      Device-detected atrial tachyarrhythmias predict adverse outcome in real-world patients with implantable biventricular defibrillators.

      Journal of the American College of Cardiology
      Aged, Atrial Fibrillation, complications, diagnosis, physiopathology, Defibrillators, Implantable, Disease Progression, Electrocardiography, Ambulatory, instrumentation, Female, Follow-Up Studies, Heart Failure, etiology, therapy, Humans, Male, Prognosis, Stroke Volume, Tachycardia, Ectopic Atrial, Time Factors, Ventricular Function, Left

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          The purpose of this analysis was to evaluate the correlation between atrial tachycardia (AT) or atrial fibrillation (AF) and clinical outcomes in heart failure (HF) patients implanted with a cardiac resynchronization therapy defibrillator (CRT-D). In HF patients, AT and AF have high prevalence and are associated with compromised hemodynamic function. Forty-four Italian cardiological centers followed up 1,193 patients who received a CRT-D according to current guidelines for advanced HF, New York Heart Association functional class ≥ II, left ventricular ejection fraction ≤ 35%, and QRS complex ≥ 120 ms. All patients were in sinus rhythm at implant. During a median follow-up period of 13 months, AT/AF >10 min occurred in 361 of 1,193 (30%) patients. The composite end point (deaths or HF hospitalizations) occurred in 174 of 1,193 (14.6%). Multivariate time-dependent Cox regression analyses showed that composite end point risk was higher among patients with device-detected AT/AF (hazard ratio [HR]: 2.16, p = 0.032), New York Heart Association functional class III or IV compared with II (HR: 2.09, p = 0.002), and absence of beta-blockers (HR: 1.36, p = 0.036). Furthermore, the composite end point risk was inversely associated with left ventricular ejection fraction (HR: 1.04, p = 0.045), increasing by a factor of 4% for each 1% decrease in left ventricular ejection fraction. In HF patients with CRT-D, device-detected AT/AF is associated with a worse prognosis. Continuous device diagnostics monitoring and Web-based alerts may inform the physician of AT/AF occurrences and identify patients at risk of cardiac deterioration or patients with suboptimal rate or rhythm control. (Italian ClinicalService Project; NCT01007474). Copyright © 2011 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

          Related collections

          Author and article information

          Comments

          Comment on this article