24
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: found
      Is Open Access

      Torsional and flattening effect on corneal astigmatism after cataract surgery: a retrospective analysis

      research-article

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Background

          To evaluate the torsional and flattening effect of steep meridian incisions and influence of posterior corneal astigmatism (PCA) on total corneal astigmatism (TCA) after cataract surgery.

          Methods

          One hundred thirty-two eyes underwent cataract surgery with steep meridian 2.2 mm microcoaxial and 2.85 mm conventional clear corneal incisions. Eyes were divided into with-the-rule (WTR) astigmatism and against-the-rule (ATR) astigmatism groups depending on the steeper meridian and measured with autokeratorefractor and Pentacam® before surgery, at 1 day, 1 week, 1 and 2 months postoperatively. Polar vector analysis was used to evaluate torsional effect of steep meridian incisions.

          Results

          A decrease in astigmatic polar value (AKP) (+0) was observed in both keratometric and total astigmatism (TA) after 1 and 2 months, although the decrease was only statistically significant in TA ( p < 0.05). The AKP(+45) was more significant in the conventional group than the microcoaxial group at 2 months postoperatively ( p < 0.05, respectively). There was a significant correlation between corneal thickness of the superior quadrant and PCA in the WTR group ( p = 0.028). In eyes with anterior corneal astigmatism smaller than 0.55D of WTR astigmatism and PCA greater than 0.35D of WTR astigmatism showed greater shifting of steep axis and also increment of refractive cylinder powers.

          Conclusions

          In eyes with superior corneal thickness greater than 714.5 μm and PCA greater than 0.35D of WTR astigmatism, steep meridian incision may cause a significant torsional effect and off-steep meridian change, contributing to an increment of postoperative residual manifest astigmatism after cataract surgery.

          Related collections

          Most cited references23

          • Record: found
          • Abstract: found
          • Article: not found

          Contribution of posterior corneal astigmatism to total corneal astigmatism.

          To determine the contribution of posterior corneal astigmatism to total corneal astigmatism and the error in estimating total corneal astigmatism from anterior corneal measurements only using a dual-Scheimpflug analyzer. Cullen Eye Institute, Baylor College of Medicine, Houston, Texas, USA. Case series. Total corneal astigmatism was calculated using ray tracing, corneal astigmatism from simulated keratometry, anterior corneal astigmatism, and posterior corneal astigmatism, and the changes with age were analyzed. Vector analysis was used to assess the error produced by estimating total corneal astigmatism from anterior corneal measurements only. The study analyzed 715 corneas of 435 consecutive patients. The mean magnitude of posterior corneal astigmatism was -0.30 diopter (D). The steep corneal meridian was aligned vertically (60 to 120 degrees) in 51.9% of eyes for the anterior surface and in 86.6% for the posterior surface. With increasing age, the steep anterior corneal meridian tended to change from vertical to horizontal, while the steep posterior corneal meridian did not change. The magnitudes of anterior and posterior corneal astigmatism were correlated when the steeper anterior meridian was aligned vertically but not when it was aligned horizontally. Anterior corneal measurements underestimated total corneal astigmatism by 0.22 @ 180 and exceeded 0.50 D in 5% of eyes. Ignoring posterior corneal astigmatism may yield incorrect estimation of total corneal astigmatism. Selecting toric intraocular lenses based on anterior corneal measurements could lead to overcorrection in eyes that have with-the-rule astigmatism and undercorrection in eyes that have against-the-rule astigmatism. The authors received research support from Ziemer Group. In addition, Dr. Koch has a financial interest with Alcon Laboratories, Inc., Abbott Medical Optics, Inc., Calhoun Vision, Inc., NuLens, and Optimedica Corp. Copyright © 2012 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
            Bookmark
            • Record: found
            • Abstract: not found
            • Article: not found

            Biometry of 7,500 cataractous eyes.

              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Correcting astigmatism with toric intraocular lenses: effect of posterior corneal astigmatism.

              To evaluate the impact of posterior corneal astigmatism on outcomes with toric intraocular lenses (IOLs). Cullen Eye Institute, Baylor College of Medicine, Houston, Texas, USA. Case series. Corneal astigmatism was measured using 5 devices before and 3 weeks after cataract surgery. Toric IOL alignment was recorded at surgery and at the slitlamp 3 weeks postoperatively. The actual corneal astigmatism was calculated based on refractive astigmatism 3 weeks postoperatively and the effective toric power calculated with the Holladay 2 formula. The prediction error was calculated as the difference between the astigmatism measured by each device and the actual corneal astigmatism. Vector analysis was used in all calculations. With the IOLMaster, Lenstar, Atlas, manual keratometer, and Galilei (combined Placido-dual Scheimpflug analyzer), the mean prediction errors (D) were, respectively, 0.59 @ 89.7, 0.48 @ 91.2, 0.51 @ 78.7, 0.62 @ 97.2, and 0.57 @ 93.9 for with-the-rule (WTR) astigmatism (60 to 120 degrees), and 0.17 @ 86.2, 0.23 @ 77.7, 0.23 @ 91.4, 0.41 @ 58.4, and 0.12 @ 7.3 for against-the-rule (ATR) astigmatism (0 to 30 degrees and 150 to 180 degrees). In the WTR eyes, there were significant WTR prediction errors (0.5 to 0.6 diopters [D]) by all devices. In ATR eyes, WTR prediction errors were 0.2 to 0.3 D by all devices except the Placido-dual Scheimpflug analyzer (all P<.05 with Bonferroni correction). Corneal astigmatism was overestimated in WTR by all devices and underestimated in ATR by all except the Placido-dual Scheimpflug analyzer. A new toric IOL nomogram is proposed. Copyright © 2013 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
                Bookmark

                Author and article information

                Contributors
                whitee11@naver.com
                82-2-3779-1848 , sara514@catholic.ac.kr
                Journal
                BMC Ophthalmol
                BMC Ophthalmol
                BMC Ophthalmology
                BioMed Central (London )
                1471-2415
                8 February 2017
                8 February 2017
                2017
                : 17
                : 10
                Affiliations
                Department of Ophthalmology, Yeouido St. Mary’s Hospital, College of Medicine, The Catholic University of Korea, 62 Yeouido-dong, Yeongdeungpo-gu, Seoul 150-713 Korea
                Article
                399
                10.1186/s12886-017-0399-1
                5299668
                28178925
                7dee846a-f23e-4ce6-a0d0-31e39ff65ac9
                © The Author(s). 2017

                Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License ( http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver ( http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.

                History
                : 13 November 2015
                : 9 January 2017
                Categories
                Research Article
                Custom metadata
                © The Author(s) 2017

                Ophthalmology & Optometry
                steep meridian incision,cataract surgery,posterior corneal astigmatism,shifting of steep axis

                Comments

                Comment on this article