          Abstract

          Background

          Nasotracheal intubation (NTI) is frequently performed for oral and maxillofacial surgeries. This study evaluated whether NTI is easier when guided by Disposcope endoscopy or fibreoptic bronchoscopy.

          Methods

          Sixty patients (30 per group) requiring NTI were randomly assigned to undergo fibreoptic bronchoscopy-guided (fibreoptic group) or Disposcope endoscope-guided (Disposcope group) NTI. The NTI time, which was defined as the time from when the fibreoptic bronchoscope or aseptic suction catheter was inserted into the nasal cavity to the time at which the tracheal tube was correctly inserted through the glottis, was recorded. Epistaxis was evaluated by direct laryngoscopy five minutes after completing NTI and was scored as one of four grades according to the following modified criteria: no epistaxis, mild epistaxis, moderate epistaxis, and severe epistaxis.

          Results

          The time to complete NTI was significantly longer in the fibreoptic group than in the Disposcope group (38.4 s vs 24.1 s; mean difference, 14.2 s; 95% confidence interval (CI), 10.4 to 18.1). Mild epistaxis was observed in 8 patients in the fibreoptic group and in 7 patients in the Disposcope group (26.7% vs 23.3%, respectively; relative risk, 1.2; 95% CI, 0.4 to 3.9), though no moderate or severe epistaxis occurred in either group. Furthermore, no obvious nasal pain was reported by any of the patients at any time point after extubation ( P = 0.74).

          Conclusion

          NTI can be completed successfully using either fibreoptic bronchoscopy or Disposcope endoscope as a guide without any severe complications. However, compared to fibreoptic bronchoscopy, Disposcope endoscope requires less execution time (the NTI time).

          Trial registration

          This clinical research was registered at the Chinese Clinical Trial Registry ( www.chictr.org.cn, ChiCTR-IPR-17011462, date of registration, May 2017).

          Related collections

          Most cited references17

          • Record: found
          • Abstract: found
          • Article: not found

          Nasotracheal intubation under curve-tipped suction catheter guidance reduces epistaxis.

          Nasotracheal intubation (NTI) has greater potential for trauma of nasopharyngeal mucosa than orotracheal intubation. The present study investigated the success rate of NTI and frequency of nasal bleeding using a curve-tipped suction catheter (CTSC) to guide nasotracheal tube advancement. Subjects comprised 131 adult patients who under-went NTI. Subjects were randomly divided into two groups: a) NTI under CTSC guidance (G[+] group). The CTSC (14 Fr) was first inserted through the tracheal tube, with the tip of the CTSC emerging from the distal end of the tube. The curved tip was directed ventrally. Both tracheal tube and CTSC were advanced together through the nasopharynx; b) NTI without CTSC guidance (G[-] group). The tracheal tube was advanced into the nasal cavity and passed into the pharynx without CTSC guidance. The time required to pass the endotracheal tube through the nasal cavity (nasal passage time), success rate of nasal passage with nasotracheal tube, and the incidence and severity of nasal bleeding were compared. Success rate for nasal passage was 100% in the G(+) group (62/62) and 82.6% in the G(-) group (57/69; P = 0.0006). Frequency of nasal bleeding was significantly lower in the G(+) group (21/62, 33.9%) than in the G(-) group (37/69, 53.6%; P = 0.023). Severity of nasal bleeding was also significantly lower in the G(+) group than in the G(-) group (P = 0.030). Nasotracheal intubation under CTSC guidance increases the success rate of airway instrumentation, and also reduces the incidence and severity of epistaxis.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: found
            Is Open Access

            The usefulness of the McGrath MAC laryngoscope in comparison with Airwayscope and Macintosh laryngoscope during routine nasotracheal intubation: a randomaized controlled trial

            Background McGrath MAC video laryngoscope offers excellent laryngosopic views and increases the success rate of orotracheal intubation in some cases. The aim of this study was to determine the usefulness of McGrath MAC for routine nasotracheal intubation by comparing McGrath MAC with Airway scope and Macintosh laryngoscope. Methods A total of 60 adult patients with ASA physical status class 1 or 2, aged 20–70 years were enrolled in this study. Patients were scheduled for elective oral surgery under general anesthesia with nasotracheal intubation. Exclusion criteria included lack of consent and expected difficult airway. Patients were randomly allocated to three groups: McGrath MAC (n = 20), Airway scope (n = 20), and Macintosh laryngoscope (n = 20). After induction, nasotracheal intubation was performed by six expert anesthesiologists with more than 6 years of experience. Results There were no significant differences in preoperative airway assessment among the three groups. Successful tracheal intubation time was 26.8 ± 5.7 (mean ± standard deviation) s for McGrath MAC, 36.4 ± 11.0 s for Airway scope, and 36.5 ± 8.9 s for Macintosh laryngoscope groups. The time for successful tracheal intubation for McGrath MAC group was significantly shorter than that for Airway scope and Macintosh laryngoscope (p < 0.01). McGrath MAC significantly improved the Cormack Lehane grade for nasotracheal intubation compared with Macintosh laryngoscope (p < 0.05). Conclusion McGrath MAC significantly facilitates routine nasotracheal intubation compared with Airwayscope and Macintosh laryngoscope by shortening the tracheal intubation time and improving the Cormack Lehane grade. Trial registration UMINCTR Registration number UMIN000023506. Registered 5 Aug 2016.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Epistaxis during nasotracheal intubation: a comparison of nostril sides.

              It is commonly believed that for preventing epistaxis during nasotracheal intubation (NTI), the right nostril should be used. However, there is no real evidence as to which nostril should be used. In this study, we tested our hypothesis that epistaxis during NTI is more frequent and severe using the left nostril rather than the right, provided that patency appears equal on both sides of the nose.
                Bookmark

                Author and article information

                Contributors
                +8655162183386 , majuny163@163.com
                Journal
                BMC Anesthesiol
                BMC Anesthesiol
                BMC Anesthesiology
                BioMed Central (London )
                1471-2253
                23 August 2019
                23 August 2019
                2019
                : 19
                : 163
                Affiliations
                [1 ]ISNI 0000000121679639, GRID grid.59053.3a, Hefei National Laboratory for Physical Sciences at the Microscale, Department of Biophysics and Neurobiology, , University of Science and Technology of China, ; Hefei, 230027 People’s Republic of China
                [2 ]Department of Anesthesiology, The First People’s Hospital of Hefei, Anhui Medical University, Hefei, Anhui 230061 People’s Republic of China
                Author information
                http://orcid.org/0000-0003-4053-5942
                Article
                834
                10.1186/s12871-019-0834-3
                6706907
                31438861
                cb55d828-90e3-43f6-81ce-3e3f4dcd5fd5
                © The Author(s). 2019

                Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License ( http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver ( http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.

                History
                : 7 June 2019
                : 18 August 2019
                Categories
                Research Article
                Custom metadata
                © The Author(s) 2019

                Anesthesiology & Pain management
                disposcope endoscope,nasotracheal intubation,fibreoptic,video stylet,endotracheal tube

                Comments

                Comment on this article