      Feasibility of Swept Synthetic Aperture Ultrasound Imaging

      Read this article at

      ScienceOpenPublisherPMC
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          <p class="first" id="P1">Ultrasound image quality is often inherently limited by the physical dimensions of the imaging transducer. We hypothesize that, by collecting synthetic aperture data sets over a range of aperture positions while precisely tracking the position and orientation of the transducer, we can synthesize large effective apertures to produce images with improved resolution and target detectability. We analyze the two largest limiting factors for coherent signal summation: aberration and mechanical uncertainty. Using an excised canine abdominal wall as a model phase screen, we experimentally observed an effective arrival time error ranging from 18.3 ns to 58 ns (root-mean-square error) across the swept positions. Through this clutter-generating tissue, we observed a 72.9% improvement in resolution with only a 3.75 dB increase in side lobe amplitude compared to the control case. We present a simulation model to study the effect of calibration and mechanical jitter errors on the synthesized point spread function. The relative effects of these errors in each imaging dimension are explored, showing the importance of orientation relative to the point spread function. We present a prototype device for performing swept synthetic aperture imaging using a conventional 1-D array transducer and ultrasound research scanner. Point target reconstruction error for a 44.2 degree sweep shows a reconstruction precision of 82.8 <i>μ</i>m and 17.8 <i>μ</i>m in the lateral and axial dimensions respectively, within the acceptable performance bounds of the simulation model. Improvements in resolution, contrast and contrast-to-noise ratio are demonstrated <i>in vivo</i> and in a fetal phantom. </p>

          Related collections

          Author and article information

          Journal
          IEEE Transactions on Medical Imaging
          IEEE Trans. Med. Imaging
          Institute of Electrical and Electronics Engineers (IEEE)
          0278-0062
          1558-254X
          July 2016
          July 2016
          : 35
          : 7
          : 1676-1685
          Article
          10.1109/TMI.2016.2524992
          5485828
          26863653
          8ffec908-2fa4-4b5c-9c77-7e30d3b88ea3
          © 2016
          History

          Comments

          Comment on this article