      Newborn screening for isovaleric acidemia using tandem mass spectrometry: data from 1.6 million newborns.

      Clinical chemistry
      Humans, Infant, Newborn, Neonatal Screening, Pentanoic Acids, blood, Spectrometry, Mass, Electrospray Ionization, methods, Tandem Mass Spectrometry

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Electrospray ionization-tandem mass spectrometry (ESI-MS/MS) has been used in the Bavarian newborn screening (NBS) program since 1999. The use of ESI-MS/MS has led to the inclusion of isovaleric acidemia (IVA) into NBS. We retrospectively evaluated data on more than 1.6 million newborns screened during 9.5 years. Acylcarnitines from whole blood spotted on filter paper were converted to their corresponding butyl esters, and the samples were analyzed by use of ESI-MS/MS with stable isotope labeled internal standards. A total of 24 individuals with IVA were detected by use of a multiparametric threshold criteria panel including isovalerylcarnitine (C5) and the ratios of C5 to octanoyl-, butyryl-, and propionylcarnitine. A cutoff set at the 99.99th percentile for isolated C5 or at the 99th percentile for C5 plus at least 2 ratios resulted in a positive predictive value for IVA screening of 7.0% and an overall recall rate of 0.024%. Adjusted reference ranges for age and birth weight were applied, and the incidence of IVA in the study population was calculated to be 1 in 67,000. Missed cases were not brought to our attention. IVA was also detectable in cord blood and early postnatal blood samples. IVA can be reliably detected in NBS through acylcarnitine analysis in dried blood spots by using multiparametric threshold criteria. Further improvement (positive predictive value 13.0%, recall rate 0.01%) can be achieved by using more stringent recall criteria. In view of the potentially life-threatening natural course of IVA in early life, presymptomatic diagnosis may thus prevent mortality and morbidity.

          Related collections

          Author and article information

          Journal
          21335445
          10.1373/clinchem.2010.151134

          Chemistry
          Humans,Infant, Newborn,Neonatal Screening,Pentanoic Acids,blood,Spectrometry, Mass, Electrospray Ionization,methods,Tandem Mass Spectrometry

          Comments

          Comment on this article