0
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: not found

      WEARABLE SWEAT SENSING DEVICE FOR DETECTION OF IBD BIOMARKERS

      , ,
      Inflammatory Bowel Diseases
      Oxford University Press (OUP)

      Read this article at

      ScienceOpenPublisher
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Introduction

          Inflammatory Bowel Disease affects 1.2 million in the United States. Flare-up of the disease occurs in a random way and current testing methods lack ability for real-time prediction of a flare up. The levels of cytokines elevate during a flareup. Therefore, we hypothesize that real-time monitoring of cytokine biomarkers can be useful for early detection of flare-ups and provide better patient management. In this context, sweat-based diagnostics can be promising for real-time tracking of IBD biomarkers.

          Materials and Methods

          A wearable SWEATSENSER was developed by functionalization of specific affinity capture probes (IL-1β, CRP antibodies) on metal/semiconducting interface deposited on a porous patch substrate. Electrochemical impedance spectroscopy technique was used to detect the interaction between the specific antibody and target analyte. The developed SWEATSENSER was tested on 20 healthy human subjects in compliance with an approved IRB at UT Dallas. Continuous on-body measurements were recorded to report IL-1β, CRP levels in sweat in real-time.

          Results

          In this work, a wearable multiplexed sweat sensor for detection of IL-1β, CRP in sweat has been demonstrated. The sensor demonstrates a limit of detection of 1 pg/mL with a dynamic range from 1 pg/mL- 512 pg/mL for both the biomarkers in sweat. The sweat sensor demonstrated excellent correlation with reference ELISA method (Pearson’s r ≥0.95). On-body monitoring using sweat sensor from passively perspired human sweat demonstrated a mean concentration of 28 pg/mL for IL-1β in healthy cohort.

          Conclusion

          A wearable sweat sensor was developed to monitor potential IBD markers in sweat. The developed device can be useful in better management of IBD patients.

          Related collections

          Author and article information

          Journal
          Inflammatory Bowel Diseases
          Oxford University Press (OUP)
          1078-0998
          1536-4844
          January 01 2021
          January 21 2021
          January 21 2021
          January 01 2021
          January 21 2021
          January 21 2021
          : 27
          : Supplement_1
          : S12
          Article
          10.1093/ibd/izaa347.028
          64e51a25-197a-4a3d-8837-3e351e18aa97
          © 2021

          https://academic.oup.com/journals/pages/open_access/funder_policies/chorus/standard_publication_model

          History

          Comments

          Comment on this article