      Diagnosis of heart failure using urinary natriuretic peptides.

      Clinical Science (London, England : 1979)
      Aged, Aged, 80 and over, Area Under Curve, Atrial Natriuretic Factor, blood, urine, Biological Markers, Case-Control Studies, Female, Heart Failure, diagnosis, Humans, Male, Natriuretic Peptide, Brain, Natriuretic Peptide, C-Type, Nerve Tissue Proteins, Peptide Fragments, Predictive Value of Tests, Protein Precursors, Sensitivity and Specificity

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          In the present study, we assessed the use of urinary natriuretic peptides [N-terminal proatrial natriuretic peptide (N-ANP) and N-terminal pro-brain natriuretic peptide (N-BNP) and C-type natriuretic peptide (CNP)] in the diagnosis of heart failure. Thirty-four consecutive hospitalized heart failure patients (median age, 75.5 years; 14 female) were compared with 82 age- and gender-matched echocardiographically normal controls. All subjects provided plasma and urine specimens. Plasma was assayed for N-BNP, and urine was assayed for N-ANP, N-BNP and CNP. The diagnostic efficiency of peptides was assessed using receiver operating characteristic (ROC) curve analysis. All three urinary natriuretic peptides were significantly elevated in heart failure patients ( P <0.001). Urine N-BNP was correlated with plasma N-BNP ( r (s)=0.53, P <0.0005). Areas under the ROC curves for urinary N-ANP, N-BNP and CNP were 0.86, 0.93 and 0.70 and for plasma N-BNP was 0.96. Correcting urinary peptide levels using urine creatinine produced ROC areas of 0.89, 0.93 and 0.76 respectively. A urine N-BNP level cut-off point of 11.6 fmol/ml had a sensitivity and specificity for heart failure detection of 97% and 78% respectively, with positive and negative predictive values of 64.7 and 98%. In conclusion, although all three natriuretic peptides were elevated in urine in heart failure, urinary N-BNP had diagnostic accuracy comparable with plasma N-BNP. Use of urinary N-BNP for heart failure diagnosis may be suitable for high-throughput screening, especially in subjects reluctant to provide blood samples.

          Related collections

          Author and article information

          Comments

          Comment on this article