11
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: found
      Is Open Access

      Posture-induced changes in intraocular pressure after ab externo XEN45 gel-stent implantation in patients with primary open-angle glaucoma

      research-article

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Background

          To investigate posture-induced changes in intraocular pressure (IOP) after ab externo XEN45 Gel-Stent implantation in patients with medically uncontrolled primary open-angle glaucoma (POAG).

          Methods

          This prospective study included thirty-two eyes with POAG that underwent XEN45 Gel-Stent implantation as a standalone procedure using an ab externo approach at Chonnam National University Hospital. IOP was measured sequentially in the sitting position, supine position, and lateral decubitus position (LDP) before and at 1, 2, 3, and 6 months after surgery using an iCare IC200 rebound tonometer. In the LDP, the eye with XEN45 Gel-Stent implantation was in the dependent position.

          Results

          IOP at each position was significantly reduced after XEN45 Gel-Stent implantation. Posture-induced changes in IOP were maintained during the follow-up. The range of postural IOP changes was reduced at 1 month; however, no significant change was observed after that point compared with baseline levels.

          Conclusions

          A XEN45 Gel-Stent inserted using the ab externo approach can reduce IOP in various body positions, but seems to have limited effects on posture-induced changes in IOP in patients with POAG.

          Related collections

          Most cited references49

          • Record: found
          • Abstract: found
          • Article: not found

          Global prevalence of glaucoma and projections of glaucoma burden through 2040: a systematic review and meta-analysis.

          Glaucoma is the leading cause of global irreversible blindness. Present estimates of global glaucoma prevalence are not up-to-date and focused mainly on European ancestry populations. We systematically examined the global prevalence of primary open-angle glaucoma (POAG) and primary angle-closure glaucoma (PACG), and projected the number of affected people in 2020 and 2040. Systematic review and meta-analysis. Data from 50 population-based studies (3770 POAG cases among 140,496 examined individuals and 786 PACG cases among 112 398 examined individuals). We searched PubMed, Medline, and Web of Science for population-based studies of glaucoma prevalence published up to March 25, 2013. Hierarchical Bayesian approach was used to estimate the pooled glaucoma prevalence of the population aged 40-80 years along with 95% credible intervals (CrIs). Projections of glaucoma were estimated based on the United Nations World Population Prospects. Bayesian meta-regression models were performed to assess the association between the prevalence of POAG and the relevant factors. Prevalence and projection numbers of glaucoma cases. The global prevalence of glaucoma for population aged 40-80 years is 3.54% (95% CrI, 2.09-5.82). The prevalence of POAG is highest in Africa (4.20%; 95% CrI, 2.08-7.35), and the prevalence of PACG is highest in Asia (1.09%; 95% CrI, 0.43-2.32). In 2013, the number of people (aged 40-80 years) with glaucoma worldwide was estimated to be 64.3 million, increasing to 76.0 million in 2020 and 111.8 million in 2040. In the Bayesian meta-regression model, men were more likely to have POAG than women (odds ratio [OR], 1.36; 95% CrI, 1.23-1.52), and after adjusting for age, gender, habitation type, response rate, and year of study, people of African ancestry were more likely to have POAG than people of European ancestry (OR, 2.80; 95% CrI, 1.83-4.06), and people living in urban areas were more likely to have POAG than those in rural areas (OR, 1.58; 95% CrI, 1.19-2.04). The number of people with glaucoma worldwide will increase to 111.8 million in 2040, disproportionally affecting people residing in Asia and Africa. These estimates are important in guiding the designs of glaucoma screening, treatment, and related public health strategies. Copyright © 2014 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: found
            Is Open Access

            Minimally-invasive glaucoma surgeries (MIGS) for open angle glaucoma: A systematic review and meta-analysis

            Background MIGS have been developed as a surgical alternative for glaucomatous patients. Purpose To analyze the change in intraocular pressure (IOP) and glaucoma medications using different MIGS devices (Trabectome, iStent, Excimer Laser Trabeculotomy (ELT), iStent Supra, CyPass, XEN, Hydrus, Fugo Blade, Ab interno canaloplasty, Goniscopy-assisted transluminal trabeculotomy) as a solo procedure or in association with phacoemulsification. Methods Randomized control trials (RCT) and non-RCT (non randomized comparative studies, NRS, and before-after studies) were included. Studies with at least one year of follow-up in patients affected by primary open angle glaucoma, pseudoexfoliative glaucoma or pigmentary glaucoma were considered. Risk of Bias assessment was performed using the Cochrane Risk of Bias and the ROBINS-I tools. The main outcome was the effect of MIGS devices compared to medical therapy, cataract surgery, other glaucoma surgeries and other MIGS on both IOP and use of glaucoma medications 12 months after surgery. Outcomes measures were the mean difference in the change of IOP and glaucoma medication compared to baseline at one and two years and all ocular adverse events. The current meta-analysis is registered on PROSPERO (reference n° CRD42016037280). Results Over a total of 3,069 studies, nine RCT and 21 case series with a total of 2.928 eyes were included. Main concerns about risk of bias in RCTs were lack of blinding, allocation concealment and attrition bias while in non-RCTs they were represented by patients’ selection, masking of participants and co-intervention management. Limited evidence was found based on both RCTs and non RCTs that compared MIGS surgery with medical therapy or other MIGS. In before-after series, MIGS surgery seemed effective in lowering both IOP and glaucoma drug use. MIGS showed a good safety profile: IOP spikes were the most frequent complications and no cases of infection or BCVA loss due to glaucoma were reported. Conclusions Although MIGS seem efficient in the reduction of the IOP and glaucoma medication and show good safety profile, this evidence is mainly derived from non-comparative studies and further, good quality RCTs are warranted.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Predictive factors for glaucomatous visual field progression in the Advanced Glaucoma Intervention Study.

              To investigate the risk factors associated with visual field (VF) progression in the Advanced Glaucoma Intervention Study (AGIS) with pointwise linear regression (PLR) analysis of serial VFs. Prospective, multicenter, randomized clinical trial. Five hundred nine eyes of 401 patients from the AGIS with a baseline VF score of or=7 VF examinations, and >or=3 years of follow-up were selected. Visual field progression. This is a cohort study of patients enrolled in a prospective randomized clinical trial (AGIS). Worsening of a test location on PLR analysis was defined as a change of threshold sensitivity of >or=1.00 decibels a year, with P
                Bookmark

                Author and article information

                Contributors
                exo70@naver.com
                Journal
                BMC Ophthalmol
                BMC Ophthalmol
                BMC Ophthalmology
                BioMed Central (London )
                1471-2415
                29 December 2022
                29 December 2022
                2022
                : 22
                : 516
                Affiliations
                GRID grid.411597.f, ISNI 0000 0004 0647 2471, Department of Ophthalmology, , Chonnam National University Medical School and Hospital, ; 42 Jebong-ro, Dong-gu, Gwangju, 61469 South Korea
                Article
                2760
                10.1186/s12886-022-02760-w
                9801584
                36581827
                f93a4662-4af9-436c-91bd-8f80707a7306
                © The Author(s) 2022

                Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver ( http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

                History
                : 4 November 2022
                : 28 December 2022
                Funding
                Funded by: FundRef http://dx.doi.org/10.13039/501100003625, Ministry of Health and Welfare;
                Award ID: HI19C0481
                Award ID: HI19C0481
                Award ID: HI19C0481
                Award ID: HI19C0481
                Award ID: HI19C0481
                Categories
                Research
                Custom metadata
                © The Author(s) 2022

                Ophthalmology & Optometry
                xen45 gel-stent,ab externo,posture-induced changes in iop,rebound tonometry

                Comments

                Comment on this article