      Aptamer-based optical biosensor for rapid and sensitive detection of 17β-estradiol in water samples.

      Environmental Science & Technology
      Aptamers, Nucleotide, Biosensing Techniques, methods, Endocrine Disruptors, analysis, chemistry, Environmental Monitoring, Estradiol, Fluorescence, Optical Fibers, Serum Albumin, Bovine, Water Pollutants, Chemical

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Required routine monitoring of endocrine disrupting compounds (EDCs) in water samples, as posed by EPA Unregulated Contaminant Regulation (UCMR3), demands for cost-effective, reliable and sensitive EDC detection methods. This study reports a reusable evanescent wave aptamer-based biosensor for rapid, sensitive and highly selective detection of 17β-estradiol, an EDC that is frequently detected in environmental water samples. In this system, the capture molecular, β-estradiol 6-(O-carboxy-methyl)oxime-BSA, was covalently immobilized onto the optical fiber sensor surface. With an indirect competitive detection mode, samples containing different concentrations of 17β-estradiol were premixed with a given concentration of fluorescence-labeled DNA aptamer, which highly specifically binds to 17β-estradiol. Then, the sample mixture is pumped to the sensor surface, and a higher concentration of 17β-estradiol leads to less fluorescence-labeled DNA aptamer bound to the sensor surface and thus to lower fluorescence signal. The dose-response curve of 17β-estradiol was established and a detection limit was determined as 2.1 nM (0.6 ng mL(-1)). The high specificity and selectivity of the sensor were demonstrated by evaluating its response to a number of potentially interfering EDCs. Potential interference of real environmental sample matrix was assessed by spiked samples in several tertiary wastewater effluents. The sensor can be regenerated with a 0.5% SDS solution (pH 1.9) over tens of times without significant deterioration of the sensor performance. This portable sensor system can be potentially applied for on-site real-time inexpensive and easy-to-use monitoring of 17β-estradiol in environmental samples such as effluents or water bodies.

          Related collections

          Author and article information

          Comments

          Comment on this article