5
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: found
      Is Open Access

      Mixed-Reality-Assisted Puncture of the Common Femoral Artery in a Phantom Model

      , , , , ,
      Journal of Imaging
      MDPI AG

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Percutaneous femoral arterial access is daily practice in a variety of medical specialties and enables physicians worldwide to perform endovascular interventions. The reported incidence of percutaneous femoral arterial access complications is 3–18% and often results from suboptimal puncture location due to insufficient visualization of the target vessel. The purpose of this proof-of-concept study was to evaluate the feasibility and the positional error of a mixed-reality (MR)-assisted puncture of the common femoral artery in a phantom model using a commercially available navigation system. In total, 15 MR-assisted punctures were performed. Cone-beam computed tomography angiography (CTA) was used following each puncture to allow quantification of positional error of needle placements in the axial and sagittal planes. Technical success was achieved in 14/15 cases (93.3%) with a median axial positional error of 1.0 mm (IQR 1.3) and a median sagittal positional error of 1.1 mm (IQR 1.6). The median duration of the registration process and needle insertion was 2 min (IQR 1.0). MR-assisted puncture of the common femoral artery is feasible with acceptable positional errors in a phantom model. Future studies should aim to measure and reduce the positional error resulting from MR registration.

          Related collections

          Most cited references38

          • Record: found
          • Abstract: found
          • Article: found
          Is Open Access

          Through the HoloLens™ looking glass: augmented reality for extremity reconstruction surgery using 3D vascular models with perforating vessels

          Precision and planning are key to reconstructive surgery. Augmented reality (AR) can bring the information within preoperative computed tomography angiography (CTA) imaging to life, allowing the surgeon to ‘see through’ the patient’s skin and appreciate the underlying anatomy without making a single incision. This work has demonstrated that AR can assist the accurate identification, dissection and execution of vascular pedunculated flaps during reconstructive surgery. Separate volumes of osseous, vascular, skin, soft tissue structures and relevant vascular perforators were delineated from preoperative CTA scans to generate three-dimensional images using two complementary segmentation software packages. These were converted to polygonal models and rendered by means of a custom application within the HoloLens™ stereo head-mounted display. Intraoperatively, the models were registered manually to their respective subjects by the operating surgeon using a combination of tracked hand gestures and voice commands; AR was used to aid navigation and accurate dissection. Identification of the subsurface location of vascular perforators through AR overlay was compared to the positions obtained by audible Doppler ultrasound. Through a preliminary HoloLens-assisted case series, the operating surgeon was able to demonstrate precise and efficient localisation of perforating vessels.
            Bookmark
            • Record: found
            • Abstract: not found
            • Article: not found

            Pedicle screw navigation using surface digitization on the Microsoft HoloLens

              Bookmark
              • Record: found
              • Abstract: found
              • Article: found
              Is Open Access

              Surgery guided by mixed reality: presentation of a proof of concept

              Surgical innovation aims to improve both patient outcome and safety. Among many others, computer-based solutions such as 3-D anatomical reconstruction and computer-based procedures planning have shown clear benefits to patients (Beckmann et al. 2009, Hernandez et al. 2017, Saragaglia et al. 2018). The next step in the usage of 3D anatomical information is to go from planning to per-operative usage. This can be done using augmented reality (AR), a technique that allows the superimposing of a digital image on top of the visual field, i.e., augmenting reality. As virtual elements in the form of holograms align with the reality this is commonly referred to as mixed reality (MR) as it enhances reality. Recently, Microsoft has developed a new concept of an MR headset (HoloLens), equipped with motors, that allows the hand user to interact with the headset by oral command or simple gesture. The promise of such technology in the surgical field is huge, as it allows the surgeon (i) to gain access to computer-based solutions in real time during the procedure while remaining totally sterile, (ii) to gain access to 3-D holograms related to the patient imaging or the surgical technique, and (iii) to remotely interact with colleagues located outside the theatre. Here, we present the first use of such a system in a surgical environment and focus on the latest trends of the rapidly developing connection between MR and surgery. Methods Patient The patient was an 80-year-old woman (height 155 cm, weight 52 kg) with advanced arthritis of the shoulder combined with rupture of the tendons covering the joint, motivating the implantation of a shoulder prosthesis. Technical setup The HoloLens headset is a self-contained, holographic computer, enabling its user to engage with her/his digital content and interact with holograms in the world around her/him. The technical characteristics of the device are depicted in the supplementary Appendix. No specific installation time in the operating room is required, the device being wireless. Data preparation The raw DICOM files are too large to be downloaded into the headset. Therefore, the DICOM data stored in the hospital PACS were instantly loaded and preprocessed in a Cloud Unit (Azure Graphic Processing Unit—Microsoft Corp, Redmond, WA, USA). During the surgery, the DICOM data are made available for the headset through a dedicated radiological holographic application (TeraRecon Holoportal—https://www.terarecon.com/) connected via WiFi to the Cloud Unit. Surgical procedure A standard reverse shoulder arthroplasty was performed. The challenge in this surgery was the limited bone stock of the vault (due to the patient’s anatomy with a Walch A2-type glenoid). Navigational technique There was no calibration between HoloLens and the navigation system, as the MR headset has a capacity to drag the holograms manually. Subsequently, the holographic 3-D reconstruction of the scapula was manually positioned in such a way that the visible part of the bone matched with the corresponding part of the hologram. The surgeon was then able to see the hidden part of the scapula in a holographic mode. Funding and potential conflicts of interest Funding source: MOVEO Foundation. Dr Mir has acted as a consultant for Amgen, BMS, Eli-Lilly, Lundbeck, MSD, Novartis, Pfizer, Roche, Servier and Vifor. Dr Gregory has acted as a consultant for Evolutis. The other authors have no conflict of interest to disclose. Results The prosthesis was implanted with the aid of this MR headset at Avicenne Hospital in Bobigny, France, on December 5, 2017. As described above, the surgeon was able to access the patient’s medical data combined with the data of the operative technique, which were transmitted into his operating headset in real time during the intervention, e.g., patient scapula 3-D reconstruction extracted from her CT scan, the planning of the positioning of the glenoid and the whole operative technique developed in 3-D holograms according to the planned position. Hence, the surgeon was able to compare, stage by stage, what he was doing with what had to be done. The surgeon was also able to drag the 3-D reconstruction of the scapula, scaled 100%, right before his eyes, by simple gestures in front of the headset (Figure 1) in approximately 3 minutes. He was then able to superimpose the CT scan scapula reconstruction with manual adjustment onto the visible part of the bone (Figure 2 and see video at https://youtu.be/oQu1rGt6ym4). Figure 1. Outside view of the headset during the surgical procedure. Figure 2. View from the headset during the surgical procedure. The surgeon also shared what he saw in his headset with 4 other surgeons in the USA and in the UK, who were able to send information in the operator’s field of vision, via Skype, throughout the intervention (which was taking place in France). This is the first time that such complete usage of the immersive and collaborative aspects has been implemented in surgery of the shoulder. The total duration of surgery was 90 minutes, similar to the mean duration of such a procedure in the operator’s experience (without the use of HoloLens). The duration of the procedure was prolonged due to the fact that it was broadcast on the Web and required dedicated time to comment on every step. On the other hand, a better understanding of the patient’s anatomy as allowed by the use of the headset probably contributed to time-saving. Postoperative CT scan showed adequate position of the prosthesis (Figure 3). The patient experienced no peri- or postoperative complication and was discharged home 3 days after surgery (similar to the routine practice in our institution). Figure 3. Postoperative CT scan of the glenoid (top left: sagittal view; bottom left: coronal view; right: axial view). Postoperative visit on day 45 confirmed the lack of postoperative complications. Discussion Compared with a classical surgical procedure, the use of an MR headset might provide an improvement in outcomes for both surgeon and patient, without reducing the safety of the procedure. Indeed, thanks to 3-D holograms, the keyframes of the operation as well as critical organs (nerves, arteries…) are shown in real time by the surgeon. This provides a gain in accuracy and safety in the procedurem which finally might result in time-saving and correct positioning of the implant (Léger et al. 2017, Vávra et al. 2017). Notably, the technical setup of the device and data preparation before surgery had short duration (as explained above) but might be time-consuming for first-time users. The improvement of the surgical procedure also lies in the opportunity for the surgeon to interact with colleagues and ask them for advice or warnings. The operation field is often small, and the surgeon’s gestures as well as an accurate view of the patient’s anatomy are restricted to only the surgeon and his assistant. Thanks to this new technology, the surgeon’s view is projected onto a screen, and accessible to many more people. This provides constant feedback on his/her decision, as well as being a potential educational tool. The safety of the patient seems not be compromised by this new device. Indeed, the operating time was not lengthened, and no major adverse events occurred. On the contrary, the security of the surgery is probably improved, because the surgeon can see the patient’s anatomy directly, and other physicians can give helpful comments. As an illustration, Opolski et al. (2017) performed revascularization of a chronic coronary total occlusion assisted by AR glasses without adverse events. This improvement does not incur a loss of comfort and focus. The weight of the device is low (579 grams, see supplementary Appendix), and the use of AR devices of comparable weight did not cause pain or tiredness (Sinkin et al. 2016, Léger et al. 2017). The amount of information is controlled in real time by the surgeon, so that the cognitive load is tolerable. The voice- and image-activated command is easy to use, without latency or excessive repetition (Léger et al. 2017). The image quality, contrast and stability are good enough not to cause tiredness or motion sickness. During the videoconferencing, no cut-offs occurred; thus, the constant of interaction and procedure safety was guaranteed. Finally, the battery has sufficient durability for most surgical procedures (up to 5.5 hours, see supplementary Appendix). When a new technology appears, patient and staff approval is also a fundamental element. Muensterer et al. (2014) reported that their colleagues, staff, families and patients had a positive response to such technology. Importantly, issues of data protection will have to be addressed for greater use of this technology (Muensterer et al. 2014, Vávra et al. 2017). AR interest in surgical procedures is strongly increasing, as shown by the large number of published studies. Reviews of the literature, randomized controlled trials, and single-center tests are multiplying (Muensterer et al. 2014, Sinkin et al. 2016, Léger et al. 2017, Opolski et al. 2017, Vávra et al. 2017, Pulijala et al. 2018). Various AR and MR devices are currently being tested, and data are convergeing toward the same results: procedure performance, and effectiveness as a learning tool. The divergence mainly involves surgeon comfort and satisfaction, and is related to the AR device itself (Table). From an educational perspective, while the use of screens in the surgical theater has exploded over the last few years, the vision of high-quality AR for surgery (Ponce et al. 2014) or medical training has not yet been realized. To date, AR-based simulation is considered a promising approach in the surgical curriculum, allowing not only technical performance evaluation, but also telementoring. Because the gap between research and wide application is mainly a question of cost, things could change rapidly in the next years thanks to cheaper AR devices. As mentioned in the ASiT position paper (Milburn et al. 2012), regional disparities in the availability of simulators and financial restraints are theoretical limitations to their wide use. We believe that recent, inexpensive devices will help lessen these expected difficulties. Importantly, dedicated teaching time should be made available within existing and future projects (Milburn et al. 2012). In summary, we believe that our case report illustrates the fact that surgical practice and education can derive significant benefits from the implementation of AR and MR tools in daily practice. We believe that such an immersive and cost-effective approach would improve the training capacity of orthopedic surgery simulations. Current published data on AR in surgery Study Outcomes Main findings Vávra et al.2017 Review of the literature: augmented reality can presently improve the results of surgical procedures?       – AR is an effective tool for training and skill assessment of surgery residents, other medical staff, or students     – The interest of surgeons is increasing     – The performance is comparable to traditional techniques     – The time required for completing a procedure has been reduced while using any form of AR     – Inattentional blindness: the surgeon does not see an unexpected object which suddenly appears in his field of view     – The amount of information is increasing and may be distracting     – The latency of the whole system is also of concern     – Long-term wear comfort is an issue     – AR projections produce simulator sickness Sinkin et al.2016 Ease of use       – Average ease of image capture =3.11/5   Quality of images       – Average ease of video capture =3.22/5   Gaze disruption       – Average ease of using the wink feature =1.89   Distraction       – Quality of image and video =3.89 and 3.67/7   Comfort and satisfaction to wear: Average for comfort =4.56/7, Average for satisfaction =3.78/7       – 33% of users felt the device to be a distraction from the case Pulijala et al. 2017 Self-assessment scores of trainee confidence before and after the intervention. Novice surgical residents       – The study group participants showed greater perceived self-confidence levels Opolski et al.2017 Operators’ satisfaction assessed by a 5-point Likert scale       – The voice-activated co-registration and review of images were feasible and highly rated by operators (4.7/5 points)     – There were no major adverse events     – More frequent selection of the first-choice stiff wire and lower contrast exposure     – Success rates and safety outcomes remained similar between the two groups Muensterer et al.2014 AR Glass was worn daily for 4 weeks to identify and evaluate daily activities with potential applicability       – Wearing Glass throughout the day was well tolerated     – Colleagues, staff, families, and patients overwhelmingly had a positive response to Glass     – Low battery endurance     – Poor overall audio quality     – Long transmission latency combined with interruptions and cut-offs during internet videoconferencing Léger et al.2017 Time taken to perform the task. Attention shifts:       – There were significant reductions in terms of the time taken to perform the task, and attention shifts   Feelings about accuracy, intuition, comfort, perceived cognitive load       – Users felt that the system was easier to use and that their performance was better
                Bookmark

                Author and article information

                Journal
                Journal of Imaging
                J. Imaging
                MDPI AG
                2313-433X
                February 2022
                February 16 2022
                : 8
                : 2
                : 47
                Article
                10.3390/jimaging8020047
                35200749
                c260191d-e137-4bb5-9cc2-3070a509767a
                © 2022

                https://creativecommons.org/licenses/by/4.0/

                History

                Comments

                Comment on this article