      Periprosthetic joint infection: Comparison of automated multiplex-PCR Unyvero i60 ITI cartridge system with bacterial culture and real-time PCR

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          BACKGROUND: In the past, various efforts have been made to investigate diagnostic tools for periprosthetic-joint-infection (PJI). It is little-known about the diagnostic utility of polymerase-chain-reaction (PCR) in this context, especially concerning the role of multiplex-PCR assays comparing with conventional tissue culture. OBJECTIVE: Evaluation of an automated-multiplex-PCR cartridge system for patients with suspicion of PJI in comparison with conventional microbiological culture and 16S-rDNA-PCR. METHODS: On suspicion of PJI synovial fluid specimen were taken preoperatively or periprosthetic tissue was collected intraoperatively. Microbiological analysis included conventional culture, 16S-rDNA-PCR and automated-multiplex-PCR (Unyvero-i60-ITI®). The European-Bone-and-Joint-Infection-Society (EBJIS) criteria were used for PJI diagnosis. Positive and negative percent agreement was calculated. Total percentage agreement and Cohen’s kappa coefficient were calculated. Sensitivity, specificity and positive predictive value of conventional culture, 16S-rDNA-PCR and multiplex-PCR were calculated. Ten specimens of proved PJI were used as control group. RESULTS: Fifty specimen were suitable for culture. 14 (28%) were classified as PJI, 36 (72%) were aseptic. Coagulase-negative staphylococci was the most frequent detected pathogen. Concordance-rate between mPCR and culture results was 75.6% with a Cohen’s kappa of 0.28. Concordance-rate between mPCR and 16S-rDNA was 82.9%, Cohen’s kappa was 0.13. Concordance analysis between culture results and 16S-rDNA lead to a concordance-rate of 88.9%. Cohen’s kappa was calculated with 0.6. With regard to the microbiological culture as reference, sensitivity of the mPCR was 0.33 and specificity was 0.91. Sensitivity and specificity of the 16S-rDNA-PCR was 0.55 and 0.97. The positive predictive value was 0.57 for the mPCR and 0.83 for the 16S-rDNA-PCR. CONCLUSIONS: Due to fair agreement between mPCR and conventional microbiological culture, the tested multiplex-PCR could be an additional instrument for the detection of PJI but is not superior over the conventional culture.

          Related collections

          Most cited references33

          • Record: found
          • Abstract: found
          • Article: not found

          Greengenes, a Chimera-Checked 16S rRNA Gene Database and Workbench Compatible with ARB

          A 16S rRNA gene database ( http://greengenes.lbl.gov ) addresses limitations of public repositories by providing chimera screening, standard alignment, and taxonomic classification using multiple published taxonomies. It was found that there is incongruent taxonomic nomenclature among curators even at the phylum level. Putative chimeras were identified in 3% of environmental sequences and in 0.2% of records derived from isolates. Environmental sequences were classified into 100 phylum-level lineages in the Archaea and Bacteria .
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Diagnosis and management of prosthetic joint infection: clinical practice guidelines by the Infectious Diseases Society of America.

            These guidelines are intended for use by infectious disease specialists, orthopedists, and other healthcare professionals who care for patients with prosthetic joint infection (PJI). They include evidence-based and opinion-based recommendations for the diagnosis and management of patients with PJI treated with debridement and retention of the prosthesis, resection arthroplasty with or without subsequent staged reimplantation, 1-stage reimplantation, and amputation.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: found
              Is Open Access

              The ribosomal database project (RDP-II): introducing myRDP space and quality controlled public data

              Substantial new features have been implemented at the Ribosomal Database Project in response to the increased importance of high-throughput rRNA sequence analysis in microbial ecology and related disciplines. The most important changes include quality analysis, including chimera detection, for all available rRNA sequences and the introduction of myRDP Space, a new web component designed to help researchers place their own data in context with the RDP's data. In addition, new video tutorials describe how to use RDP features. Details about RDP data and analytical functions can be found at the RDP-II website ().
                Bookmark

                Author and article information

                Journal
                Technology and Health Care
                THC
                IOS Press
                09287329
                18787401
                July 08 2022
                July 08 2022
                : 30
                : 4
                : 1005-1015
                Affiliations
                [1 ]Department of Orthopaedic Surgery, University of Wuerzburg, Wuerzburg, Germany
                [2 ]Institute for Hygiene and Microbiology, University of Wuerzburg, Wuerzburg, Germany
                Article
                10.3233/THC-213248
                35068428
                6b65b313-b8ad-495a-a5a7-9494ada74ed4
                © 2022
                History

                Comments

                Comment on this article