6
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: not found
      • Article: not found

      The Atom‐Probe Field Ion Microscope

      , ,
      Review of Scientific Instruments
      AIP Publishing

      Read this article at

      ScienceOpenPublisher
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Related collections

          Most cited references6

          • Record: found
          • Abstract: found
          • Article: not found

          Scanning electron microscopes: is high resolution possible?

          A Crewe (1966)
          Experiments with this scanning microscope have produced extremely encouraging results so that we feel Confident in predicting high resolution and high contrast after some obvious modifications are made in the system, such as providing a good objective lens. Experience with conventional lenses indicates that the instrument behaves in a predictable manner and there is no reason to doubt that the resolution can be as good as that of a conventional microscope. The use of quadrupole lenses will depend on calculations now being performed. There is cause for optimism; high resolution may also be possible with this kind of lens. Experience with field emission shows that the technology is not difficult and that there is more than enough current available for any conceivable use. Energy-loss measurements have been made on a variety of materials. It is attractive to consider the possibility of chemical analysis of selected areas of a specimen. We believe that a very crude form of analysis may indeed be possible. The principal advantage of the use of energy-loss techniques, however, may be in the availability of another contrast mechanism. The ability to "see" small details may be considerably enhanced. Finally, we are experimenting with the possibility of using transmitted electrons of different energy losses to produce different colors on a color television display. This should add an extra element to the picture contrast which may be of some value.
            Bookmark
            • Record: found
            • Abstract: not found
            • Article: not found

            Field Ion Microscopy.

            E Müller (1965)
              Bookmark
              • Record: found
              • Abstract: not found
              • Article: not found

              Corrosion of Tungsten and Iridium by Field Desorption of Nitrogen and Carbon Monoxide

                Bookmark

                Author and article information

                Journal
                Review of Scientific Instruments
                Review of Scientific Instruments
                AIP Publishing
                0034-6748
                1089-7623
                January 1968
                January 1968
                : 39
                : 1
                : 83-86
                Article
                10.1063/1.1683116
                a2edf21a-656e-4428-940e-06f8307a2359
                © 1968
                History

                Comments

                Comment on this article