      Results of 1 year of clinical experience with independent dose calculation software for VMAT fields

      research-article

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          It is widely accepted that a redundant independent dose calculation (RIDC) must be included in any treatment planning verification procedure. Specifically, volumetric modulated arc therapy (VMAT) technique implies a comprehensive quality assurance (QA) program in which RIDC should be included. In this paper, the results obtained in 1 year of clinical experience are presented. Eclipse from Varian is the treatment planning system (TPS), here in use. RIDC were performed with the commercial software; Diamond ® (PTW) which is capable of calculating VMAT fields. Once the plan is clinically accepted, it is exported via Digital Imaging and Communications in Medicine (DICOM) to RIDC, together with the body contour, and then a point dose calculation is performed, usually at the isocenter. A total of 459 plans were evaluated. The total average deviation was -0.3 ± 1.8% (one standard deviation (1SD)). For higher clearance the plans were grouped by location in: Prostate, pelvis, abdomen, chest, head and neck, brain, stereotactic radiosurgery, lung stereotactic body radiation therapy, and miscellaneous. The highest absolute deviation was -0.8 ± 1.5% corresponding to the prostate. A linear fit between doses calculated by RIDC and by TPS produced a correlation coefficient of 0.9991 and a slope of 1.0023. These results are very close to those obtained in the validation process. This agreement led us to consider this RIDC software as a valuable tool for QA in VMAT plans.

          Related collections

          Most cited references17

          • Record: found
          • Abstract: found
          • Article: not found

          IMRT commissioning: multiple institution planning and dosimetry comparisons, a report from AAPM Task Group 119.

          AAPM Task Group 119 has produced quantitative confidence limits as baseline expectation values for IMRT commissioning. A set of test cases was developed to assess the overall accuracy of planning and delivery of IMRT treatments. Each test uses contours of targets and avoidance structures drawn within rectangular phantoms. These tests were planned, delivered, measured, and analyzed by nine facilities using a variety of IMRT planning and delivery systems. Each facility had passed the Radiological Physics Center credentialing tests for IMRT. The agreement between the planned and measured doses was determined using ion chamber dosimetry in high and low dose regions, film dosimetry on coronal planes in the phantom with all fields delivered, and planar dosimetry for each field measured perpendicular to the central axis. The planar dose distributions were assessed using gamma criteria of 3%/3 mm. The mean values and standard deviations were used to develop confidence limits for the test results using the concept confidence limit = /mean/ + 1.96sigma. Other facilities can use the test protocol and results as a basis for comparison to this group. Locally derived confidence limits that substantially exceed these baseline values may indicate the need for improved IMRT commissioning.
            Bookmark
            • Record: found
            • Abstract: not found
            • Article: not found

            Comprehensive QA for radiation oncology: report of AAPM Radiation Therapy Committee Task Group 40.

              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Guidance document on delivery, treatment planning, and clinical implementation of IMRT: report of the IMRT Subcommittee of the AAPM Radiation Therapy Committee.

              Intensity-modulated radiation therapy (IMRT) represents one of the most significant technical advances in radiation therapy since the advent of the medical linear accelerator. It allows the clinical implementation of highly conformal nonconvex dose distributions. This complex but promising treatment modality is rapidly proliferating in both academic and community practice settings. However, these advances do not come without a risk. IMRT is not just an add-on to the current radiation therapy process; it represents a new paradigm that requires the knowledge of multimodality imaging, setup uncertainties and internal organ motion, tumor control probabilities, normal tissue complication probabilities, three-dimensional (3-D) dose calculation and optimization, and dynamic beam delivery of nonuniform beam intensities. Therefore, the purpose of this report is to guide and assist the clinical medical physicist in developing and implementing a viable and safe IMRT program. The scope of the IMRT program is quite broad, encompassing multileaf-collimator-based IMRT delivery systems, goal-based inverse treatment planning, and clinical implementation of IMRT with patient-specific quality assurance. This report, while not prescribing specific procedures, provides the framework and guidance to allow clinical radiation oncology physicists to make judicious decisions in implementing a safe and efficient IMRT program in their clinics.
                Bookmark

                Author and article information

                Journal
                J Med Phys
                J Med Phys
                JMP
                Journal of Medical Physics / Association of Medical Physicists of India
                Medknow Publications & Media Pvt Ltd (India )
                0971-6203
                1998-3913
                Oct-Dec 2014
                : 39
                : 4
                : 219-224
                Affiliations
                [1]Department of Medical Physics, Santa Lucia Universitary Hospital, Cartagena, Spain
                [1 ]Department of Radiology and Physical Medicine, Faculty of Medicine, University of Murcia, Spain
                Author notes
                Address for correspondence: Mr. Juan Fernando Mata Colodro, Mezquita s/n. 30202, Cartagena, Spain. E-mail: jfmata@ 123456gmail.com
                Article
                JMP-39-219
                10.4103/0971-6203.144485
                4258729
                25525309
                9040be83-6b3e-48a6-b512-e4ddf51e27d0
                Copyright: © Journal of Medical Physics

                This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

                History
                : 28 May 2014
                : 12 October 2014
                : 15 October 2014
                Categories
                Original Article

                Medical physics
                clinical experience,diamond,redundant independent calculation,vmat
                Medical physics
                clinical experience, diamond, redundant independent calculation, vmat

                Comments

                Comment on this article