      Targeted delivery of doxorubicin to the rat brain at therapeutic levels using MRI-guided focused ultrasound.

      International Journal of Cancer. Journal International du Cancer
      Animals, Brain, drug effects, Doxorubicin, administration & dosage, Drug Delivery Systems, Magnetic Resonance Imaging, Male, Rats, Rats, Sprague-Dawley, Ultrasonography, methods

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          The clinical application of chemotherapy to brain tumors has been severely limited because antitumor agents are typically unable to penetrate an intact blood-brain barrier (BBB). Although doxorubicin (DOX) has been named as a strong candidate for chemotherapy of the central nervous system (CNS), the BBB often prevents cytotoxic levels from being achieved. In this study, we demonstrate a noninvasive method for the targeted delivery of DOX through the BBB, such that drug levels shown to be therapeutic in human tumors are achieved in the normal rat brain. Using MRI-guided focused ultrasound with preformed microbubbles (Optison) to locally disrupt the BBB and systemic administration of DOX, we achieved DOX concentrations of 886 +/- 327 ng/g tissue in the brain with minimal tissue effects. Tissue DOX concentrations of up to 5,366 +/- 659 ng/g tissue were achieved with higher Optison doses, but with more significant tissue damage. In contrast, DOX accumulation in nontargeted contralateral brain tissue remained significantly lower for all paired samples (p < 0.001). These results suggest that targeted delivery by focused ultrasound may render DOX chemotherapy a viable treatment option against CNS tumors, despite previous accessibility limitations. In addition, MRI signal enhancement in the sonicated region correlated strongly with tissue DOX concentration (r = 0.87), suggesting that contrast-enhanced MRI could perhaps indicate drug penetration during image-guided interventions. Our technique using MRI-guided focused ultrasound to achieve therapeutic levels of DOX in the brain offers a large step forward in the use of chemotherapy to treat patients with CNS malignancies.

          Related collections

          Author and article information

          Comments

          Comment on this article