7
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: not found

      An alternative to tandem mass spectrometry: isoelectric point and accurate mass for the identification of peptides.

      Analytical Chemistry
      Algorithms, Amino Acid Sequence, Animals, Computational Biology, methods, Computer Simulation, Databases, Protein, Escherichia coli Proteins, analysis, Isoelectric Focusing, Isoelectric Point, Mass Spectrometry, statistics & numerical data, Models, Theoretical, Molecular Sequence Data, Molecular Weight, Peptide Fragments, Peptides, Proteins, Proteome, Rats, Reproducibility of Results

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          The traditional approach to the identification of peptides in complex biological samples integrally involves the use of tandem mass spectrometry to generate a unique fragmentation pattern in order to accurately assign its identity to a particular protein. In this article we describe the theoretical basis for a new paradigm for the identification of peptides and proteins. This methodology employs the use of accurate mass and peptide isoelectric point (pI) as identification criteria, and represents a change in focus from current tandem mass spectrometry-dominated approaches. A mathematical derivation of the false positive rate associated with accurate mass and pI measurements is presented to demonstrate the utility of the technique. The equations for calculation of the experimental false positive rate allow for the determination of the validity of the data. The false positive rate issue examined in detail here is not restricted to accurate mass-based approaches, but also has application to the tandem mass spectrometry community as well. The theoretical proteomes of Escherichia coli and Rattus norvegicus are used to evaluate the efficacy of this approach. The power of the technique is demonstrated by analyzing a series of peptides with the same monoisotopic masses but with differing isoelectric points. Finally, the speed of algorithm when combined with the experimental peptide analysis has the potential to rapidly accelerate the protein identification process.

          Related collections

          Author and article information

          Comments

          Comment on this article