          Abstract

          The Low Frequency Instrument on board the PLANCK satellite is designed to give the most accurate map ever of the CMB anisotropy of the whole sky over a broad frequency band spanning 27 to 77 GHz. It is made of an array of 22 pseudo-correlation radiometers, composed of 11 actively cooled (20 K) Front End Modules (FEMs), and 11 Back End Modules (BEMs) at 300K. The connection between the two parts is made with rectangular Wave Guides. Considerations of different nature (thermal, electromagnetic and mechanical), imposed stringent requirements on the WGs characteristics and drove their design. From the thermal point of view, the WG should guarantee good insulation between the FEM and the BEM sections to avoid overloading the cryocooler. On the other hand it is essential that the signals do not undergo excessive attenuation through the WG. Finally, given the different positions of the FEM modules behind the focal surface and the mechanical constraints given by the surrounding structures, different mechanical designs were necessary. A composite configuration of Stainless Steel and Copper was selected to satisfy all the requirements. Given the complex shape and the considerable length (about 1.5-2 m), manufacturing and testing the WGs was a challenge. This work deals with the development of the LFI WGs, including the choice of the final configuration and of the fabrication process. It also describes the testing procedure adopted to fully characterize these components from the electromagnetic point of view and the space qualification process they underwent. Results obtained during the test campaign are reported and compared with the stringent requirements. The performance of the LFI WGs is in line with requirements, and the WGs were successfully space qualified.

          Related collections

          Most cited references1

          • Record: found
          • Abstract: not found
          • Article: not found

          Effect of cable length in vector measurements of very long millimeter-wave components

            Bookmark

            Author and article information

            Journal
            2010-01-26
            Article
            10.1088/1748-0221/4/12/T12007
            1001.4711
            e04364f9-fb4e-4c8a-9747-1dc0279f3615

            http://arxiv.org/licenses/nonexclusive-distrib/1.0/

            History
            Custom metadata
            2009 JINST 4 T12007
            this paper is part of the Prelaunch status LFI papers published on JINST: http://www.iop.org/EJ/journal/-page=extra.proc5/jinst
            astro-ph.IM

            Instrumentation & Methods for astrophysics
            Instrumentation & Methods for astrophysics

            Comments

            Comment on this article