11
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: found
      Is Open Access

      Paper-based upconversion fluorescence resonance energy transfer biosensor for sensitive detection of multiple cancer biomarkers

      research-article

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          A paper-based upconversion fluorescence resonance energy transfer assay device is proposed for sensitive detection of CEA. The device is fabricated on a normal filter paper with simple nano-printing method. Upconversion nanoparticles tagged with specific antibodies are printed to the test zones on the test paper, followed by the introduction of assay antigen. Upconversion fluorescence measurements are directly conducted on the test zones after the antigen-to-antibody reactions. Furthermore, a multi-channel test paper for simultaneous detection of multiple cancer biomarkers was established by the same method and obtained positive results. The device showed high anti-interfere, stability, reproducible and low detection limit (0.89 ng/mL), moreover it is very easy to fabricate and operate, which is a promising prospect for a clinical point-of-care test.

          Related collections

          Most cited references22

          • Record: found
          • Abstract: found
          • Article: not found

          Diagnostics for the developing world: microfluidic paper-based analytical devices.

          Microfluidic paper-based analytical devices (microPADs) are a new class of point-of-care diagnostic devices that are inexpensive, easy to use, and designed specifically for use in developing countries. (To listen to a podcast about this feature, please go to the Analytical Chemistry multimedia page at pubs.acs.org/page/ancham/audio/index.html.).
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Upconversion multicolor fine-tuning: visible to near-infrared emission from lanthanide-doped NaYF4 nanoparticles.

            A general approach to fine-tuning the upconversion emission colors, based upon a single host source of NaYF4 nanoparticles doped with Yb3+, Tm3+, and Er3+, is presented. The emission intensity balance can be precisely controlled using different host-activator systems and dopant concentrations. The approach allows access to a wide range of luminescence emission from visible to near-infrared by single-wavelength excitation.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Aptamer biosensor based on fluorescence resonance energy transfer from upconverting phosphors to carbon nanoparticles for thrombin detection in human plasma.

              We presented a new aptamer biosensor for thrombin in this work, which was based on fluorescence resonance energy transfer (FRET) from upconverting phosphors (UCPs) to carbon nanoparticles (CNPs). The poly(acrylic acid) (PAA) functionalized UCPs were covalently tagged with a thrombin aptamer (5'-NH(2)- GGTTGGTGTGGTTGG-3'), which bound to the surface of CNPs through π-π stacking interaction. As a result, the energy donor and acceptor were taken into close proximity, leading to the quenching of fluorescence of UCPs. A maximum fluorescence quenching rate of 89% was acquired under optimized conditions. In the presence of thrombin, which induced the aptamer to form quadruplex structure, the π-π interaction was weakened, and thus, the acceptor was separated from the donor blocking the FRET process. The fluorescence of UCPs was therefore restored in a thrombin concentration-dependent manner, which built the foundation of thrombin quantification. The sensor provided a linear range from 0.5 to 20 nM for thrombin with a detection limit of 0.18 nM in an aqueous buffer. The same linear range was obtained in spiked human serum samples with a slightly higher detection limit (0.25 nM), demonstrating high robustness of the sensor in a complex biological sample matrix. As a practical application, the sensor was used to monitor thrombin level in human plasma with satisfactory results obtained. This is the first time that UCPs and CNPs were employed as a donor-acceptor pair to construct FRET-based biosensors, which utilized both the photophysical merits of UCPs and the superquenching ability of CNPs and thus afforded favorable analytical performances. This work also opened the opportunity to develop biosensors for other targets using this UCPs-CNPs system.
                Bookmark

                Author and article information

                Journal
                Sci Rep
                Sci Rep
                Scientific Reports
                Nature Publishing Group
                2045-2322
                22 March 2016
                2016
                : 6
                : 23406
                Affiliations
                [1 ]State Key Laboratory on Integrated Optoelectronics, College of Electronic Science and Engineering, Jilin University , Changchun 130012, People’s Republic of China
                [2 ]Department of Physics, Dalian Maritime University , Dalian 116026, People’s Republic of China
                Author notes
                Article
                srep23406
                10.1038/srep23406
                4802215
                27001460
                8625f08d-c8a5-4f08-a474-c7ff667e5533
                Copyright © 2016, Macmillan Publishers Limited

                This work is licensed under a Creative Commons Attribution 4.0 International License. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in the credit line; if the material is not included under the Creative Commons license, users will need to obtain permission from the license holder to reproduce the material. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/

                History
                : 18 December 2015
                : 02 March 2016
                Categories
                Article

                Uncategorized
                Uncategorized

                Comments

                Comment on this article