      A highly efficient bead extraction technique with low bead number for digital microfluidic immunoassay

      Read this article at

      ScienceOpenPublisherPMC
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          <p class="first" id="d8752196e263">Here, we describe a technique to manipulate a low number of beads to achieve high washing efficiency with zero bead loss in the washing process of a digital microfluidic (DMF) immunoassay. Previously, two magnetic bead extraction methods were reported in the DMF platform: (1) single-side electrowetting method and (2) double-side electrowetting method. The first approach could provide high washing efficiency, but it required a large number of beads. The second approach could reduce the required number of beads, but it was inefficient where multiple washes were required. More importantly, bead loss during the washing process was unavoidable in both methods. Here, an improved double-side electrowetting method is proposed for bead extraction by utilizing a series of unequal electrodes. It is shown that, with proper electrode size ratio, only one wash step is required to achieve 98% washing rate without any bead loss at bead number less than 100 in a droplet. It allows using only about 25 magnetic beads in DMF immunoassay to increase the number of captured analytes on each bead effectively. In our human soluble tumor necrosis factor receptor I (sTNF-RI) model immunoassay, the experimental results show that, comparing to our previous results without using the proposed bead extraction technique, the immunoassay with low bead number significantly enhances the fluorescence signal to provide a better limit of detection (3.14 pg/ml) with smaller reagent volumes (200 nl) and shorter analysis time (&lt;1 h). This improved bead extraction technique not only can be used in the DMF immunoassay but also has great potential to be used in any other bead-based DMF systems for different applications. </p>

          Related collections

          Most cited references42

          • Record: found
          • Abstract: not found
          • Article: not found

          The Effect of Droplet Size on Surface Tension

            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Digital microfluidics.

            Digital microfluidics (DMF) is an emerging liquid-handling technology that enables individual control over droplets on an open array of electrodes. These picoliter- to microliter-sized droplets, each serving as an isolated vessel for chemical processes, can be made to move, merge, split, and dispense from reservoirs. Because of its unique advantages, including simple instrumentation, flexible device geometry, and easy coupling with other technologies, DMF is being applied to a wide range of fields. In this review, we summarize the state of the art of DMF technology from the perspective of analytical chemistry in sections describing the theory of droplet actuation, device fabrication and integration, and applications.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Development of a digital microfluidic platform for point of care testing.

              Point of care testing is playing an increasingly important role in improving the clinical outcome in health care management. The salient features of a point of care device are rapid results, integrated sample preparation and processing, small sample volumes, portability, multifunctionality and low cost. In this paper, we demonstrate some of these salient features utilizing an electrowetting-based Digital Microfluidic platform. We demonstrate the performance of magnetic bead-based immunoassays (cardiac troponin I) on a digital microfluidic cartridge in less than 8 minutes using whole blood samples. Using the same microfluidic cartridge, a 40-cycle real-time polymerase chain reaction was performed within 12 minutes by shuttling a droplet between two thermal zones. We further demonstrate, on the same cartridge, the capability to perform sample preparation for bacterial infectious disease pathogen, methicillin-resistant Staphylococcus aureus and for human genomic DNA using magnetic beads. In addition to rapid results and integrated sample preparation, electrowetting-based digital microfluidic instruments are highly portable because fluid pumping is performed electronically. All the digital microfluidic chips presented here were fabricated on printed circuit boards utilizing mass production techniques that keep the cost of the chip low. Due to the modularity and scalability afforded by digital microfluidics, multifunctional testing capability, such as combinations within and between immunoassays, DNA amplification, and enzymatic assays, can be brought to the point of care at a relatively low cost because a single chip can be configured in software for different assays required along the path of care.
                Bookmark

                Author and article information

                Journal
                Biomicrofluidics
                Biomicrofluidics
                AIP Publishing
                1932-1058
                January 2016
                January 2016
                : 10
                : 1
                : 011901
                Affiliations
                [1 ]Department of Mechanical Engineering, National Chiao Tung University, Hsinchu, Taiwan
                [2 ]Department of Applied Chemistry, National Chiao Tung University, Hsinchu, Taiwan
                [3 ]Department of Obstetrics and Gynecology, Chang Gung Memorial Hospital, Tao-Yuan, Taiwan
                [4 ]Department of Obstetrics and Gynecology, Chang Gung University College of Medicine, Tao-Yuan, Taiwan
                [5 ]Department of Mechanical Engineering, National Taiwan University, Taipei, Taiwan
                [6 ]Institute of Nanoengineering and Microsystem, National Tsing Hua University, Hsinchu, Taiwan
                [7 ]Department of Power Mechanical Engineering, National Tsing Hua University, Hsinchu, Taiwan
                Article
                10.1063/1.4939942
                4714987
                26858807
                bee00278-e9a2-400b-9466-5f16ae654a4f
                © 2016
                History

                Comments

                Comment on this article