      Centrifugation may eliminate false-positive leucocyte esterase strip test results caused by inflammatory arthritis in the diagnosis of knee infection : A pilot study

      research-article

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Aims

          The purpose of this study was to validate our hypothesis that centrifugation may eliminate false-positive leucocyte esterase (LE) strip test results caused by autoimmune diseases in the diagnosis of knee infection.

          Methods

          Between January 2016 and May 2019, 83 cases, including 33 cases of septic arthritis and 50 cases of aseptic arthritis, were enrolled in this study. To further validate our hypothesis, another 34 cases of inflammatory arthritis from the Department of Rheumatology of our institution were also included. After aspiration, one drop of synovial fluid was applied to LE strips before and after centrifugation. The results were recorded after approximately three minutes according to the different colour grades on the colour chart. The differences of LE results between each cohort were analyzed.

          Results

          Before centrifugation, 46% (23/50) of the LE strip tests in the aseptic arthritis group were false-positives. Most of the false-positive results were due to inflammatory arthritis; after centrifugation, 78.3% (18/23) of the tests yielded negative results. Similar results were observed in cases from the Department of Rheumatology. The sensitivity of the centrifuged LE strip test was 0.818 (0.639 to 0.924), which is still an acceptable level compared with the uncentrifuged results, which yielded a sensitivity of 0.909 (0.745 to 0.976). However, the specificity was increased from 0.540 (0.395 to 0.679) to 0.900 (0.774 to 0.963) after centrifugation.

          Conclusion

          Although inflammatory arthritis can yield a false-positive LE strip test result in the diagnosis of knee infection, centrifugation may eliminate these false-positive results.

          Cite this article: Bone Joint Res. 2020;9(5):236–241.

          Related collections

          Most cited references13

          • Record: found
          • Abstract: found
          • Article: not found

          Clinical features and outcome of septic arthritis in a single UK Health District 1982-1991.

          To determine the clinical features of a large number of unselected UK hospital patients with confirmed septic arthritis and to determine those features associated with a poor outcome. Retrospective, case-note survey. A single English Health District. All patients admitted to hospital in Nottingham during the period 1 January 1982 to 31 December 1991 with confirmed septic arthritis were included. Death, osteomyelitis and recorded functional impairment. The spectrum of causative organisms remains similar to that seen in previous studies with the Gram positive organisms Staphylococcus aureus and Streptococci responsible for 74% of cases, gonococcal infections though were less common. Culture of joint aspirates and or blood were positive in 82% of cases, with the Gram stain demonstrating the causative organism in 50% of cases. Pre-existing joint disease was evident in 35% of cases. The mortality remains high at 11.5% with a significant additional morbidity of 31.6%. Multivariate analysis suggests that important predictors of death are: confusion at presentation, age > or = 65 years, multiple joint sepsis or involvement of the elbow joint, and of morbidity are: age > or = 65 years, diabetes mellitus, open surgical drainage, and Gram positive infections other than S aureus. Septic arthritis continues to be associated with a considerable degree of morbidity and mortality. These results confirm the importance of obtaining synovial fluid and blood for culture before starting antimicrobial treatment. The apparent poorer outcome found with surgical intervention is in line with some previous suggestions but should be interpreted with caution in light of the retrospective nature of this study.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Synovial Fluid Biomarkers for the Diagnosis of Periprosthetic Joint Infection: A Systematic Review and Meta-Analysis.

            The search for a single standard reference test for determining periprosthetic joint infection (PJI) through analysis of synovial fluid has yielded numerous biomarkers as potential candidates. The purpose of the present systematic review and meta-analysis was to evaluate the diagnostic accuracy of synovial fluid biomarkers and to determine which test has the highest diagnostic odds ratio (DOR) for the diagnosis of PJI.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Diagnosis of periprosthetic joint infection: the utility of a simple yet unappreciated enzyme.

              The white blood-cell count and neutrophil differential of the synovial fluid have been reported to have high sensitivity and specificity in the diagnosis of periprosthetic infection following total knee arthroplasty. We hypothesized that neutrophils recruited into an infected joint secrete enzymes that may be used as markers for infection. In this prospective study, we determined the sensitivity and specificity of one of these enzymes, leukocyte esterase, in diagnosing periprosthetic joint infection. Between May 2007 and April 2010, synovial fluid was obtained preoperatively from the knees of patients with a possible joint infection and intraoperatively from the knees of patients undergoing revision knee arthroplasty. The aspirate was tested for the presence of leukocyte esterase with use of a simple colorimetric strip test. The color change (graded as negative, trace, +, or ++), which corresponded to the level of the enzyme, was noted after one or two minutes. On the basis of clinical, serological, and operative criteria, thirty of the 108 knees undergoing revision arthroplasty were infected and seventy-eight were uninfected. When only a ++ reading was considered positive, the leukocyte esterase test was 80.6% sensitive (95% confidence interval [CI], 61.9% to 91.9%) and 100% specific (95% CI, 94.5% to 100.0%), with a positive predictive value of 100% (95% CI, 83.4% to 100.0%) and a negative predictive value of 93.3% (95% CI, 85.4% to 97.2%). The leukocyte esterase level correlated strongly with the percentage of polymorphonuclear leukocytes (r = 0.7769) and total white blood-cell count (r = 0.5024) in the aspirate as well as with the erythrocyte sedimentation rate (r = 0.6188) and C-reactive protein level (r = 0.4719) in the serum. The simple colorimetric strip test that detects the presence of leukocyte esterase in synovial fluid appears to be an extremely valuable addition to the physician's armamentarium for the diagnosis of periprosthetic joint infection. The leukocyte esterase reagent strip has the advantages of providing real-time results, being simple and inexpensive, and having the ability to both rule out and confirm periprosthetic joint infection. However, additional multicenter studies are required to substantiate the results of our preliminary investigation before the reagent strip can be used confidently in the clinic or intraoperative setting.
                Bookmark

                Author and article information

                Contributors
                Role: Attending Physician
                Role: Postdoctoral Researcher
                Role: Attending Physician
                Role: Resident
                Role: Associate Chief Physician
                Role: Associate Chief Physician
                Role: Associate Chief Physician
                Role: Chief Physician and Deputy Director of Department of Orthopedics
                Journal
                Bone Joint Res
                Bone & Joint Research
                2046-3758
                May 2020
                8 June 2020
                : 9
                : 5
                : 236-241
                Affiliations
                [1 ]Department of Orthopedics, Chinese PLA General Hospital, Beijing, China
                [2 ]Medical Laboratory Center, Chinese PLA General Hospital, Beijing, China
                [3 ]Department of Rheumatology, Chinese PLA General Hospital, Beijing, China
                [4 ]Department of Orthopedics, Chinese PLA General Hospital, Beijing, China
                Author notes
                Article
                10.1302_2046-3758.95.BJR-2019-0245.R1
                10.1302/2046-3758.95.BJR-2019-0245.R1
                7284292
                6116d128-2323-4975-9d04-ffcafa209b2a
                © 2020 Author(s) et al

                Open Access This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial No Derivatives (CC BY-NC-ND 4.0) licence, which permits the copying and redistribution of the work only, and provided the original author and source are credted. See https://creativecommons.org/licenses/by-nc-nd/4.0/.

                History
                Categories
                Infection
                9
                Leucocyte Esterase
                Infection
                Inflammatory Arthritis

                leucocyte esterase,infection,inflammatory arthritis
                leucocyte esterase, infection, inflammatory arthritis

                Comments

                Comment on this article