28
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: not found

      Accuracy of 64-slice CT angiography for the detection of functionally relevant coronary stenoses as assessed with myocardial perfusion SPECT.

      European Journal of Nuclear Medicine and Molecular Imaging
      Adult, Aged, Aged, 80 and over, Coronary Angiography, methods, Coronary Artery Disease, diagnosis, pathology, Coronary Stenosis, Coronary Vessels, Female, Humans, Male, Middle Aged, Myocardium, Organophosphorus Compounds, pharmacology, Organotechnetium Compounds, Perfusion, Prospective Studies, Tomography, Emission-Computed, Single-Photon, Tomography, X-Ray Computed

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          CT angiography (CTA) offers a valuable alternative for the diagnosis of CAD but its value in the detection of functionally relevant coronary stenoses remains uncertain. We prospectively compared the accuracy of 64-slice CTA with that of myocardial perfusion imaging (MPI) using (99m)Tc-tetrofosmin-SPECT as the gold standard for the detection of functionally relevant coronary artery disease (CAD). MPI and 64-slice CT were performed in 100 consecutive patients. CTA lesions were analysed quantitatively and area stenoses > or =50% and > or =75% were compared with the MPI findings. In 23 patients, MPI perfusion defects were found (12 reversible, 13 fixed). A total of 399 coronary arteries and 1,386 segments was analysed. Eighty-four segments (6.1%) in 23 coronary arteries (5.8%) of nine patients (9.0%) were excluded owing to insufficient image quality. In the remaining 1,302 segments, quantitative CTA revealed stenoses > or =50% in 57 of 376 coronary arteries (15.2%) and stenoses > or =75% in 32 (8.5%) coronary arteries. Using a cut-off at > or =75% area stenosis, CTA yielded the following sensitivity, specificity, negative (NPV) and positive predictive value (PPV), and accuracy for the detection of any (fixed and reversible) MPI defect: by patient, 75%, 90%, 93%, 68% and 87%, respectively; by artery, 76%, 95%, 99%, 50% and 94%, respectively. Sixty-four-slice CTA is a reliable tool to rule out functionally relevant CAD in a non-selected population with an intermediate pretest likelihood of disease. However, an abnormal CTA is a poor predictor of ischaemia.

          Related collections

          Author and article information

          Comments

          Comment on this article