      Single-ensemble-based eigen-processing methods for color flow imaging - Part I. The Hankel-SVD filter

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Because of their adaptability to the slow-time signal contents, eigen-based filters have shown potential in improving the flow detection performance of color flow images. This paper proposes a new eigen-based filter called the Hankel-SVD filter that is intended to process each slowtime ensemble individually. The new filter is derived using the notion of principal Hankel component analysis, and it achieves clutter suppression by retaining only the principal components whose order is greater than the clutter eigen-space dimension estimated from a frequency based analysis algorithm. To assess its efficacy, the Hankel-SVD filter was first applied to synthetic slow-time data (ensemble size: 10) simulated from two different sets of flow parameters that model: 1) arterial imaging (blood velocity: 0 to 38.5 cm/s, tissue motion: up to 2 mm/s, transmit frequency: 5 MHz, pulse repetition period: 0.4 ms) and 2) deep vessel imaging (blood velocity: 0 to 19.2 cm/s, tissue motion: up to 2 cm/s, transmit frequency: 2 MHz, pulse repetition period: 2.0 ms). In the simulation analysis, the post-filter clutter-to- blood signal ratio (CBR) was computed as a function of blood velocity. Results show that for the same effective stopband size (50 Hz), the Hankel-SVD filter has a narrower transition region in the post-filter CBR curve than that of another type of adaptive filter called the clutter-downmixing filter. The practical efficacy of the proposed filter was tested by application to in vivo color flow data obtained from the human carotid arteries (transmit frequency: 4 MHz, pulse repetition period: 0.333 ms, ensemble size: 10). The resulting power images show that the Hankel-SVD filter can better distinguish between blood and moving-tissue regions (about 9 dB separation in power) than the clutter-downmixing filter and a fixed-rank multi ensemble-based eigen-filter (which showed a 2 to 3 dB separation).

          Related collections

          Most cited references18

          • Record: found
          • Abstract: not found
          • Conference Proceedings: not found

          Real-Time Two-Dimensional Blood Flow Imaging Using an Autocorrelation Technique

            Bookmark
            • Record: found
            • Abstract: not found
            • Article: not found

            Clutter filter design for ultrasound color flow imaging

              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              High speed, wide velocity dynamic range Doppler optical coherence tomography (Part I): System design, signal processing, and performance.

              Improvements in real-time Doppler optical coherence tomography (DOCT), acquiring up to 32 frames per second at 250 x 512 pixels per image, are reported using signal processing techniques commonly employed in Doppler ultrasound imaging. The ability to measure a wide range of flow velocities, ranging from less than 20 microm/s to more than 10 cm/s, is demonstrated using an 1.3 microm DOCT system with flow phantoms in steady and pulsatile flow conditions. Based on full implementation of a coherent demodulator, four different modes of flow visualization are demonstrated: color Doppler, velocity variance, Doppler spectrum, and power Doppler. The performance of the former two, which are computationally suitable for real-time imaging, are analyzed in detail under various signal-to-noise and frame-rate conditions. The results serve as a guideline for choosing appropriate imaging parameters for detecting in vivo blood flow.
                Bookmark

                Author and article information

                Journal
                IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control
                IEEE Trans. Ultrason., Ferroelect., Freq. Contr.
                Institute of Electrical and Electronics Engineers (IEEE)
                0885-3010
                March 2008
                March 2008
                : 55
                : 3
                : 559-572
                Article
                10.1109/TUFFC.2008.682
                18407847
                f3919022-f5a1-495e-87ad-29a8df614f81
                © 2008
                History

                Comments

                Comment on this article