21
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: not found
      • Article: not found

      Noninvasive single-beat determination of left ventricular end-systolic elastance in humans

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          The goal of this study was to develop and validate a method to estimate left ventricular end-systolic elastance (E(es)) in humans from noninvasive single-beat parameters. Left ventricular end-systolic elastance is a major determinant of cardiac systolic function and ventricular-arterial interaction. However, its use in heart failure assessment and management is limited by lack of a simple means to measure it noninvasively. This study presents a new noninvasive method and validates it against invasively measured E(es). Left ventricular end-systolic elastance was calculated by a modified single-beat method employing systolic (P(s)) and diastolic (P(d)) arm-cuff pressures, echo-Doppler stroke volume (SV), echo-derived ejection fraction (EF) and an estimated normalized ventricular elastance at arterial end-diastole (E(Nd)): E(es(sb)) = [P(d) - (E(Nd(est)) x P(s) x 0.9)[/(E(Nd(est)) x SV). The E(Nd) was estimated from a group-averaged value adjusted for individual contractile/loading effects; E(es(sb)) estimates were compared with invasively measured values in 43 patients with varying cardiovascular disorders, with additional data recorded after inotropic stimulation (n = 18, dobutamine 5 to 10 microg/kg per min). Investigators performing noninvasive analysis were blinded to the invasive results. Combined baseline and dobutamine-stimulated E(es) ranged 0.4 to 8.4 mm Hg/ml and was well predicted by E(es(sb)) over the full range: E(es) = 0.86 x E(es(sb)) + 0.40 (r = 0.91, SEE = 0.64, p < 0.00001, n = 72). Absolute change in E(es(sb)) before and after dobutamine also correlated well with invasive measures: E(es(sb)): DeltaE(es) = 0.86 x DeltaE(es(sb)) + 0.67 (r = 0.88, p < 0.00001). Repeated measures of E(es(sb)) over two months in a separate group of patients (n = 7) yielded a coefficient of variation of 20.3 +/- 6%. The E(es) can be reliably estimated from simple noninvasive measurements. This approach should broaden the clinical applicability of this useful parameter for assessing systolic function, therapeutic response and ventricular-arterial interaction.

          Related collections

          Author and article information

          Journal
          Journal of the American College of Cardiology
          Journal of the American College of Cardiology
          Elsevier BV
          07351097
          December 2001
          December 2001
          : 38
          : 7
          : 2028-2034
          Article
          10.1016/S0735-1097(01)01651-5
          11738311
          fd82a4c7-81fc-4d02-adc1-71e934f5712d
          © 2001

          https://www.elsevier.com/tdm/userlicense/1.0/

          https://www.elsevier.com/open-access/userlicense/1.0/

          History

          Comments

          Comment on this article