      Assessment of global myocardial perfusion reserve using cardiovascular magnetic resonance of coronary sinus flow at 3 Tesla

      research-article

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Background

          Despite increasing clinical use, there is limited data regarding regadenoson in stress perfusion cardiovascular magnetic resonance (CMR). In particular, given its long half-life the optimal stress protocol remains unclear. Although Myocardial Perfusion Reserve (MPR) may provide additive prognostic information, current techniques for its measurement are cumbersome and challenging for routine clinical practice.

          The aims of this study were: 1) To determine the feasibility of MPR quantification during regadenoson stress CMR by measurement of Coronary Sinus (CS) flow; and 2) to investigate the role of aminophylline reversal during regadenoson stress-CMR.

          Methods

          117 consecutive patients with possible myocardial ischemia were prospectively enrolled. Perfusion imaging was performed at 1 minute and 15 minutes after administration of 0.4 mg regadenoson. A subgroup of 41 patients was given aminophylline (100 mg) after stress images were acquired. CS flow was measured using phase-contrast imaging at baseline (pre CS flow), and immediately after the stress (peak CS flow) and rest (post CS flow) perfusion images.

          Results

          CS flow measurements were obtained in 92% of patients with no adverse events. MPR was significantly underestimated when calculated as peak CS flow/post CS flow as compared to peak CS flow/pre CS flow (2.43 ± 0.20 vs. 3.28 ± 0.32, p = 0.03). This difference was abolished when aminophylline was administered (3.35 ± 0.44 vs. 3.30 ± 0.52, p = 0.95). Impaired MPR (peak CS flow/pre CS flow <2) was associated with advanced age, diabetes, current smoking and higher Framingham risk score.

          Conclusions

          Regadenoson stress CMR with MPR measurement from CS flow can be successfully performed in most patients. This measurement of MPR appears practical to perform in the clinical setting. Residual hyperemia is still present even 15 minutes after regadenoson administration, at the time of resting-perfusion acquisition, and is completely reversed by aminophylline. Our findings suggest routine aminophylline administration may be required when performing stress CMR with regadenoson.

          Related collections

          Most cited references20

          • Record: found
          • Abstract: found
          • Article: not found

          Statistical methods for assessing agreement between two methods of clinical measurement.

          In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Improved detection of coronary artery disease by stress perfusion cardiovascular magnetic resonance with the use of delayed enhancement infarction imaging.

            We tested a pre-defined visual interpretation algorithm that combines cardiovascular magnetic resonance (CMR) data from perfusion and infarction imaging for the diagnosis of coronary artery disease (CAD). Cardiovascular magnetic resonance can assess both myocardial perfusion and infarction with independent techniques in a single session. We prospectively enrolled 100 consecutive patients with suspected CAD scheduled for X-ray coronary angiography. Patients had comprehensive clinical evaluation, including Rose angina questionnaire, 12-lead electrocardiography, C-reactive protein, and calculation of Framingham risk. Cardiovascular magnetic resonance included cine, adenosine-stress and rest perfusion-CMR, and delayed enhancement-CMR (DE-CMR) for infarction imaging. Matched stress-rest perfusion defects in the absence of infarction by DE-CMR were considered artifactual. All patients underwent X-ray angiography within 24 h of CMR. Ninety-two patients had complete CMR examinations. Significant CAD (> or =70% stenosis) was found in 37 patients (40%). The combination of perfusion and DE-CMR had a sensitivity, specificity, and accuracy of 89%, 87%, and 88%, respectively, for CAD diagnosis, compared with 84%, 58%, and 68%, respectively, for perfusion-CMR alone. The combination had higher specificity and accuracy (p < 0.0001), owing to incorporating the exceptionally high specificity (98%) of DE-CMR. Receiver operating characteristic curve analysis demonstrated the combination provided better performance than cine, perfusion, or DE-CMR alone. The accuracy was high in single-vessel and multivessel disease and independent of CAD location. Multivariable analysis including standard clinical parameters demonstrated the combination was the strongest independent CAD predictor. A combined perfusion and infarction CMR examination with a visual interpretation algorithm can accurately diagnose CAD in the clinical setting. The combination is superior to perfusion-CMR alone.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Regadenoson: a new myocardial stress agent.

              Vasodilator stress myocardial perfusion imaging (MPI) accounts for up to 50% of all stress MPI studies performed in the U.S. In 2008, the Food and Drug Administration approved regadenoson for stress testing in conjunction with MPI. Regadenoson, unlike adenosine, is a selective A(2A) agonist that is given as an intravenous bolus at a fixed dose, with less undesirable side effects including atrioventricular block and bronchospasm. Unlike adenosine, regadenoson could be used in patients with mild-to-moderate reactive airway disease. This review will summarize the pre-clinical and clinical data on regadenoson, as they specifically relate to its use as a vasodilator stress agent, currently the only approved selective A(2A) agonist.
                Bookmark

                Author and article information

                Contributors
                Journal
                J Cardiovasc Magn Reson
                J Cardiovasc Magn Reson
                Journal of Cardiovascular Magnetic Resonance
                BioMed Central
                1097-6647
                1532-429X
                2014
                27 March 2014
                : 16
                : 1
                : 24
                Affiliations
                [1 ]Section of Cardiology, Department of Medicine, University of Illinois at Chicago, 840 South Wood St. M/C 715, Suite 920 S, Chicago, IL 60612, USA
                [2 ]National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda MD, USA
                [3 ]Department of Radiology, University of Illinois at Chicago, Chicago, IL, USA
                [4 ]Division of Cardiology, Department of Medicine, Duke University, Durham, NC, USA
                Article
                1532-429X-16-24
                10.1186/1532-429X-16-24
                3977939
                24674383
                85e4a394-3090-4f22-9ab3-1e1da6768b4a
                Copyright © 2014 Dandekar et al.; licensee BioMed Central Ltd.

                This is an Open Access article distributed under the terms of the Creative Commons Attribution License ( http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited. The Creative Commons Public Domain Dedication waiver ( http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.

                History
                : 19 November 2013
                : 3 March 2014
                Categories
                Research

                Cardiovascular Medicine
                cardiovascular magnetic resonance,stress testing,perfusion,regadenoson
                Cardiovascular Medicine
                cardiovascular magnetic resonance, stress testing, perfusion, regadenoson

                Comments

                Comment on this article