      Concentration of metal elements in the blood and urine in the patients with cementless total knee arthroplasty.

      The Tohoku journal of experimental medicine
      Aged, Arthritis, surgery, Arthroplasty, Replacement, Knee, adverse effects, Chromium, blood, urine, Cobalt, Female, Humans, Knee Prosthesis, Male, Matched-Pair Analysis, Metals, Light, Middle Aged, Prosthesis Failure, Titanium

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Titanium (Ti), cobalt (Co) and chromium (Cr) element concentrations in the whole blood and urine specimen in 40 patients with cementless total knee arthroplasty were determined by the electrothermal atomic absorption spectrophotometry. Their ages ranged from 55 to 78 years (mean, 65 years). Twenty of them had loosening of prosthesis and underwent revision surgery, including 4 subjects with Ti-6Al-4V alloy prosthesis and 16 subjects with Co-Cr-Mo alloy prosthesis. The other 20 patients had well-functioning stable prosthesis, including 5 subjects with Ti-6Al-4V alloy prosthesis and 15 subjects with Co-Cr-Mo alloy prosthesis. The mean duration of prostheses implantation in patients with loosened or well-functioning prostheses were 6.5 and 4.0 years, respectively. The control group consisted of 20 age-matched normal subjects who did not undergo any metal implant surgery. Analysis of variance showed that the metal element concentrations in the whole blood, either Co, Cr or Ti, was statistically higher in the patients with loosened prosthesis than the other two groups. However, the metal element concentrations in the urine did not show any difference. The linear regression analysis showed a moderate positive relationship between the metal element concentrations, either Co or Cr elements, in whole blood and urine only in the patients with loosened prostheses. In conclusion, elevated concentration of metal elements may indicate a loosening of prosthesis while the clinical significance of the metal element concentration in the urine needs further investigation.

          Related collections

          Author and article information

          Comments

          Comment on this article