1
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: found
      Is Open Access

      First Characterization of Novel Silicon Carbide Detectors with Ultra-High Dose Rate Electron Beams for FLASH Radiotherapy

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Ultra-high dose rate (UHDR) beams for FLASH radiotherapy present significant dosimetric challenges. Although novel approaches for decreasing or correcting ion recombination in ionization chambers are being proposed, applicability of ionimetric dosimetry to UHDR beams is still under investigation. Solid-state sensors have been recently investigated as a valuable alternative for real-time measurements, especially for relative dosimetry and beam monitoring. Among them, Silicon Carbide (SiC) represents a very promising candidate, compromising between the maturity of Silicon and the robustness of diamond. Its features allow for large area sensors and high electric fields, required to avoid ion recombination in UHDR beams. In this study, we present simulations and experimental measurements with the low energy UHDR electron beams accelerated with the ElectronFLASH machine developed by the SIT Sordina company (IT). The response of a newly developed 1 × 1 cm2 SiC sensor in charge as a function of the dose-per-pulse and its radiation hardness up to a total delivered dose of 90 kGy, was investigated during a dedicated experimental campaign, which is, to our knowledge, the first characterization ever done of SiC with UHDR-pulsed beams accelerated by a dedicated ElectronFLASH LINAC. Results are encouraging and show a linear response of the SiC detector up to 2 Gy/pulse and a variation in the charge per pulse measured for a cumulative delivered dose of 90 kGy, within ±0.75%.

          Related collections

          Most cited references28

          • Record: found
          • Abstract: not found
          • Article: not found

          Geant4—a simulation toolkit

            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Ultrahigh dose-rate FLASH irradiation increases the differential response between normal and tumor tissue in mice.

            In vitro studies suggested that sub-millisecond pulses of radiation elicit less genomic instability than continuous, protracted irradiation at the same total dose. To determine the potential of ultrahigh dose-rate irradiation in radiotherapy, we investigated lung fibrogenesis in C57BL/6J mice exposed either to short pulses (≤ 500 ms) of radiation delivered at ultrahigh dose rate (≥ 40 Gy/s, FLASH) or to conventional dose-rate irradiation (≤ 0.03 Gy/s, CONV) in single doses. The growth of human HBCx-12A and HEp-2 tumor xenografts in nude mice and syngeneic TC-1 Luc(+) orthotopic lung tumors in C57BL/6J mice was monitored under similar radiation conditions. CONV (15 Gy) triggered lung fibrosis associated with activation of the TGF-β (transforming growth factor-β) cascade, whereas no complications developed after doses of FLASH below 20 Gy for more than 36 weeks after irradiation. FLASH irradiation also spared normal smooth muscle and epithelial cells from acute radiation-induced apoptosis, which could be reinduced by administration of systemic TNF-α (tumor necrosis factor-α) before irradiation. In contrast, FLASH was as efficient as CONV in the repression of tumor growth. Together, these results suggest that FLASH radiotherapy might allow complete eradication of lung tumors and reduce the occurrence and severity of early and late complications affecting normal tissue.
              Bookmark
              • Record: found
              • Abstract: not found
              • Article: not found

              Geant4 developments and applications

                Bookmark

                Author and article information

                Contributors
                (View ORCID Profile)
                (View ORCID Profile)
                (View ORCID Profile)
                (View ORCID Profile)
                (View ORCID Profile)
                (View ORCID Profile)
                Journal
                ASPCC7
                Applied Sciences
                Applied Sciences
                MDPI AG
                2076-3417
                March 2023
                February 25 2023
                : 13
                : 5
                : 2986
                Article
                10.3390/app13052986
                c755c2f3-34fe-4b19-8bc4-3e93d2959d5d
                © 2023

                https://creativecommons.org/licenses/by/4.0/

                History

                Comments

                Comment on this article