      Assessment of the Accuracy, Usability and Acceptability of a Rapid Test for the Simultaneous Diagnosis of Syphilis and HIV Infection in a Real-Life Scenario in the Amazon Region, Brazil

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          We field-assessed the accuracy, acceptability, and feasibility of the SD BIOLINE HIV/Syphilis Duo rapid diagnostic test in three groups: pregnant women, female sex workers (FSW), and men who have sex with men (MSM). Venous blood samples collected in the field were compared with the respective gold standard methods: SD BIOLINE HIV/Syphilis Duo Treponemal Test versus FTA-abs (Wama brand) treponemal laboratory test for syphilis, and SD BIOLINE HIV/Syphilis Duo Test versus the fourth generation Genscreen Ultra HIV Ag-Ag (Bio-Rad brand) laboratory test for HIV. From a total of 529 participants, 397 (75.1%) were pregnant women, 76 (14.3%) FSW and 56 (10.6%) MSM. Sensitivity and specificity parameters of HIV were 100.0% (95% CI: 82.35–100.0%) and 100.0% (95% CI: 99.28–100.0%), respectively. Sensitivity and specificity parameters found for TP antibody detection were 95.00% (95% CI: 87.69–98.62%) and 100.0% (95% CI: 98.18–100.0%), respectively. The SD BIOLINE HIV/Syphilis Duo Test showed high acceptability among participants (85.87%) and health professionals (85.51%), as well as easy usability by professionals (91.06%). The usability of the SD BIOLINE HIV/Syphilis Duo Test kit would not be a barrier to accessing rapid testing, if the product were incorporated into the list of health service supplies.

          Related collections

          Most cited references17

          • Record: found
          • Abstract: found
          • Article: found
          Is Open Access

          Laboratory evaluation of four HIV/syphilis rapid diagnostic tests

          Background Sexually transmitted infections, such as HIV and syphilis, are one of the major health care problems worldwide, especially in low- and middle income countries. HIV screening programmes have been widely used for many years. The introduction of rapid point-of-care tests (RDTs) that can detect both HIV and syphilis, using one single blood specimen, would be a promising tool to integrate the detection of syphilis into HIV programmes and so improve the accessibility of syphilis testing and treatment. Methods As part of the World Health Organization pre-qualification of in vitro diagnostics assessment, the laboratory performance of four dual HIV-Syphilis rapid diagnostic tests (SD Bioline HIV/Syphilis Duo, DPP HIV-Syphilis Assay, Multiplo Rapid TP/HIV Antibody Test and Insti Multiplex HIV-1/HIV-2/Syphilis Antibody Test) was assessed using a well characterized multiregional panel of stored sera specimens. Results In total 400 specimens were tested with each assay, resulting in excellent sensitivities and specificities for HIV, ranging from 99.5 to 100% and from 93.5 to 99.5%, respectively. Results obtained for the Treponema pallidum antibodies were lower, with the lowest sensitivity of 73.5% for Multiplo and the highest of 87% for SD Bioline. Specificities ranged from 99.0 to 100%. Conclusion Although these results suggest that the tests could further improve in accuracy in detection of treponemal antibodies, their introduction into screening programmes to increase the accessibility of HIV/Syphilis diagnosis and treatment for difficult to reach populations in the world is promising.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Field evaluation of a dual rapid diagnostic test for HIV infection and syphilis in Lima, Peru.

            Screening for HIV and syphilis in key populations is recommended by the WHO to reduce the morbidity, mortality and transmission associated with undiagnosed and untreated infections. Rapid point-of-care tests that can detect multiple infections with a single fingerprick whole blood specimen using a single device are gaining popularity. We evaluated the field performance of a rapid dual HIV and syphilis test in people at high risk of HIV and syphilis infections.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Field evaluation of Standard Diagnostics' Bioline HIV/Syphilis Duo test among female sex workers in Johannesburg, South Africa.

              Point-of-care tests provide immediate results with the opportunity for same-day interventions with improved public health outcomes. A dual HIV/syphilis test enables early treatment of both diseases.
                Bookmark

                Author and article information

                Contributors
                (View ORCID Profile)
                (View ORCID Profile)
                (View ORCID Profile)
                (View ORCID Profile)
                (View ORCID Profile)
                (View ORCID Profile)
                Journal
                DIAGC9
                Diagnostics
                Diagnostics
                MDPI AG
                2075-4418
                February 2023
                February 20 2023
                : 13
                : 4
                : 810
                Article
                10.3390/diagnostics13040810
                8e7f0489-acbb-40df-a2c2-6ed4fc8e6997
                © 2023

                https://creativecommons.org/licenses/by/4.0/

                History

                Comments

                Comment on this article