      Real-Time Monitoring of Fibrinogen Cross-Linking on Model Biomaterial Surfaces with Quartz Crystal Microbalance

      ,
      The Open Biotechnology Journal
      Bentham Science Publishers Ltd.

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          A quartz crystal microbalance was used for real-time monitoring of fibrinogen cross-linking on three model biomaterial surfaces. Fibrinogen adsorbs slowly and forms a less rigid multi-layer on hydrophobic surfaces, while it adsorbs quickly, forming a single mono-layer on hydrophilic surfaces. The extent of fibrinogen cross-linking is greater on hydrophobic surfaces. Fibrinogen cross-linking can also rigidify the relatively soft coatings of poly(methyl methacrylate) and dodecanethiol self-assembled monolayer.