      The volume of peripapillary vessels within the retinal nerve fibre layer: an optical coherence tomography angiography study of normal subjects

      , , , , , ,
      British Journal of Ophthalmology
      BMJ

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          To investigate the contribution of vascular volume calculated by optical coherence tomography angiography (OCTA) to the measurement of peripapillary retinal nerve fibre layer (RNFL) thickness.

          Related collections

          Most cited references15

          • Record: found
          • Abstract: found
          • Article: not found

          Optical coherence tomography angiography of optic disc perfusion in glaucoma.

          To compare optic disc perfusion between normal subjects and subjects with glaucoma using optical coherence tomography (OCT) angiography and to detect optic disc perfusion changes in glaucoma.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: found
            Is Open Access

            Optical Coherence Tomography Angiography Vessel Density in Healthy, Glaucoma Suspect, and Glaucoma Eyes

            Purpose The purpose of this study was to compare retinal nerve fiber layer (RNFL) thickness and optical coherence tomography angiography (OCT-A) retinal vasculature measurements in healthy, glaucoma suspect, and glaucoma patients. Methods Two hundred sixty-one eyes of 164 healthy, glaucoma suspect, and open-angle glaucoma (OAG) participants from the Diagnostic Innovations in Glaucoma Study with good quality OCT-A images were included. Retinal vasculature information was summarized as a vessel density map and as vessel density (%), which is the proportion of flowing vessel area over the total area evaluated. Two vessel density measurements extracted from the RNFL were analyzed: (1) circumpapillary vessel density (cpVD) measured in a 750-μm-wide elliptical annulus around the disc and (2) whole image vessel density (wiVD) measured over the entire image. Areas under the receiver operating characteristic curves (AUROC) were used to evaluate diagnostic accuracy. Results Age-adjusted mean vessel density was significantly lower in OAG eyes compared with glaucoma suspects and healthy eyes. (cpVD: 55.1 ± 7%, 60.3 ± 5%, and 64.2 ± 3%, respectively; P < 0.001; and wiVD: 46.2 ± 6%, 51.3 ± 5%, and 56.6 ± 3%, respectively; P < 0.001). For differentiating between glaucoma and healthy eyes, the age-adjusted AUROC was highest for wiVD (0.94), followed by RNFL thickness (0.92) and cpVD (0.83). The AUROCs for differentiating between healthy and glaucoma suspect eyes were highest for wiVD (0.70), followed by cpVD (0.65) and RNFL thickness (0.65). Conclusions Optical coherence tomography angiography vessel density had similar diagnostic accuracy to RNFL thickness measurements for differentiating between healthy and glaucoma eyes. These results suggest that OCT-A measurements reflect damage to tissues relevant to the pathophysiology of OAG.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Projection-resolved optical coherence tomographic angiography.

              Shadowgraphic projection artifacts from superficial vasculature interfere with the visualization of deeper vascular networks in optical coherence tomography angiography (OCT-A). We developed a novel algorithm to remove this artifact by resolving the ambiguity between in situ and projected flow signals. The algorithm identifies voxels with in situ flow as those where intensity-normalized decorrelation values are higher than all shallower voxels in the same axial scan line. This "projection-resolved" (PR) algorithm effectively suppressed the projection artifact on both en face and cross-sectional angiograms and enhanced depth resolution of vascular networks. In the human macula, the enhanced angiograms show three distinct vascular plexuses in the inner retina and no vessels in the outer retina. We demonstrate that PR OCT-A cleanly removes flow projection from the normally avascular outer retinal slab while preserving the density and continuity of the intermediate and deep retinal capillary plexuses.
                Bookmark

                Author and article information

                Journal
                British Journal of Ophthalmology
                Br J Ophthalmol
                BMJ
                0007-1161
                1468-2079
                April 19 2018
                May 2018
                May 2018
                August 16 2017
                : 102
                : 5
                : 611-621
                Article
                10.1136/bjophthalmol-2017-310214
                28814416
                7c9e252e-5aed-4543-82f8-cf028dc50a0b
                © 2017
                History

                Comments

                Comment on this article