5
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: not found

      Validity of GT3X and Actiheart to estimate sedentary time and breaks using ActivPAL as the reference in free-living conditions.

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Sedentary time, specifically sitting/reclining, is a risk factor for many non-communicable diseases and premature mortality. Inclinometers have been used as a valid measurement of sedentary time and its patterns; however, there is a lack of information regarding the validity of alternative accelerometry and heart rate methods. The validity of GT3X and Actiheart in estimating changes in daily sedentary time and breaks, during free-living settings, using ActivPAL as the reference was examined. A crossover randomized control trial of an intervention that aimed to reduce ∼3 h/day of sitting time included 10 overweight/obese adults (37-65 years). Participants had a total of 74 valid days for the three devices (29 controls; 45 interventions). For ActivPAL, sedentary time was measured directly based upon posture (sitting/reclining); Actiheart, the presumed MET cutpoint for sedentary time (<1.5 METs) based on accelerometry+heart rate; GT3X, the traditional <100countsmin(-1). A break in sedentary time was defined as when the participants were above the aforementioned cutoffs. GT3X overestimated and Actiheart underestimated sedentary time (bias=135min; bias=-156min, respectively) and both methods overestimated breaks in sedentary time (bias=78; bias=235 breaks, respectively). The GT3X method was in better agreement with the ActivPAL sedentary time (r2=0.70; concordance correlation coefficient (CCC)=0.56) than the Actiheart (r2=0.24; CCC=0.31). The present results highlight the magnitude of potential errors in estimating sedentary time and breaks from common alternative methods other than ActivPAL. Because misclassification errors from the commonly used surrogates are potentially large, this raises concern that alternative methods used in many epidemiological observations may have underestimated the true effects caused by too much sitting (ClinicalTrials.govID:NCT02007681).

          Related collections

          Author and article information

          Journal
          Gait Posture
          Gait & posture
          1879-2219
          0966-6362
          May 2015
          : 41
          : 4
          Affiliations
          [1 ] Universidade de Lisboa, Exercise and Health Laboratory, Interdisciplinary Center for the Study of Human Performance, Faculdade de Motricidade Humana, Estrada da Costa 1499-002 Cruz-Quebrada, Portugal. Electronic address: pedrojudice@fmh.ulisboa.pt.
          [2 ] Universidade de Lisboa, Exercise and Health Laboratory, Interdisciplinary Center for the Study of Human Performance, Faculdade de Motricidade Humana, Estrada da Costa 1499-002 Cruz-Quebrada, Portugal. Electronic address: dianasantos@fmh.ulisboa.pt.
          [3 ] Pennington Biomedical Research Center, Baton Rouge, LA, USA. Electronic address: Marc.Hamilton@pbrc.edu.
          [4 ] Universidade de Lisboa, Exercise and Health Laboratory, Interdisciplinary Center for the Study of Human Performance, Faculdade de Motricidade Humana, Estrada da Costa 1499-002 Cruz-Quebrada, Portugal. Electronic address: lsardinha@fmh.utl.pt.
          [5 ] Universidade de Lisboa, Exercise and Health Laboratory, Interdisciplinary Center for the Study of Human Performance, Faculdade de Motricidade Humana, Estrada da Costa 1499-002 Cruz-Quebrada, Portugal. Electronic address: analiza@fmh.utl.pt.
          Article
          S0966-6362(15)00406-3
          10.1016/j.gaitpost.2015.03.326
          25852024
          980b89ad-a0d7-41e3-a158-a41140935e55
          Copyright © 2015 Elsevier B.V. All rights reserved.
          History

          Inclinometer,Intervention,Motion sensor,Objective methods,Sedentary patterns

          Comments

          Comment on this article