          Abstract

          During the past few years, transesophageal echocardiography (TEE) has been increasingly used in clinical cardiology; data concerning the practicability and safety of the technique, however, are rare. This report analyzes the experience of 15 European centers performing TEE studies for at least 1 year. At the time of this survey, 10,419 TEE examinations had been attempted or performed in these institutions. These TEE examinations were carried out by 54 physicians, 53.7% of whom had been trained in endoscopic techniques. Within the same time period, 160,431 precordial echocardiographic examinations were performed in the 15 institutions; the ratio between TEE and transthoracic studies averaged 9.03 +/- 6.4% (range of the 15 centers, 1.4-23.6%). Of the 10,419 patients, 9,240 (88.7%) were conscious inpatients or outpatients at the time of the TEE examination; the vast majority of the conscious patients did not receive intravenous sedation before TEE. In 201 cases (1.9%), insertion of the TEE probe was unsuccessfully attempted because of a lack of patient cooperation and/or operator experience (98.5%) or because of anatomical reasons (1.5%). In 90 of 10,218 TEE studies (0.88%) with successful probe insertion, the examination had to be interrupted because of the patient's intolerance of the echoscope (65 cases); because of pulmonary (eight cases), cardiac (eight cases), or bleeding complications (two cases); or for other reasons (seven cases). One of the bleeding complications resulted from a malignant lung tumor with esophageal infiltration and was fatal (mortality rate, 0.0098%). This multicenter survey documents that TEE studies are associated with an acceptable low risk when used by experienced operators under proper safety conditions.

          Related collections

          Author and article information

          Journal
          1999032
          10.1161/01.CIR.83.3.817

          Chemistry
          Data Collection,Echocardiography,adverse effects,methods,Esophagus,Europe,Hospitals,Humans,Patient Acceptance of Health Care,Risk Factors,Safety

          Comments

          Comment on this article