10
views
0
recommends
+1 Recommend
1 collections
    0
    shares

      Call for Papers: Artificial Intelligence in Gastroenterology

      Submit here before May 31, 2024

      About Digestion: 3.2 Impact Factor I 6.4 CiteScore I 0.914 Scimago Journal & Country Rank (SJR)

      • Record: found
      • Abstract: found
      • Article: found
      Is Open Access

      First Experiences with the New Senhance® Telerobotic System in Visceral Surgery

      review-article

      Read this article at

      ScienceOpenPublisherPMC
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Until recently, robotic-assisted surgery has exclusively been connected to the name DaVinci®. In 2016, a second robotic system, the Senhance®, became available. To introduce the new robotic system into clinical routine, detailed team training and an integration program were useful. Within the first 6 months, 116 cases were performed with this system. The integration program intended to start with simple and well-standardized clinical cases. We chose inguinal hernia repair using the TAPP (transabdominal preperitoneal) technique as the starting procedure. Subsequently, we added upper gastrointestinal surgery and cholecystectomies, and colorectal procedures have since also been included. Initial experience with the Senhance system as the first installation in Germany shows that it is suitable for surgery in general and for visceral surgery in particular. The application is safe due to the unproblematically quick changeover to normal laparoscopy and easy to integrate due to the very short system integration times (docking times). Since it is a laparoscopic-based system, following an integration program will enable experienced laparoscopic surgeons to very quickly manage more complex procedures. Due to lower costs, introducing robotic surgery starting with simple and standardized procedures is more feasible. After the establishment of this second robotic system, future studies will have to specifically look at differences in surgical results and basic conditions of different robotic-assisted systems. This paper documents the decision-making process of a hospital towards the integration of a robotic system and the selection criteria used while also demonstrating the planning and execution process during the introduction of the system into clinical routine.

          Related collections

          Author and article information

          Journal
          VIS
          VIS
          10.1159/issn.2297-4725
          Visceral Medicine
          S. Karger AG
          978-3-318-06320-2
          978-3-318-06321-9
          2297-4725
          2297-475X
          2018
          February 2018
          16 February 2018
          : 34
          : 1
          : 31-36
          Affiliations
          Department of Minimally Invasive and Robotic Surgery, Clinic for General, Visceral, and Vascular Surgery, St. Marienkrankenhaus Siegen, Siegen, Germany
          Author notes
          *Dr. med. Dietmar Stephan, Department of Minimally Invasive and Robotic Surgery, Clinic for General, Visceral, and Vascular Surgery, St. Marien Krankenhaus Siegen, Kampenstraße 51, 57078 Siegen, Germany, dietmar.stephan@stephan-siegen.de
          Article
          486111 PMC5869585 Visc Med 2018;34:31-36
          10.1159/000486111
          PMC5869585
          29594167
          b8b9c0df-da3e-48a3-8881-b624964bad34
          © 2018 The Author(s). Published by S. Karger GmbH, Freiburg

          This article is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License (CC BY-NC-ND). Usage and distribution for commercial purposes as well as any distribution of modified material requires written permission. Drug Dosage: The authors and the publisher have exerted every effort to ensure that drug selection and dosage set forth in this text are in accord with current recommendations and practice at the time of publication. However, in view of ongoing research, changes in government regulations, and the constant flow of information relating to drug therapy and drug reactions, the reader is urged to check the package insert for each drug for any changes in indications and dosage and for added warnings and precautions. This is particularly important when the recommended agent is a new and/or infrequently employed drug. Disclaimer: The statements, opinions and data contained in this publication are solely those of the individual authors and contributors and not of the publishers and the editor(s). The appearance of advertisements or/and product references in the publication is not a warranty, endorsement, or approval of the products or services advertised or of their effectiveness, quality or safety. The publisher and the editor(s) disclaim responsibility for any injury to persons or property resulting from any ideas, methods, instructions or products referred to in the content or advertisements.

          History
          Page count
          Figures: 7, References: 9, Pages: 6
          Categories
          Review Article

          Oncology & Radiotherapy,Gastroenterology & Hepatology,Surgery,Nutrition & Dietetics,Internal medicine
          Robotic surgery,Senhance® robotic system,Minimally invasive surgery

          Comments

          Comment on this article