5
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: found
      Is Open Access

      Template Free Anisotropically Grown Gold Nanocluster Based Electrochemical Immunosensor for Ultralow Detection of Cardiac Troponin I

      , , , , ,
      Biosensors
      MDPI AG

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Anisotropic gold nanostructures have fascinated with their exceptional electronic properties, henceforth exploited for the fabrication of electrochemical sensors. However, their synthesis approaches are tedious and often require a growth template. Modern lifestyle has caused an upsurge in the risk of heart attack and requires urgent medical attention. Cardiac troponin I can serve as a biomarker in identification of suspected myocardial infection (heart attack). Hence the present work demonstrates the fabrication of a sensing platform developed by assimilating anisotropic gold nanoclusters (AuNCs) with anti cTnI antibody (acTnI) for the detection of cardiac troponin I (cTnI). The uniqueness and ease of synthesis by a template-free approach provides an extra edge for the fabrication of AuNC coated electrodes. The template-free growth of anisotropic AuNCs onto the indium tin oxide (ITO) glass substrates offers high sensitivity (2.2 × 10−4 A ng−1 mL cm−2) to the developed sensor. The immunosensor was validated by spiking different concentrations of cTnI in artificial serum with negligible interference under optimized conditions. The sensor shows a wide range of detection from 0.06–100 ng/mL with an ultralow detection limit. Thus, it suggests that the template-free immunosensor can potentially be used to screen the traces of cTnI present in blood serum samples, and the AuNCs based platform holds great promise as a transduction matrix, hence it can be exploited for broader sensing applications.

          Related collections

          Most cited references36

          • Record: found
          • Abstract: not found
          • Article: not found

          Heart disease and stroke statistics--2014 update: a report from the American Heart Association.

            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Cardiac-specific troponin I levels to predict the risk of mortality in patients with acute coronary syndromes.

            In patients with acute coronary syndromes, it is desirable to identify a sensitive serum marker that is closely related to the degree of myocardial damage, provides prognostic information, and can be measured rapidly. We studied the prognostic value of cardiac troponin I levels in patients with unstable angina or non-Q-wave myocardial infarction. In a multicenter study, blood specimens from 1404 symptomatic patients were analyzed for cardiac troponin I, a serum marker not detected in the blood of healthy persons. The relation between mortality at 42 days and the level of cardiac troponin I in the specimen obtained on enrollment was determined both before and after adjustment for baseline characteristics. The mortality rate at 42 days was significantly higher in the 573 patients with cardiac troponin I levels of at least 0.4 ng per milliliter (21 deaths, or 3.7 percent) than in the 831 patients with cardiac troponin I levels below 0.4 ng per milliliter (8 deaths, or 1.0 percent; P or = 65 years). In patients with acute coronary syndromes, cardiac troponin I levels provide useful prognostic information and permit the early identification of patients with an increased risk of death.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Nanomaterial-based biosensors for detection of pathogenic virus

              Viruses are real menace to human safety that cause devastating viral disease. The high prevalence of these diseases is due to improper detecting tools. Therefore, there is a remarkable demand to identify viruses in a fast, selective and accurate way. Several biosensors have been designed and commercialized for detection of pathogenic viruses. However, they present many challenges. Nanotechnology overcomes these challenges and performs direct detection of molecular targets in real time. In this overview, studies concerning nanotechnology-based biosensors for pathogenic virus detection have been summarized, paying special attention to biosensors based on graphene oxide, silica, carbon nanotubes, gold, silver, zinc oxide and magnetic nanoparticles, which could pave the way to detect viral diseases and provide healthy life for infected patients.
                Bookmark

                Author and article information

                Contributors
                Journal
                BIOSHU
                Biosensors
                Biosensors
                MDPI AG
                2079-6374
                December 2022
                December 07 2022
                : 12
                : 12
                : 1144
                Article
                10.3390/bios12121144
                cf0d928d-9685-4e84-ae77-634a488106cc
                © 2022

                https://creativecommons.org/licenses/by/4.0/

                History

                Comments

                Comment on this article