          Abstract

          This study was performed to verify the influence of scanning-aid materials on the accuracy and time efficiency of full-arch scanning with intraoral scanners. The full-arch reference model was constructed by a 3D printer and scanned with a model scanner to obtain the reference dataset. Four experimental groups (application of ScanCure (SC-80, ODS Co, Incheon, Korea), IP Scan Spray (IP-Division, Haimhausen, Germany) and Vita Powder Scan Spray (Vita Zahnfabrik, Stuttgart, Germany), and no treatment) were designed, and the scans were executed (trueness, n = 5) using two intraoral scanners: I500 (Medit Co., Seoul, Korea) and TRIOS (3shape, Copenhagen, Denmark). All acquired scan data were compared with the reference datasets using the 3D superimposition method and 2D linear measurements. In the 3D analysis, intragroup data were compared with each other (precision, n = 10). Time efficiency was also verified by comparing the scan times of the four experimental groups. In the 3D analysis, the root mean square (RMS) value of the precision of the scanned image was statistically significantly more accurate in the scanning-aid agent-treated groups than in the no-treatment group (p < 0.05). However, the RMS values of trueness and the types of scanning-aid materials were not significantly different. In the 2D measurements, the increased scan distance generated a greater distance deviation. The working time was significantly shorter in the scanning-aid agent groups than in the no-treatment group, with statistical significance ( p < 0.05). Therefore, in clinical situations, the application of scanning-aid materials is recommended to reduce scanning time and more efficiently obtain the full-arch scanned image.

          Related collections

          Most cited references26

          • Record: found
          • Abstract: found
          • Article: found
          Is Open Access

          Comparison of digital and conventional impression techniques: evaluation of patients’ perception, treatment comfort, effectiveness and clinical outcomes

          Background The purpose of this study was to compare two impression techniques from the perspective of patient preferences and treatment comfort. Methods Twenty-four (12 male, 12 female) subjects who had no previous experience with either conventional or digital impression participated in this study. Conventional impressions of maxillary and mandibular dental arches were taken with a polyether impression material (Impregum, 3 M ESPE), and bite registrations were made with polysiloxane bite registration material (Futar D, Kettenbach). Two weeks later, digital impressions and bite scans were performed using an intra-oral scanner (CEREC Omnicam, Sirona). Immediately after the impressions were made, the subjects’ attitudes, preferences and perceptions towards impression techniques were evaluated using a standardized questionnaire. The perceived source of stress was evaluated using the State-Trait Anxiety Scale. Processing steps of the impression techniques (tray selection, working time etc.) were recorded in seconds. Statistical analyses were performed with the Wilcoxon Rank test, and p < 0.05 was considered significant. Results There were significant differences among the groups (p < 0.05) in terms of total working time and processing steps. Patients stated that digital impressions were more comfortable than conventional techniques. Conclusions Digital impressions resulted in a more time-efficient technique than conventional impressions. Patients preferred the digital impression technique rather than conventional techniques.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Accuracy of complete-arch dental impressions: a new method of measuring trueness and precision.

            A new approach to both 3-dimensional (3D) trueness and precision is necessary to assess the accuracy of intraoral digital impressions and compare them to conventionally acquired impressions.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Digital versus conventional impressions for fixed prosthodontics: A systematic review and meta-analysis.

              Limited evidence is available for the marginal and internal fit of fixed dental restorations fabricated with digital impressions compared with those fabricated with conventional impressions.
                Bookmark

                Author and article information

                Contributors
                Role: Academic Editor
                Journal
                Materials (Basel)
                Materials (Basel)
                materials
                Materials
                MDPI
                1996-1944
                30 April 2021
                May 2021
                : 14
                : 9
                : 2340
                Affiliations
                [1 ]Department of Prosthodontics and Dental Research Institute, School of Dentistry, Seoul National University, Seoul 03080, Korea; hsoh1391@ 123456snu.ac.kr (H.-S.O.); silk1@ 123456snu.ac.kr (M.-J.K.); proskwon@ 123456snu.ac.kr (H.-B.K.)
                [2 ]Dental Life Science Research Institute, Seoul National University Dental Hospital, Seoul 03080, Korea
                [3 ]Department of Prosthodontics, Seoul National University Gwanak Dental Hospital, School of Dentistry, Seoul National University, Seoul 03080, Korea; notus@ 123456hanmail.net
                Author notes
                [* ]Correspondence: limdds@ 123456snu.ac.kr (Y.-J.L.); bjkim016@ 123456gmail.com (B.K.); Tel.: +82-2-2072-2940 (Y.-J.L.); +82-2-2072-4455 (B.K.)
                Author information
                https://orcid.org/0000-0003-2504-9671
                https://orcid.org/0000-0001-7309-5977
                https://orcid.org/0000-0003-2020-5284
                Article
                materials-14-02340
                10.3390/ma14092340
                8124155
                33946471
                58b26dd8-f9d8-4754-9294-77be7a82aebc
                © 2021 by the authors.

                Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license ( https://creativecommons.org/licenses/by/4.0/).

                History
                : 24 March 2021
                : 27 April 2021
                Categories
                Article

                intraoral scanners,full arch,trueness,precision,time efficiency,scanning-aid materials

                Comments

                Comment on this article