25
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: found
      Is Open Access

      Non-Invasive Measurement of Skin Microvascular Response during Pharmacological and Physiological Provocations

      research-article

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Introduction

          Microvascular changes in the skin due to pharmacological and physiological provocations can be used as a marker for vascular function. While laser Doppler flowmetry (LDF) has been used extensively for measurement of skin microvascular responses, Laser Speckle Contrast Imaging (LSCI) and Tissue Viability Imaging (TiVi) are novel imaging techniques. TiVi measures red blood cell concentration, while LDF and LSCI measure perfusion. Therefore, the aim of this study was to compare responses to provocations in the skin using these different techniques.

          Method

          Changes in skin microcirculation were measured in healthy subjects during (1) iontophoresis of sodium nitroprusside (SNP) and noradrenaline (NA), (2) local heating and (3) post-occlusive reactive hyperemia (PORH) using LDF, LSCI and TiVi.

          Results

          Iontophoresis of SNP increased perfusion (LSCI: baseline 40.9±6.2 PU; 10-min 100±25 PU; p<0.001) and RBC concentration (TiVi: baseline 119±18; 10-min 150±41 AU; p = 0.011). No change in perfusion (LSCI) was observed after iontophoresis of NA (baseline 38.0±4.4 PU; 10-min 38.9±5.0 PU; p = 0.64), while RBC concentration decreased (TiVi: baseline 59.6±11.8 AU; 10-min 54.4±13.3 AU; p = 0.021). Local heating increased perfusion (LDF: baseline 8.8±3.6 PU; max 112±55 PU; p<0.001, LSCI: baseline 50.8±8.0 PU; max 151±22 PU; p<0.001) and RBC concentration (TiVi: baseline 49.2±32.9 AU; max 99.3±28.3 AU; p<0.001). After 5 minutes of forearm occlusion with prior exsanguination, a decrease was seen in perfusion (LDF: p = 0.027; LSCI: p<0.001) and in RBC concentration (p = 0.045). Only LSCI showed a significant decrease in perfusion after 5 minutes of occlusion without prior exsanguination (p<0.001). Coefficients of variation were lower for LSCI and TiVi compared to LDF for most responses.

          Conclusion

          LSCI is more sensitive than TiVi for measuring microvascular changes during SNP-induced vasodilatation and forearm occlusion. TiVi is more sensitive to noradrenaline-induced vasoconstriction. LSCI and TiVi show lower inter-subject variability than LDF. These findings are important to consider when choosing measurement techniques for studying skin microvascular responses.

          Related collections

          Most cited references40

          • Record: found
          • Abstract: found
          • Article: not found

          Laser speckle contrast imaging: theoretical and practical limitations.

          When laser light illuminates a diffuse object, it produces a random interference effect known as a speckle pattern. If there is movement in the object, the speckles fluctuate in intensity. These fluctuations can provide information about the movement. A simple way of accessing this information is to image the speckle pattern with an exposure time longer than the shortest speckle fluctuation time scale-the fluctuations cause a blurring of the speckle, leading to a reduction in the local speckle contrast. Thus, velocity distributions are coded as speckle contrast variations. The same information can be obtained by using the Doppler effect, but producing a two-dimensional Doppler map requires either scanning of the laser beam or imaging with a high-speed camera: laser speckle contrast imaging (LSCI) avoids the need to scan and can be performed with a normal CCD- or CMOS-camera. LSCI is used primarily to map flow systems, especially blood flow. The development of LSCI is reviewed and its limitations and problems are investigated.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Wavelet analysis of oscillations in the peripheral blood circulation measured by laser Doppler technique.

            The wavelet transform technique, a time-frequency method with logarithmic frequency resolution, was used to analyze oscillations in human peripheral blood flow measured by laser Doppler flowmetry. The oscillations extended over a wide frequency scale and their periods varied in time. Within the frequency range studied, 0.0095-1.6 Hz, five characteristic oscillations were revealed, arising from both local and central regulatory mechanisms. After the insertion of endothelium-dependent and endothelium-independent vasodilators the spectra of blood flow markedly differed in the frequency interval 0.0095-0.02 Hz. In this way it was demonstrated that endothelial activity is a rhythmic process that contributes to oscillations in blood flow with a characteristic frequency of around 0.01 Hz. The study illustrates the potential of laser Doppler flowmetry combined with dynamical systems analysis for studies of both the micro- and macroscopic mechanisms of blood flow regulation in vivo.
              Bookmark
              • Record: found
              • Abstract: not found
              • Article: not found

              The human cutaneous circulation as a model of generalized microvascular function.

                Bookmark

                Author and article information

                Contributors
                Role: Editor
                Journal
                PLoS One
                PLoS ONE
                plos
                plosone
                PLoS ONE
                Public Library of Science (San Francisco, CA USA )
                1932-6203
                13 August 2015
                2015
                : 10
                : 8
                : e0133760
                Affiliations
                [1 ]Department of Clinical and Experimental Medicine, Linköping University, Linköping, Sweden
                [2 ]Department of Plastic Surgery, Hand Surgery, and Burns, Linköping University, Linköping, Sweden
                [3 ]Department of Radiation Physics, Linköping University, Linköping, Sweden
                Université Claude Bernard Lyon 1, FRANCE
                Author notes

                Competing Interests: FS has a role in the commercialization of the polarisation spectroscopy instrumentation. This does not alter the authors' adherence to PLOS ONE policies on sharing data and materials.

                Conceived and designed the experiments: FI FS SF ET. Performed the experiments: FI AL. Analyzed the data: FI AL SF ET. Contributed reagents/materials/analysis tools: FI AL FS SF ET. Wrote the paper: FI AL FS SF ET.

                Article
                PONE-D-15-07939
                10.1371/journal.pone.0133760
                4536230
                26270037
                7fd443f8-703c-4c9a-8019-8247aae66ca3
                Copyright @ 2015

                This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited

                History
                : 21 February 2015
                : 1 July 2015
                Page count
                Figures: 4, Tables: 4, Pages: 15
                Funding
                The authors received no specific funding for this work.
                Categories
                Research Article
                Custom metadata
                All relevant data are within the paper and its Supporting Information files.

                Uncategorized
                Uncategorized

                Comments

                Comment on this article