      Wearable Sweat Rate Sensors for Human Thermal Comfort Monitoring

      research-article
      1 , 2 , 1 , 1 ,
      Scientific Reports
      Nature Publishing Group UK

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          We propose watch-type sweat rate sensors capable of automatic natural ventilation by integrating miniaturized thermo-pneumatic actuators, and experimentally verify their performances and applicability. Previous sensors using natural ventilation require manual ventilation process or high-power bulky thermo-pneumatic actuators to lift sweat rate detection chambers above skin for continuous measurement. The proposed watch-type sweat rate sensors reduce operation power by minimizing expansion fluid volume to 0.4 ml through heat circuit modeling. The proposed sensors reduce operation power to 12.8% and weight to 47.6% compared to previous portable sensors, operating for 4 hours at 6 V batteries. Human experiment for thermal comfort monitoring is performed by using the proposed sensors having sensitivity of 0.039 (pF/s)/(g/m 2h) and linearity of 97.9% in human sweat rate range. Average sweat rate difference for each thermal status measured in three subjects shows (32.06 ± 27.19) g/m 2h in thermal statuses including ‘comfortable’, ‘slightly warm’, ‘warm’, and ‘hot’. The proposed sensors thereby can discriminate and compare four stages of thermal status. Sweat rate measurement error of the proposed sensors is less than 10% under air velocity of 1.5 m/s corresponding to human walking speed. The proposed sensors are applicable for wearable and portable use, having potentials for daily thermal comfort monitoring applications.

          Related collections

          Most cited references42

          • Record: found
          • Abstract: found
          • Article: not found

          Skin blood flow in adult human thermoregulation: how it works, when it does not, and why.

          The thermoregulatory control of human skin blood flow is vital to the maintenance of normal body temperatures during challenges to thermal homeostasis. Sympathetic neural control of skin blood flow includes the noradrenergic vasoconstrictor system and a sympathetic active vasodilator system, the latter of which is responsible for 80% to 90% of the substantial cutaneous vasodilation that occurs with whole body heat stress. With body heating, the magnitude of skin vasodilation is striking: skin blood flow can reach 6 to 8 L/min during hyperthermia. Cutaneous sympathetic vasoconstrictor and vasodilator systems also participate in baroreflex control of blood pressure; this is particularly important during heat stress, when such a large percentage of cardiac output is directed to the skin. Local thermal control of cutaneous blood vessels also contributes importantly--local warming of the skin can cause maximal vasodilation in healthy humans and includes roles for both local sensory nerves and nitric oxide. Local cooling of the skin can decrease skin blood flow to minimal levels. During menopause, changes in reproductive hormone levels substantially alter thermoregulatory control of skin blood flow. This altered control might contribute to the occurrence of hot flashes. In type 2 diabetes mellitus, the ability of skin blood vessels to dilate is impaired. This impaired vasodilation likely contributes to the increased risk of heat illness in this patient population during exposure to elevated ambient temperatures. Raynaud phenomenon and erythromelalgia represent cutaneous microvascular disorders whose pathophysiology appears to relate to disorders of local and/or reflex thermoregulatory control of the skin circulation.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Muscle contributions to support and progression over a range of walking speeds.

            Muscles actuate walking by providing vertical support and forward progression of the mass center. To quantify muscle contributions to vertical support and forward progression (i.e., vertical and fore-aft accelerations of the mass center) over a range of walking speeds, three-dimensional muscle-actuated simulations of gait were generated and analyzed for eight subjects walking overground at very slow, slow, free, and fast speeds. We found that gluteus maximus, gluteus medius, vasti, hamstrings, gastrocnemius, and soleus were the primary contributors to support and progression at all speeds. With the exception of gluteus medius, contributions from these muscles generally increased with walking speed. During very slow and slow walking speeds, vertical support in early stance was primarily provided by a straighter limb, such that skeletal alignment, rather than muscles, provided resistance to gravity. When walking speed increased from slow to free, contributions to support from vasti and soleus increased dramatically. Greater stance-phase knee flexion during free and fast walking speeds caused increased vasti force, which provided support but also slowed progression, while contralateral soleus simultaneously provided increased propulsion. This study provides reference data for muscle contributions to support and progression over a wide range of walking speeds and highlights the importance of walking speed when evaluating muscle function.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              A short history of sweat gland biology.

              The axilla, especially its microflora and axillary sweat glands as well as their secretions, is the main target of cosmetic compositions such as deodorants or antiperspirants. There are three types of sweat glands present in the axillary skin, namely apocrine, eccrine and apoeccrine sweat glands. Here, we provide an overview of the morphological, structural and functional characteristics of the different gland types and present techniques that allow their clear distinction. Moreover, we describe different forms of perspiration as physical reactions to external and internal stimuli.
                Bookmark

                Author and article information

                Contributors
                nanosys@kaist.ac.kr
                Journal
                Sci Rep
                Sci Rep
                Scientific Reports
                Nature Publishing Group UK (London )
                2045-2322
                19 January 2018
                19 January 2018
                2018
                : 8
                : 1181
                Affiliations
                [1 ]ISNI 0000 0001 2292 0500, GRID grid.37172.30, Department of Bio and Brain Engineering, , Korea Advanced Institute of Science and Technology (KAIST), ; 271 Daehak-ro, Yuseong-gu, Daejeon 34141 Republic of Korea
                [2 ]ISNI 0000 0001 2301 0664, GRID grid.410883.6, Present Address: Center for Medical Convergence Metrology, , Korea Research Institute of Standards and Science (KRISS), ; 267 Gajeong-ro, Yuseong-gu, Daejeon 34113 Republic of Korea
                Article
                19239
                10.1038/s41598-018-19239-8
                5775419
                29352237
                bfd3a5c4-36f1-461c-8c62-387b2b59def0
                © The Author(s) 2018

                Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/.

                History
                : 4 September 2017
                : 14 December 2017
                Categories
                Article
                Custom metadata
                © The Author(s) 2018

                Uncategorized
                Uncategorized

                Comments

                Comment on this article