1
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: not found

      Alteration of load sharing of anterior cervical implants with change in cervical sagittal alignment.

      1 , , ,
      Medical engineering & physics
      Elsevier BV

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Anterior cervical discectomy and fusion (ACDF) is often supplemented with the application of an anterior plate to improve the stability of the fusion segment. While plate design has been shown to influence stress shielding of the graft, little is known about how the kyphotic alignment of a fused cervical segment affects the load sharing between the anterior plate and the osteoligamentous structures of the spine. The aim of this study was to characterize load sharing between an anterior plate and the osteoligamentous structures of the cervical motion segments in kyphotic versus normal lordotic alignment following single-level ACDF using fresh ovine cervical spines (C3-C6). The loading protocol involved preloading the spine with a 20 N compressive force and applying quasi-static moments (up to 2.1 Nm) in the sagittal plane to simulate flexion and extension. Stiffness of the fusion segment was measured from the moment-rotation plot. Normal lordotic alignment was replicated by insertion of a fibular allograft 2 mm taller than the interbody space. Kyphotic alignment was simulated by removing the graft and reapplying a shorter anterior cervical plate. The average segmental sagittal angulation at C4-C5 was 5.2+/-1.6 degrees of lordosis for the normal lordotic group and 6.8+/-2.3 degrees of kyphosis for the kyphotic group. With flexion, the plate shared 52.8% of the applied load in the normal lordotic group, and 70.1% in the kyphotic group (p<0.03). In extension, the amount of load-share by the plate in the normal lordotic group was comparable to that of the kyphotic group (52.7% vs. 40.7%, p=0.16). This study shows that kyphotic alignment of the cervical fusion segment increases the load sharing of the anterior plate under flexion loading.

          Related collections

          Author and article information

          Journal
          Med Eng Phys
          Medical engineering & physics
          Elsevier BV
          1350-4533
          1350-4533
          Jul 2008
          : 30
          : 6
          Affiliations
          [1 ] Department of Orthopaedic Surgery, Medical College of Wisconsin, Milwaukee, WI 53226, United States. meiwang@mcw.edu
          Article
          S1350-4533(07)00180-4
          10.1016/j.medengphy.2007.10.004
          18037331
          52f291fa-a1f4-435d-86ae-3c25c217e0bc
          History

          Comments

          Comment on this article