      Polar Vantage and Oura physical activity and sleep trackers: A validation and comparison study

      Preprint
      , , , ,
      medRxiv

      Read this article at

      ScienceOpenPublisher
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Background

          Consumer-based activity trackers are increasingly used in research as they have potential to increase activity participation and can be used for estimating physical activity. However, the accuracy of newer consumer-based devices is mostly unknown, and validation studies are needed.

          Objective

          The objective of this study was to test the accuracy of the Polar Vantage watch and Oura ring activity trackers for measuring physical activity, total energy expenditure, resting heart rate, and sleep duration, in free-living adults.

          Methods

          Twenty-one participants wore two consumer-based activity trackers (Polar, Oura), an ActiGraph accelerometer, an Actiheart accelerometer and heart rate monitor, and completed a sleep diary for up to seven days. We assessed Polar and Oura validity and comparability for physical activity, total energy expenditure, resting heart rate (Oura), and sleep duration. We analysed repeated measures correlation, Bland-Altman plots, and mean absolute percentage error.

          Results

          Polar and Oura were both strongly correlated (p<0.001) with ActiGraph for steps (Polar r 0.75, 95% CI 0.54-0.92. Oura r 0.77, 95% CI 0.62-0.87), moderate-to-vigorous physical activity (Polar r 0.76, 95% CI 0.62-0.88. Oura r 0.70, 95% CI 0.49-0.82), and total energy expenditure (Polar r 0.69, 95% CI 0.48-0.88. Oura r 0.70, 95% CI 0.51-0.83) and strongly or very strongly correlated (p<0.001) with the sleep diary for sleep duration (Polar r 0.74, 95% CI 0.56-0.88. Oura r 0.82, 95% CI 0.68-0.91). Oura had a very strong correlation (p<0.001) with Actiheart for resting heart rate ( r 0.9, 95% CI 0.85-0.96). However, all confidence interval ranges were wide and mean absolute percentage error was high for all variables, except Oura sleep duration (10%) and resting heart rate (3%) where Oura under-reported on average one beat per minute.

          Conclusions

          Oura can potentially be used as an alternative to Actiheart to measure resting heart rate. For sleep duration, Polar and Oura can potentially be used as a replacement for a manual sleep diary, depending on acceptable error. Neither Polar nor Oura can replace ActiGraph for measuring steps, moderate-to-vigorous physical activity, and total energy expenditure, but may be used as an additional source of physical activity in some settings.

          Related collections

          Author and article information

          Contributors
          (View ORCID Profile)
          (View ORCID Profile)
          (View ORCID Profile)
          (View ORCID Profile)
          (View ORCID Profile)
          Journal
          medRxiv
          April 11 2020
          Article
          10.1101/2020.04.07.20055756
          5691cf18-c4b9-4312-a27f-92f33fb7f8c8
          © 2020
          History

          Evolutionary Biology,Medicine
          Evolutionary Biology, Medicine

          Comments

          Comment on this article