3
views
0
recommends
+1 Recommend
2 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: not found

      Persistent Value of the Stethoscope in the Age of COVID-19

      review-article

      Read this article at

      ScienceOpenPublisherPMC
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          The stethoscope has long been at the center of patient care as well as a symbol of the physician-patient relationship. While advancements in other diagnostic modalities have allowed for more efficient and accurate diagnosis, the stethoscope has evolved in parallel to address the needs of the modern era of medicine. These advancements include sound visualization, ambient noise reduction/cancellation, Bluetooth™ transmission, and computer algorithm diagnostic support. However, despite these advancements, the ever-changing climate of infection prevention, especially in the wake of the COVID-19 pandemic, has led many to question the stethoscope as a vector for infectious diseases. Stethoscopes have been reported to harbor bacteria with contamination levels comparable to a physician's hand. Although disinfection is recommended, stethoscope hygiene compliance remains low. In addition, disinfectants may not be completely effective in eliminating microorganisms. Despite these risks, the growing technological integration with the stethoscope continues to make it a highly valuable tool. Rather than casting our valuable tool and symbol of medicine aside, we must create and implement an effective method of stethoscope hygiene to keep patients safe.

          • Stethoscopes are clinically valuable and integral to the doctor-patient connection

          • Technological advancement will augment the utility of the stethoscope

          • The stethoscope has high utility for assessment of COVID-19 patients

          • Pathogen contamination in light of COVID-19 is a concern for the stethoscope

          • Innovations in stethoscope hygiene will allow safe auscultation

          Related collections

          Most cited references39

          • Record: found
          • Abstract: found
          • Article: not found

          Aerosol and Surface Stability of SARS-CoV-2 as Compared with SARS-CoV-1

          To the Editor: A novel human coronavirus that is now named severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) (formerly called HCoV-19) emerged in Wuhan, China, in late 2019 and is now causing a pandemic. 1 We analyzed the aerosol and surface stability of SARS-CoV-2 and compared it with SARS-CoV-1, the most closely related human coronavirus. 2 We evaluated the stability of SARS-CoV-2 and SARS-CoV-1 in aerosols and on various surfaces and estimated their decay rates using a Bayesian regression model (see the Methods section in the Supplementary Appendix, available with the full text of this letter at NEJM.org). SARS-CoV-2 nCoV-WA1-2020 (MN985325.1) and SARS-CoV-1 Tor2 (AY274119.3) were the strains used. Aerosols (<5 μm) containing SARS-CoV-2 (105.25 50% tissue-culture infectious dose [TCID50] per milliliter) or SARS-CoV-1 (106.75-7.00 TCID50 per milliliter) were generated with the use of a three-jet Collison nebulizer and fed into a Goldberg drum to create an aerosolized environment. The inoculum resulted in cycle-threshold values between 20 and 22, similar to those observed in samples obtained from the upper and lower respiratory tract in humans. Our data consisted of 10 experimental conditions involving two viruses (SARS-CoV-2 and SARS-CoV-1) in five environmental conditions (aerosols, plastic, stainless steel, copper, and cardboard). All experimental measurements are reported as means across three replicates. SARS-CoV-2 remained viable in aerosols throughout the duration of our experiment (3 hours), with a reduction in infectious titer from 103.5 to 102.7 TCID50 per liter of air. This reduction was similar to that observed with SARS-CoV-1, from 104.3 to 103.5 TCID50 per milliliter (Figure 1A). SARS-CoV-2 was more stable on plastic and stainless steel than on copper and cardboard, and viable virus was detected up to 72 hours after application to these surfaces (Figure 1A), although the virus titer was greatly reduced (from 103.7 to 100.6 TCID50 per milliliter of medium after 72 hours on plastic and from 103.7 to 100.6 TCID50 per milliliter after 48 hours on stainless steel). The stability kinetics of SARS-CoV-1 were similar (from 103.4 to 100.7 TCID50 per milliliter after 72 hours on plastic and from 103.6 to 100.6 TCID50 per milliliter after 48 hours on stainless steel). On copper, no viable SARS-CoV-2 was measured after 4 hours and no viable SARS-CoV-1 was measured after 8 hours. On cardboard, no viable SARS-CoV-2 was measured after 24 hours and no viable SARS-CoV-1 was measured after 8 hours (Figure 1A). Both viruses had an exponential decay in virus titer across all experimental conditions, as indicated by a linear decrease in the log10TCID50 per liter of air or milliliter of medium over time (Figure 1B). The half-lives of SARS-CoV-2 and SARS-CoV-1 were similar in aerosols, with median estimates of approximately 1.1 to 1.2 hours and 95% credible intervals of 0.64 to 2.64 for SARS-CoV-2 and 0.78 to 2.43 for SARS-CoV-1 (Figure 1C, and Table S1 in the Supplementary Appendix). The half-lives of the two viruses were also similar on copper. On cardboard, the half-life of SARS-CoV-2 was longer than that of SARS-CoV-1. The longest viability of both viruses was on stainless steel and plastic; the estimated median half-life of SARS-CoV-2 was approximately 5.6 hours on stainless steel and 6.8 hours on plastic (Figure 1C). Estimated differences in the half-lives of the two viruses were small except for those on cardboard (Figure 1C). Individual replicate data were noticeably “noisier” (i.e., there was more variation in the experiment, resulting in a larger standard error) for cardboard than for other surfaces (Fig. S1 through S5), so we advise caution in interpreting this result. We found that the stability of SARS-CoV-2 was similar to that of SARS-CoV-1 under the experimental circumstances tested. This indicates that differences in the epidemiologic characteristics of these viruses probably arise from other factors, including high viral loads in the upper respiratory tract and the potential for persons infected with SARS-CoV-2 to shed and transmit the virus while asymptomatic. 3,4 Our results indicate that aerosol and fomite transmission of SARS-CoV-2 is plausible, since the virus can remain viable and infectious in aerosols for hours and on surfaces up to days (depending on the inoculum shed). These findings echo those with SARS-CoV-1, in which these forms of transmission were associated with nosocomial spread and super-spreading events, 5 and they provide information for pandemic mitigation efforts.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Prevalence of comorbidities and its effects in patients infected with SARS-CoV-2: a systematic review and meta-analysis

            Highlights • COVID -19 cases are now confirmed in multiple countries. • Assessed the prevalence of comorbidities in infected patients. • Comorbidities are risk factors for severe compared with non-severe patients. • Help the health sector guide vulnerable populations and assess the risk of deterioration.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              COVID-19 and the cardiovascular system

              Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infects host cells through ACE2 receptors, leading to coronavirus disease (COVID-19)-related pneumonia, while also causing acute myocardial injury and chronic damage to the cardiovascular system. Therefore, particular attention should be given to cardiovascular protection during treatment for COVID-19.
                Bookmark

                Author and article information

                Contributors
                Journal
                Am J Med
                Am. J. Med
                The American Journal of Medicine
                Published by Elsevier Inc.
                0002-9343
                1555-7162
                19 June 2020
                19 June 2020
                Affiliations
                [a ]Department of Medicine, University of California San Diego, La Jolla, CA
                [b ]Division of Cardiology, Mitsui Memorial Hospital, Tokyo, Japan
                [c ]Division of Infectious Diseases, University of California San Diego, La Jolla, CA
                [d ]Division of Cardiovascular Medicine, University of California San Diego, La Jolla, CA
                [e ]University of California Berkeley, Berkeley, CA
                [f ]Division of Infectious Diseases, City of Hope National Medical Center, Duarte, CA
                [g ]Division of Infectious Diseases, Emory University, Atlanta, GA
                Author notes
                [* ]Corresponding Author: Rajiv S. Vasudevan, University of California San Diego, School of Medicine 9500 Gilman Dr, La Jolla, CA 92093. Phone: (650)–714-7908 rvasudev@ 123456health.ucsd.edu
                Article
                S0002-9343(20)30508-8
                10.1016/j.amjmed.2020.05.018
                7303610
                32569591
                d43d4788-2036-4cd6-81d3-23904cd0d90b
                © 2020 Published by Elsevier Inc.

                Since January 2020 Elsevier has created a COVID-19 resource centre with free information in English and Mandarin on the novel coronavirus COVID-19. The COVID-19 resource centre is hosted on Elsevier Connect, the company's public news and information website. Elsevier hereby grants permission to make all its COVID-19-related research that is available on the COVID-19 resource centre - including this research content - immediately available in PubMed Central and other publicly funded repositories, such as the WHO COVID database with rights for unrestricted research re-use and analyses in any form or by any means with acknowledgement of the original source. These permissions are granted for free by Elsevier for as long as the COVID-19 resource centre remains active.

                History
                Categories
                Article

                stethoscope,covid-19,advancement
                stethoscope, covid-19, advancement

                Comments

                Comment on this article