12
views
0
recommends
+1 Recommend
1 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: found
      Is Open Access

      Cytotoxicity and biocompatibility of a new bioceramic endodontic sealer containing calcium hydroxide

      research-article

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Abstract: This study evaluated the cytotoxicity and biocompatibility of a new bioceramic endodontic sealer (i.e., Sealer Plus BC) in comparison with those of MTA Fillapex and AH Plus. L929 fibroblasts were cultured and Alamar Blue was used to evaluate cell viability of diluted extracts (1:50, 1:100, and 1:200) from each sealer at 24 h. Polyethylene tubes that were filled with material or empty (as a control) were implanted in the subcutaneous tissue of rats. The rats were killed after 7 and 30 d (n = 8), and the tubes were removed for histological analysis. Parametric data was analyzed using a one-way ANOVA test, and nonparametric data was analyzed via the Kruskal–Wallis test followed by the Dunn test (p < 0.05). A reduction in cell viability was observed in the extracts that were more diluted for Sealer Plus BC when compared to that of Control and AH Plus (p < 0.05). However, the 1:50 dilution of the Sealer Plus BC was similar to that of the Control (p > 0.05). Conversely, more diluted extracts of MTA Fillapex (1:200) and AH Plus (1:100 and 1:200) were similar to the Control (p > 0.05). Histological analysis performed at 7 d did not indicate any significant difference between tissue response for all materials, and the fibrous capsule was thick (p > 0.05). At 30 d, Sealer Plus BC was similar to the Control (p > 0.05) and MTA Fillapex and AH Plus exhibited greater inflammation than the Control (p < 0.05). The fibrous capsule was thin for the Control and for most specimens of Sealer Plus BC and AH Plus. Thus, Sealer Plus BC is biocompatible when compared to MTA Fillapex and AH Plus, and it is less cytotoxic when less-diluted extracts are used.

          Related collections

          Most cited references37

          • Record: found
          • Abstract: found
          • Article: not found

          Mineral trioxide aggregate: a comprehensive literature review--Part III: Clinical applications, drawbacks, and mechanism of action.

          Mineral trioxide aggregate (MTA) has been recommended for various uses in endodontics. Two previous publications provided a comprehensive list of articles from November 1993-September 2009 regarding the chemical and physical properties, sealing ability, antibacterial activity, leakage, and biocompatibility of MTA. The purpose of Part III of this literature review is to present a comprehensive list of articles regarding animal studies, clinical applications, drawbacks, and mechanism of action of MTA. A review of the literature was performed by using electronic and hand-searching methods for the clinical applications of MTA in experimental animals and humans as well as its drawbacks and mechanism of action from November 1993-September 2009. MTA is a promising material for root-end filling, perforation repair, vital pulp therapy, and apical barrier formation for teeth with necrotic pulps and open apexes. Despite the presence of numerous case reports and case series regarding these applications, there are few designed research studies regarding clinical applications of this material. MTA has some known drawbacks such as a long setting time, high cost, and potential of discoloration. Hydroxyapatite crystals form over MTA when it comes in contact with tissue synthetic fluid. This can act as a nidus for the formation of calcified structures after the use of this material in endodontic treatments. On the basis of available information, it appears that MTA is the material of choice for some clinical applications. More clinical studies are needed to confirm its efficacy compared with other materials. Copyright (c) 2010. Published by Elsevier Inc.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Physical properties of 5 root canal sealers.

            The aim of this study was to evaluate the pH change, viscosity and other physical properties of 2 novel root canal sealers (MTA Fillapex and Endosequence BC) in comparison with 2 epoxy resin-based sealers (AH Plus and ThermaSeal), a silicone-based sealer (GuttaFlow), and a zinc oxide-eugenol-based sealer (Pulp Canal Sealer).
              Bookmark
              • Record: found
              • Abstract: not found
              • Article: not found

              Bioceramics: Past, present and for the future

                Bookmark

                Author and article information

                Contributors
                Role: ND
                Role: ND
                Role: ND
                Role: ND
                Role: ND
                Role: ND
                Role: ND
                Journal
                bor
                Brazilian Oral Research
                Braz. oral res.
                Sociedade Brasileira de Pesquisa Odontológica - SBPqO (São Paulo, SP, Brazil )
                1806-8324
                1807-3107
                May 2019
                : 33
                : 0
                : e042
                Affiliations
                [3] Araçatuba orgnameUniversidade Estadual Paulista orgdiv1School of Dentistry orgdiv2Department of Basic Sciences Brazil
                [1] Araçatuba orgnameUniversidade Estadual Paulista orgdiv1School of Dentistry orgdiv2Departament of Endodontics Brazil
                [2] Ann Arbor Michigan orgnameUniversity of Michigan orgdiv1Department of Cariology, Restorative Sciences and Endodontics United States
                Article
                S1806-83242019000100232
                10.1590/1807-3107bor-2019.vol33.0042
                31508725
                760bb0af-0f87-4124-a8b2-40cab53265f9

                This work is licensed under a Creative Commons Attribution 4.0 International License.

                History
                : 06 August 2018
                : 11 April 2019
                Page count
                Figures: 0, Tables: 0, Equations: 0, References: 39, Pages: 0
                Product

                SciELO Brazil

                Categories
                Original Research

                Cell Culture Techniques,Endodontics,Inflammation,Materials Testing

                Comments

                Comment on this article