      Laser Scribed Graphene Biosensor for Detection of Biogenic Amines in Food Samples Using Locally Sourced Materials

      research-article

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          In foods, high levels of biogenic amines (BA) are the result of microbial metabolism that could be affected by temperatures and storage conditions. Thus, the level of BA is commonly used as an indicator of food safety and quality. This manuscript outlines the development of laser scribed graphene electrodes, with locally sourced materials, for reagent-free food safety biosensing. To fabricate the biosensors, the graphene surface was functionalized with copper microparticles and diamine oxidase, purchased from a local supermarket; and then compared to biosensors fabricated with analytical grade materials. The amperometric biosensor exhibits good electrochemical performance, with an average histamine sensitivity of 23.3 µA/mM, a lower detection limit of 11.6 µM, and a response time of 7.3 s, showing similar performance to biosensors constructed from analytical grade materials. We demonstrated the application of the biosensor by testing total BA concentration in fish paste samples subjected to fermentation with lactic acid bacteria. Biogenic amines concentrations prior to lactic acid fermentation were below the detection limit of the biosensor, while concentration after fermentation was 19.24 ± 8.21 mg histamine/kg, confirming that the sensor was selective in a complex food matrix. The low-cost, rapid, and accurate device is a promising tool for biogenic amine estimation in food samples, particularly in situations where standard laboratory techniques are unavailable, or are cost prohibitive. This biosensor can be used for screening food samples, potentially limiting food waste, while reducing chances of foodborne outbreaks.

          Related collections

          Most cited references52

          • Record: found
          • Abstract: found
          • Article: not found

          Laser-induced porous graphene films from commercial polymers

          Synthesis and patterning of carbon nanomaterials cost effectively is a challenge in electronic and energy storage devices. Here report a one-step, scalable approach for producing and patterning porous graphene films with 3-dimensional networks from commercial polymer films using a CO2 infrared laser. The sp3-carbon atoms are photothermally converted to sp2-carbon atoms by pulsed laser irradiation. The resulting laser-induced graphene (LIG) exhibits high electrical conductivity. The LIG can be readily patterned to interdigitated electrodes for in-plane microsupercapacitors with specific capacitances of >4 mF·cm−2 and power densities of ~9 mW·cm−2. Theoretical calculations partially suggest that enhanced capacitance may result from LIG’s unusual ultra-polycrystalline lattice of pentagon-heptagon structures. Combined with the advantage of one-step processing of LIG in air from commercial polymer sheets, which would allow the employment of a roll-to-roll manufacturing process, this technique provides a rapid route to polymer-written electronic and energy storage devices.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Biogenic amines: their importance in foods.

            Biogenic amines are important nitrogen compounds of biological importance in vegetable, microbial and animal cells. They can be detected in both raw and processed foods. In food microbiology they have sometimes been related to spoilage and fermentation processes. Some toxicological characteristics and outbreaks of food poisoning are associated with histamine and tyramine. Secondary amines may undergo nitrosation and form nitrosamines. A better knowledge of the factors controlling their formation is necessary in order to improve the quality and safety of food.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Atomic and electronic structure of graphene-oxide.

              We elucidate the atomic and electronic structure of graphene oxide (GO) using annular dark field imaging of single and multilayer sheets and electron energy loss spectroscopy for measuring the fine structure of C and O K-edges in a scanning transmission electron microscope. Partial density of states and electronic plasma excitations are also measured for these GO sheets showing unusual pi* + sigma* excitation at 19 eV. The results of this detailed analysis reveal that the GO is rough with an average surface roughness of 0.6 nm and the structure is predominantly amorphous due to distortions from sp3 C-O bonds. Around 40% sp3 bonding was found to be present in these sheets with measured O/C ratio of 1:5. These sp2 to sp3 bond modifications due to oxidation are also supported by ab initio calculations
                Bookmark

                Author and article information

                Journal
                Biosensors (Basel)
                Biosensors (Basel)
                biosensors
                Biosensors
                MDPI
                2079-6374
                24 April 2018
                June 2018
                : 8
                : 2
                : 42
                Affiliations
                [1 ]Department of Food Engineering, Universidad del Valle, Cali 760032, Colombia; laksmi.patino@ 123456correounivalle.edu.co (L.P.); connie.mendez@ 123456correounivalle.edu.co (C.M.)
                [2 ]Department of Biological and Agricultural Engineering, Texas A&M University, College Station, TX 77843, USA; daoliveira@ 123456tamu.edu
                [3 ]Department of Biology, Universidad del Valle, Cali 760032, Colombia; albamarina.torres@ 123456gmail.com
                [4 ]Department of Mechanical Engineering, Iowa State University, Ames, IA 50011, USA; carmen@ 123456iastate.edu
                [5 ]Department of Agricultural and Biological Engineering, Institute of Food and Agricultural Sciences, University of Florida, Gainesville, FL 32611, USA; emclamore@ 123456ufl.edu
                Author notes
                [* ]Correspondence: vanegas.diana@ 123456correounivalle.edu.co ; Tel.: +57-315-482-2602
                Author information
                https://orcid.org/0000-0003-0095-6478
                https://orcid.org/0000-0002-1662-7372
                Article
                biosensors-08-00042
                10.3390/bios8020042
                6023090
                29695046
                eebfbed3-982d-4f1e-ae7e-663720765c0f
                © 2018 by the authors.

                Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license ( http://creativecommons.org/licenses/by/4.0/).

                History
                : 06 February 2018
                : 19 April 2018
                Categories
                Article

                biogenic amines,laser scribed graphene,diamine oxidase,disposable sensor,food quality,risk assessment,planetary health

                Comments

                Comment on this article