31
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: not found

      Preoperative T and N staging of colorectal cancer: accuracy of contrast-enhanced multi-detector row CT colonography--initial experience.

      Radiology
      Adult, Aged, Aged, 80 and over, Colonography, Computed Tomographic, Colorectal Neoplasms, pathology, radiography, surgery, Contrast Media, Digestive System Surgical Procedures, Female, Humans, Liver Neoplasms, diagnosis, secondary, Male, Middle Aged, Neoplasm Staging, Observer Variation, Predictive Value of Tests, Preoperative Care, Prospective Studies, Radiographic Image Interpretation, Computer-Assisted, Sensitivity and Specificity

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          To evaluate the accuracy of contrast material-enhanced multi-detector row computed tomographic (CT) colonography for preoperative staging of colorectal cancer. Forty-one patients with colorectal carcinoma underwent preoperative contrast-enhanced multi-detector row CT colonography. Images were obtained in the arterial (start delay of 35 seconds) and portal venous (start delay of 70 seconds) phases. The arterial phase was focused on the suspected region of neoplasm, whereas the venous phase included the whole abdomen and pelvis. Two radiologists independently evaluated the depth of tumor invasion into the colorectal wall (T) and regional lymph node involvement (N) on transverse CT images alone and in combination with multiplanar reformations (MPRs). Disagreements were resolved by means of consensus. CT findings were compared with pathologic results, which served as the reference standard. Sensitivity, specificity, accuracy, positive predictive value, and negative predictive value were assessed. Differences in accuracy for T and N staging were assessed by using the McNemar test. In T staging, overall accuracy was 73% when transverse images were evaluated alone and 83% when they were evaluated in combination with MPRs. This difference was not significant. N staging was associated with an overall accuracy of 59% with transverse images alone and 80% with combined transverse and MPR images (P <.01). Contrast-enhanced multi-detector row CT colonography is an accurate technique for preoperative local staging of colorectal tumors. Copyright RSNA, 2004

          Related collections

          Author and article information

          Comments

          Comment on this article