statistical Techniques
                Statistical Methods
                Metaanalysis
                Physical Sciences
                Mathematics
                Statistics
                Statistical Methods
                Metaanalysis
                Computer and Information Sciences
                Network Analysis
                Medicine and Health Sciences
                Surgical and Invasive Medical Procedures
                Thoracic Surgery
                Custom metadata
                All relevant data are within the manuscript and its Supporting Information files.

                Uncategorized
                Uncategorized

                Comments

                Comment on this article