          Abstract

          For several years, the gold standard for surgical treatment of glaucoma has been trabeculectomy. Although very successful at reducing intraocular pressure (IOP), there are several potential complications of trabeculectomy, including sight-threatening ones. This has stimulated much research aimed at the development of new and effective procedures to lower IOP with an enhanced safety profile. Minimally invasive glaucoma surgery (MIGS) procedures prioritise patient safety but also demonstrate efficacy in reducing IOP. We performed an online search of peer-reviewed literature using PubMed, entering keywords relevant to this clinical discipline. In summary, there is a lack of long-term safety and efficacy data, a lack of comparative data and a lack of data on standalone (i.e. without simultaneous cataract surgery) procedures. Most implants are not yet FDA approved. Although not exhaustive, since it does not discuss MIGS procedures that are not implants, this article summarises the range of different MIGS implants that are available to the ophthalmic surgeon.

          Related collections

          Most cited references14

          • Record: found
          • Abstract: found
          • Article: not found

          Micro-invasive glaucoma surgery: current perspectives and future directions.

          There is an increasing interest and availability of micro-invasive glaucoma surgery (MIGS) procedures. It is important that this increase is supported by sound, peer-reviewed evidence. This article will define MIGS, review relevant publications in the period of annual review and discuss future directions. The results of the pivotal trial comparing a trabecular micro-bypass stent (iStent, Glaukos Corporation, Laguna Hills, CA, USA) combined with phacoemulsification to phacoemulsification alone showed a significantly higher percentage of patients with unmedicated intraocular pressure (IOP) ≤ 21 mmHg, and a comparable safety profile. Initial results are published regarding a second-generation micro-bypass stent (iStent inject, Glaukos Corporation, Laguna Hills, CA, USA), a canalicular scaffold (Hydrus, Ivantis Inc., Irvine, CA, USA) and an ab interno suprachoroidal microstent (CyPass, Transcend Medical, Menlo Park, CA, USA), showing a decrease in mean postoperative IOP. Phaco-Trabectome (Ab interno trabeculectomy Trabectome, NeoMedix Inc., Tustin, CA, USA) was compared to phacotrabeculectomy and showed less IOP reduction, less postoperative complications, and a similar success rate. Similar success rates were found with the comparison of excimer laser trabeculostomy (ELT, AIDA, Glautec AG, Nurnberg, Germany) and selective laser trabeculoplasty. A number of publications review the importance of the location of implantable devices, intraoperative gonioscopy, cost-effectiveness and quality-of-life studies, and randomized clinical trials. MIGS procedures offer reduction in IOP, decrease in dependence on glaucoma medications and an excellent safety profile. Their role within our glaucoma treatment algorithm continues to be clarified and differs from the role of more invasive glaucoma surgeries such as trabeculectomy or glaucoma drainage devices.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Randomized evaluation of the trabecular micro-bypass stent with phacoemulsification in patients with glaucoma and cataract.

            To assess the safety and efficacy of the iStent trabecular micro-bypass stent (Glaukos Corporation, Laguna Hills, CA) in combination with cataract surgery in subjects with mild to moderate open-angle glaucoma. Prospective, randomized, open-label, controlled, multicenter clinical trial. A total of 240 eyes with mild to moderate open-angle glaucoma with intraocular pressure (IOP) ≤24 mmHg controlled on 1 to 3 medications were randomized to undergo cataract surgery with iStent implantation (treatment group) or cataract surgery only (control). Fifty additional subjects were enrolled to undergo cataract surgery with iStent implantation under protocol expansion. Data in this report are based on the first 240 eyes enrolled. Implantation of the iStent trabecular micro-bypass stent in conjunction with cataract surgery or cataract surgery only. The primary efficacy measure was unmedicated IOP ≤21 mmHg at 1 year. A secondary measure was unmedicated IOP reduction ≥20% at 1 year. Safety measures included best-corrected visual acuity (BCVA), slit-lamp observations, complications, and adverse events. The study met the primary outcome, with 72% of treatment eyes versus 50% of control eyes achieving the criterion (P<0.001). At 1 year, IOP in both treatment groups was statistically significantly lower from baseline values. Sixty-six percent of treatment eyes versus 48% of control eyes achieved ≥20% IOP reduction without medication (P = 0.003). The overall incidence of adverse events was similar between groups with no unanticipated adverse device effects. Pressure reduction on fewer medications was clinically and statistically significantly better 1 year after stent plus cataract surgery versus cataract surgery alone, with an overall safety profile similar to that of cataract surgery alone. Copyright © 2011 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              The Effect of Phacoemulsification on Intraocular Pressure in Glaucoma Patients: A Report by the American Academy of Ophthalmology.

              To examine effects of phacoemulsification on longer-term intraocular pressure (IOP) in patients with medically treated primary open-angle glaucoma (POAG; including normal-tension glaucoma), pseudoexfoliation glaucoma (PXG), or primary angle-closure glaucoma (PACG), without prior or concurrent incisional glaucoma surgery.
                Bookmark

                Author and article information

                Contributors
                e.ansari@nhs.net
                Journal
                Ophthalmol Ther
                Ophthalmol Ther
                Ophthalmology and Therapy
                Springer Healthcare (Cheshire )
                2193-8245
                2193-6528
                20 July 2017
                20 July 2017
                December 2017
                : 6
                : 2
                : 233-241
                Affiliations
                [1 ]GRID grid.439813.4, Maidstone & Tunbridge Wells NHS Trust, ; Maidstone, UK
                [2 ]ISNI 0000 0001 2232 2818, GRID grid.9759.2, University of Kent, ; Canterbury, UK
                Article
                98
                10.1007/s40123-017-0098-2
                5693836
                28730285
                b22977a4-838d-40b1-9305-ad851e04d029
                © The Author(s) 2017
                History
                : 2 May 2017
                Categories
                Review
                Custom metadata
                © Springer Healthcare Ltd., part of Springer Nature 2017

                cypass,glaucoma,hydrus,implant,istent,microshunt,migs,phaco,stent,xen
                cypass, glaucoma, hydrus, implant, istent, microshunt, migs, phaco, stent, xen

                Comments

                Comment on this article